Conventional fire alarm systems
Talentum UV/IR2 Ex d Flameproof Flame Detector 16521
Brand
Talentum
View Product
→
AZEIDK Solutions
Integrated Engineering Solutions for Safer Facilities
Fire protection, low current systems, and electromechanical solutions.
Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Civil Defense, Salamah & Balady TransactionsSubmitting and following up Salamah licences (instant and non-instant) and Balady requests, preparing technical reports and closing inspection notes→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
The Talentum IR3 Ex d flame detector (model 16519) by FFE, UK, is the flameproof version of the IR3, designed to protect hazardous areas where open fires may be expected. It detects almost all flames, from hydrocarbon fires with 4.3 µm emissions to invisible fires such as hydrogen, and responds to flickering infrared radiation (1 to 15 Hz) even if the lens is contaminated by oil, dust, water, vapour or ice.
Three IR sensors discriminate between flames and spurious sources of radiation, and filters plus signal processing avoid false alarms from flickering sunlight. Relay contacts or a 4-20 mA signal are selectable as standard.
| Model | Talentum IR3 Ex d: EN version 16519-00, FM version 16519-20 |
|---|---|
| Detection technology | Three infrared sensors (IR3), operating wavelength 1.0 to 2.7 µm |
| Detection range | High (Class 1): 0.1 m² n-heptane fire at 25 m. Low (Class 3): 0.1 m² n-heptane at 12 m |
| Field of view | 90° minimum cone (viewing angle not to exceed ±20° to meet EN 54-10) |
| Outputs | Programmable relays (latching or non-latching) or 4-20 mA; relay rating 0.75 A, 48 V DC, 30 W (resistive loads only) |
| Supply voltage | 14 to 30 V DC |
| Current consumption | Quiescent 3, 4 or 8 mA; alarm 9, 20 or 28 mA depending on mode |
| Housing | Flameproof (Ex d), copper free aluminium alloy, red, 158 x 149 x 137 mm, 2.3 kg |
| Cable entries | 3 x 20 mm, wiring 1.0 to 4.0 mm² |
| Ingress protection | IP66 |
| Operating temperature | EN: -10 to +55 °C; FM: -20 to +60 °C; relative humidity 95% non-condensing |
| Approvals | EN 54-10, LPCB, ATEX and IECEx |
| Accessories | Adjustable mounting bracket 07127-00, stainless steel Ex d weather shield 07279-00, Ex d air purge 12555-00, Talentum Test Torch 1800-101 |
Ex d is the flameproof type of protection: the enclosure is built to contain an internal ignition so it does not spread to the surrounding flammable atmosphere. That is why it is used in classified hazardous areas, and this detector carries ATEX and IECEx certification.
Same detection technology and 25 m range, but the 16519 has a red flameproof aluminium IP66 housing with three cable entries, while the 16589 has a blue zinc IP65 housing for ordinary areas.
It has built-in automatic and manual test and can be checked with the Talentum Test Torch 1800-101. Follow the Ex d installation guide before opening the housing in a hazardous area.
View the product’s full specifications and technical information in the official catalogue.
Explore more products available in this category.