Conventional fire alarm systems
FP Range 2-Zone Extender Card, FF387Z-2
Brand
Context Plus
View Product
→
AZEIDK Solutions
Integrated Engineering Solutions for Safer Facilities
Fire protection, low current systems, and electromechanical solutions.
Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
The Context Plus Series 65E conventional smoke detectors are designed for use in conventional fire alarm systems and are available in optical and ionisation sensing versions.
The Series 65E range uses proven detection technologies and operates over a wide voltage range of 9 to 33V DC.
Each detector includes an LED that flashes during standby and illuminates red when the detector enters an alarm condition.
Available Models:
• 55000-316IMC — Optical smoke detector using photo-electric detection of light scattered by smoke particles.
• 55000-216IMC — Ionisation smoke detector.
Key Features:
• Conventional smoke detectors from the Series 65E range.
• EN54-compliant range.
• Available with optical or ionisation sensing technology.
• Wide operating voltage range from 9 to 33V DC.
• Two-wire polarity-insensitive supply connection.
• Flashing LED during standby.
• Red LED alarm indication.
• Status indicator switches off during a fault condition.
• Remote indicator connection through the R- terminal.
• Proven detection performance.
• Optical detector performance is unaffected by wind speed according to the catalogue.
• Flame-retardant polycarbonate housing.
• Nickel-plated stainless-steel terminals.
• IP23D protection rating.
• Suitable for commercial, administrative and residential conventional fire alarm systems.
Technical Specifications:
• Supply voltage: 9 to 33V DC.
• Power-up surge current: 115µA at 24V DC.
• Quiescent current: 30 to 50µA at 24V DC.
• Alarm current: 52mA at 24V DC.
• Alarm LED current: 4mA.
• Operating temperature: -20 to 60°C.
• Humidity: 0% to 95%, without condensation or icing.
• IP rating: IP23D.
Compatible Bases and Accessories:
• 45681-200IMC — Standard Series 65E detector base.
• 45681-245 — Standard relay base.
• BF318 — Remote LED detector indicator.
View the product’s full specifications and technical information in the official catalogue.