Conventional fire alarm systems
FP Range 2-Zone Extender Card, FF387Z-2
Brand
Context Plus
View Product
→
AZEIDK Solutions
Integrated Engineering Solutions for Safer Facilities
Fire protection, low current systems, and electromechanical solutions.
Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
The Context Plus FP conventional fire alarm panel range is available in capacities from 1 to 14 zones, providing suitable options for small and medium-sized buildings and facilities.
The panels are supplied in robust metal enclosures with lift-off lids for easier first-fix installation and maintenance. They offer broad compatibility with conventional smoke and heat detectors.
The range includes non-expandable 1, 2, 4 and 8-zone panels, together with a 4-zone panel expandable to 6 zones and an 8-zone panel expandable to 14 zones.
Available Models:
• FF380/CON — 1-zone non-expandable conventional fire panel, supplied with two 1.2Ah batteries.
• FF382/CON — 2-zone non-expandable conventional fire panel, supplied with two 1.2Ah batteries.
• FF384/CON — 4-zone non-expandable conventional fire panel, supplied with two 1.2Ah batteries.
• FF388/CON — 8-zone non-expandable conventional fire panel, supplied with two 2.3Ah batteries.
• FF384-2/CON — 4-zone fire alarm panel expandable to 6 zones; batteries are not included.
• FF388-2/CON — 8-zone fire alarm panel expandable to 14 zones; batteries are not included.
Key Features:
• Designed to comply with BS 5839 Part 4.
• Robust metal enclosure with a lift-off lid.
• Two conventional sounder circuits.
• Built-in 24V power supply and battery charger.
• Optional detector head removal monitoring.
• Separate indicators for open-circuit and short-circuit faults.
• Separate indications for sounder, battery and power-supply faults.
• Non-latching class-change sounder input.
• Fire and fault outputs available through an optional expansion loom.
• Fault buzzer mute facility.
• Internal space for the rated capacity of VRLA batteries.
• Selectable short-circuit-equals-fire facility on a zone-by-zone basis, suitable for retro installations.
• One-person walk test and zone isolation facility, except on the FF380/CON.
• Ancillary connections for repeater panels and additional modules, except on the FF380/CON.
• Compatible with Context Plus Series 65A, Series 65E and ActiV conventional detectors.
Expansion and repeater accessories for the FP range are listed as separate products within the same category.
View the product’s full specifications and technical information in the official catalogue.
Explore more products available in this category.