Conventional fire alarm systems
FP Range 2-Zone Extender Card, FF387Z-2
Brand
Context Plus
View Product
→
AZEIDK Solutions
Integrated Engineering Solutions for Safer Facilities
Fire protection, low current systems, and electromechanical solutions.
Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
The Context Plus Series 65A UL conventional smoke detectors are designed for use within conventional fire alarm systems and are available in optical and ionisation sensing versions.
Both models form part of the Series 65A range and operate over a wide voltage range of 9 to 33V DC. They include a red alarm LED and support connection to a remote detector indicator.
Available Models:
• 55000-326IMC — Photo-electric optical smoke detector with flashing LED.
• 55000-226IMC — Ionisation smoke detector with flashing LED.
Key Features:
• Conventional smoke detectors from the Series 65A range.
• UL Listed.
• Available with optical or ionisation sensing technology.
• Wide operating voltage range from 9 to 33V DC.
• Red LED alarm indication.
• Flashing LED during normal operation.
• Remote indicator connection.
• Designed for use with Series 65A detector bases.
• Lockable detector bases with no electronic components that could be damaged during installation.
• Suitable for conventional fire alarm systems in commercial, administrative and residential buildings.
Technical Specifications for Model 55000-326IMC:
• Supply voltage: 9 to 33V.
• Average standby current at 24V: 45µA.
• Average standby current at 9V: 40µA.
• Alarm current at 24V: 52mA.
• Alarm current at 9V: 17mA.
• Alarm indication: Red LED.
• Ambient temperature: 32 to 100°F.
• Remote output: R- current sink, limited to 17mA.
Compatible Bases and Accessories:
• 45681-200IMC — Standard Series 65A detector base.
• 45681-245 — Standard relay base.
• BF318 — Remote LED detector indicator.
View the product’s full specifications and technical information in the official catalogue.
Explore more products available in this category.