Talentum IR2 Dual IR Flame Detector 16581

Talentum IR2 flame detector by FFE (UK) with two infrared sensors for indoor areas. Detects hydrocarbon and hydrogen fires up to 25 m (EN 54-10 Class 1), selectable relay or 4-20 mA output, with LPCB and AFNOR certification.
Brand
Talentum IR2 flame detector 16581 by FFE

Product Details

Product Overview

The Talentum IR2 flame detector (model 16581) by FFE, UK, is designed to protect areas where open fires may be expected. It detects almost all flames, from hydrocarbon fires with 4.3 µm emissions to invisible fires such as hydrogen, and responds to flickering, low frequency (1 to 15 Hz) infrared radiation even if the lens is contaminated by oil, dust, water, vapour or ice.

Two IR sensors respond to different wavelengths to discriminate between flames and spurious sources of radiation, and filters plus signal processing avoid false alarms from flickering sunlight. The IR2 is specified for indoor areas and offers selectable relay contacts or a 4-20 mA signal as standard.

ModelTalentum IR2: EN version 16581-00, NF version 16581-04
Detection technologyTwo infrared sensors (IR2), operating wavelength 1.0 to 2.7 µm
Detection rangeHigh (Class 1): 0.1 m² n-heptane fire at 25 m. Low (Class 3): 0.1 m² n-heptane at 12 m
Field of view90° minimum cone (viewing angle not to exceed ±30° to meet EN 54-10)
OutputsProgrammable relays (latching or non-latching) or 4-20 mA; relay rating 0.75 A, 48 V DC, 30 W (resistive loads only)
Supply voltage14 to 30 V DC
Current consumptionQuiescent 3, 4 or 8 mA; alarm 9, 20 or 28 mA depending on relay or current loop mode
Power-up time2 seconds max.
HousingDie cast zinc alloy (ZA12), blue, 142 x 108 x 79 mm, 1.75 kg
Cable entries2 x 20 mm, wiring 1.0 to 4.0 mm²
Ingress protectionIP65
Operating temperature-10 to +55 °C; relative humidity 95% non-condensing
ApprovalsEN 54-10 with AFNOR and LPCB certification
AccessoriesAdjustable mounting bracket 07127-00, stainless steel weather shield 12545-00, Talentum Test Torch 1800-101, air purge kit 12556-00

Applications

  • Chemical plants and pharmaceutical production
  • Compressor stations and engine rooms
  • LNG and LPG production
  • Coal handling and waste recycling
  • Tunnels, spray booths and printing
  • Military and marine sites

FAQ

What is the difference between Talentum IR2 and IR3?

The IR2 uses two infrared sensors and its datasheet specifies it for indoor areas. The IR3 uses three sensors and is specified for indoor and outdoor areas. For an outdoor site exposed to sunlight, review the IR3 or UV/IR2.

Is there a flameproof version of the IR2?

Yes. The Talentum IR2 Ex d, model 16511, has a copper free aluminium IP66 housing with ATEX and IECEx certification for hazardous areas.

Can it connect to a conventional fire alarm panel?

Yes. The relay output wires into a conventional panel zone, or the 4-20 mA output can feed a control system. Wiring details are in the datasheet and user guide.

Technical Documents