TYCO TY-B Sprinklers: K2.8, K5.6 and K8.0 Upright and Pendent Models and How to Choose

TYCO TY-B Sprinklers: K2.8, K5.6 and K8.0 Upright and Pendent Models and How to Choose

TYCO TY-B sprinklers (Series TY-B) are standard response, standard coverage glass bulb sprinklers with a 5 mm bulb, offered as upright, pendent and recessed pendent heads in three K-factors: K2.8, K5.6 and K8.0. In Saudi Arabia AZEIDK supplies TYCO Series TY-B sprinklers. This guide reviews the series as described in TYCO datasheet TFP151 and how to choose between the models.

You will see what each model number means, why there are two K8.0 versions with different thread sizes, and what the installation team needs to fit the series correctly.

Key points

  • All TY-B models are standard response, standard coverage, with a 5 mm glass bulb.
  • K2.8: TY1151 upright, TY1251 pendent. K5.6: TY3151 upright, TY3251 pendent.
  • K8.0 with 3/4 in thread: TY4151 upright, TY4251 pendent. K8.0 with 1/2 in thread: TY4851 and TY4951 for retrofit of existing systems.
  • Recessed heads use the Style 10 (1/2 in) or Style 40 (3/4 in) escutcheon.
  • Maximum working pressure 175 psi, and 250 psi for some models under the UL listing per Table D.
In this article
  1. What are TYCO TY-B sprinklers?
  2. TYCO TY-B sprinkler models: full table
  3. Why is there a K8.0 with a 1/2 in thread?
  4. Choosing between K2.8, K5.6 and K8.0
  5. Recessed TY-B with Style 10 and Style 40 escutcheons
  6. Materials, finishes and approvals
  7. Installation instructions from the datasheet
  8. How AZEIDK helps
  9. FAQ
  10. Summary

What are TYCO TY-B sprinklers?

TYCO describes the series as decorative standard response, standard coverage spray sprinklers for light, ordinary or extra hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries and chemical plants. Standard coverage means spacing and area per head follow the normal tables of the standard, not extended coverage.

All heads in the series operate the same way: bulb liquid expands until the bulb breaks at its rating, the seal releases and water reaches the deflector. Models differ in K-factor, orientation and thread size. Because the whole series is standard response, it is not the choice where the design requires quick response heads.

TYCO TY-B sprinkler models: full table

Model (SIN)OrientationK-factorConnection
TY1151Upright2.81/2 in NPT
TY1251Pendent2.81/2 in NPT
TY3151Upright5.61/2 in NPT
TY3251Pendent or recessed5.61/2 in NPT
TY4151Upright8.03/4 in NPT
TY4251Pendent or recessed8.03/4 in NPT
TY4851Upright8.01/2 in NPT
TY4951Pendent8.01/2 in NPT

Metric K-factors per the datasheet: K2.8 = 40.3, K5.6 = 80.6 and K8.0 = 115.2 Lpm/bar½. ISO 7-1 threads can be supplied on special request.

Why is there a K8.0 with a 1/2 in thread?

The datasheet notes that NFPA 13 prohibits 1/2 in NPT sprinklers with K-factors greater than 5.6 in new construction, and that TY4851 and TY4951 are intended for retrofit in existing systems only. In practice, an existing building with 1/2 in drops may need a higher density after a change of use, and a larger K head can be fitted without replacing all fittings.

In a new project needing K8.0, TY4151 and TY4251 with 3/4 in threads are the right choice. This must show in the BOQ, since “K8.0 sprinkler” alone fits both. In Saudi Arabia SBC 801 and Civil Defense requirements are binding, with NFPA as a technical reference.

Choosing between K2.8, K5.6 and K8.0

  • K5.6: the most common factor in light and ordinary hazard areas such as offices, shops, hotels and car parks.
  • K8.0: more flow at the same pressure, used where the design needs a higher density, as in some higher ordinary or extra hazard areas per the calculations.
  • K2.8: a small orifice for limited applications the standard and design allow, not a general substitute for K5.6.

The final choice comes from hazard classification and hydraulic calculations. See sprinkler hazard classification and sprinkler head types and K-factor.

Recessed TY-B with Style 10 and Style 40 escutcheons

The recessed pendent is intended for finished ceilings and uses a two-piece escutcheon: Style 10 for 1/2 in models and Style 40 for 3/4 in models. It provides 1/2 in (12.7 mm) of recessed adjustment, or up to 3/4 in (19.1 mm) of total adjustment from the flush pendent position, which reduces how precisely drops must be cut.

The datasheet requires only the Style 10 or 40 escutcheon for recessed installations. Escutcheon finishes: white, grey aluminium, black, chrome and natural brass. For recessed vs concealed see recessed and extended coverage sprinklers.

Materials, finishes and approvals

  • Standard materials: bronze frame, brass/copper button, beryllium nickel sealing assembly with Teflon, bronze compression screw, copper deflector.
  • Poly-Stainless finish: L316 stainless steel button and compression screw, gold plated beryllium nickel sealing assembly, for corrosive atmospheres.
  • Intermediate level: the pendent can be used with the Model S2 shield as an intermediate level sprinkler.
  • Approvals: UL, C-UL, FM, LPCB, VdS and NYC, varying by model, temperature and finish in Tables A, B and C.

TYCO notes that corrosion resistant coatings passed the approval agencies’ tests but those tests do not represent every corrosive atmosphere, so suitability for the project environment should be reviewed. Temperature ratings in the tables: 57°C orange, 68°C red, 79°C yellow, 93°C green and 141°C blue.

Installation instructions from the datasheet

  • Never install a head with a cracked bulb or lost fluid. Held horizontally, a small air bubble should be visible in the bulb.
  • Torque for 1/2 in NPT heads: 7 to 14 lb-ft (9.5 to 19.0 N·m).
  • Torque for 3/4 in NPT heads: 10 to 20 lb-ft (13.4 to 26.8 N·m). Higher torque can distort the inlet and cause leakage.
  • Use the W-Type 6 wrench for standard heads and W-Type 7 for recessed heads.
  • After installation inspect wrench flats and frame arms, and repair any damaged wax coating on wax coated heads.

TYCO states the series must be installed and maintained per the datasheet, NFPA standards and the authority having jurisdiction, which in Saudi Arabia is Civil Defense.

How AZEIDK helps

AZEIDK reviews drawings, assigns the right TY-B model per area by K-factor, orientation, temperature and finish, prepares datasheets and listing tables for the submittal, and can deliver the work through its installation service. For other TYCO heads by application see selecting TYCO sprinklers for projects and TYCO in Saudi Arabia, and the full network under fire fighting systems.

FAQ

What are TYCO TY-B sprinklers?

A TYCO series of standard response, standard coverage sprinklers with a 5 mm bulb, in upright, pendent and recessed versions at K2.8, K5.6 and K8.0.

What is the difference between TY3151 and TY3251?

Both are K5.6 with 1/2 in thread. TY3151 is upright; TY3251 is pendent and can be recessed with a Style 10 escutcheon.

Are TY-B sprinklers quick response?

No, every model in the series is standard response. A quick response design needs a different model.

When are TY4851 or TY4951 used?

For retrofit in existing systems only, since NFPA 13 prohibits 1/2 in heads above K5.6 in new construction, as the datasheet notes.

What is the working pressure of TY-B sprinklers?

175 psi maximum, rising to 250 psi for some models under the UL listing only, per Table D of the datasheet.

What torque is used for TY-B sprinklers?

7 to 14 lb-ft for 1/2 in threads and 10 to 20 lb-ft for 3/4 in threads, using the W-Type 6 wrench.

Summary

TYCO TY-B is a broad standard response series that covers most light and ordinary hazard needs in commercial buildings. Specify the model number, not only the K-factor, separate K8.0 with 3/4 in threads for new work from 1/2 in threads for retrofit, and keep to the torque and wrench requirements on site.

Need TY-B sprinklers for your project? Send drawings or the BOQ with hazard classification and ceiling type, and we will send the matching models and datasheets for your submittal. Contact the AZEIDK team

References: TYCO Series TY-B, datasheet TFP151 (AZEIDK brand page) (Johnson Controls / TYCO), and the AZEIDK TY-B product page
Share this article