The Honeywell Farenhyt IFP-2100 is an intelligent addressable fire alarm control panel that starts with one built-in loop and expands to 2,100 points. It has eight Flexput circuits for notification or auxiliary power, a built-in digital communicator, and networking for up to 32 panels. AZEIDK supplies it in Saudi Arabia, and this guide covers its capacity, expansion and project fit, based on the datasheet published on the product page.
The panel is part of AZEIDK fire alarm systems. Product page: Honeywell Farenhyt IFP-2100.
Key points
- The built-in SLC supports 159 detectors and 159 modules on the IDP/SK protocol, or 127 Hochiki SD devices.
- Additional loops take the panel to 2,100 IDP/SK or 2,032 SD points.
- Eight Flexput circuits work as NACs or auxiliary power, up to 3 A per circuit and 9 A in total.
- Up to 32 panels can be networked over copper or fibre; the RFP-2100 is the version without a display.
- The datasheet states compliance with UL 864 10th Edition and UL 2572, a UL listing and FM approval.
Capacity: how many devices?
The panel ships with one signaling line circuit. Its capacity depends on the device protocol: 159 System Sensor IDP/SK detectors plus 159 modules, or 127 Hochiki SD devices. The datasheet is clear that IDP/SK and SD devices cannot be mixed in one system, so the protocol is fixed at the start.
For more capacity, the 6815 SLC expander (IDP/SK) or 5815XL (SD) adds loops up to 2,100 IDP/SK or 2,032 SD points. Programming offers 999 software zones and 999 output groups, with up to 63 SBUS devices such as remote annunciators and relay modules.
| Item | Datasheet value |
|---|---|
| Built-in SLC | 159 detectors + 159 modules (IDP/SK) or 127 devices (SD) |
| Maximum capacity | 2,100 points (IDP/SK) or 2,032 points (SD) |
| Output circuits | 8 Flexput, expandable |
| Relays | One fixed trouble relay and two programmable relays, Form C, 2.5 A at 27.4 VDC |
| Networking | Up to 32 panels |
| Standby / alarm current | 230 mA / 415 mA |
| Batteries | Cabinet holds two 18 Ah batteries; charger 17 to 55 Ah |
| Weight | 15 kg, red or black cabinet |
Flexput circuits: notification and auxiliary power
Instead of fixed sounder circuits, the panel provides eight Flexput circuits, each programmable as a notification appliance circuit or auxiliary power output. They run as eight Class B or four Class A circuits, with a maximum of 3 A per circuit and 9 A for all circuits, and a 4.7 kΩ end-of-line resistor for Class B NACs. Where more current is needed, the datasheet lists the 5496 power expander with four circuits and the RPS-1000 power supply with six Flexput circuits.
Load and standby battery calculations for these circuits are part of the design; see fire alarm battery calculation.
Networking and multi-building sites
The IFP-2100 networks up to 32 panels in two modes: several panels covering one large building, or panels in separate buildings. Connection is through the SK-NIC network card over copper, or over multi-mode (SK-FML) or single-mode (SK-FSL) fibre. Display-less RFP-2100 panels can join the network as long as at least one IFP-2100 is present. For when a panel network makes sense, see networked fire alarm panels.
Built-in communicator and remote monitoring
The panel includes a dual-technology DACT, IP and telephone line, with optional cellular reporting. It sends alarms, troubles and AC loss to a monitoring station. This is useful for facilities with a central control room or a contracted monitoring service, and its use is set by the design and project requirements.
Compatible detectors and modules
The datasheet lists compatible IDP and SK devices, including photoelectric smoke detectors, fixed and rate-of-rise heat detectors, multi-criteria detectors, reflected beam and duct detectors, a four-criteria fire and CO detector, monitor, control and isolator modules, and manual pull stations. It also lists compatibility with System Sensor SWIFT wireless devices. For the Farenhyt addressable CO detector that AZEIDK supplies, see addressable carbon monoxide detectors.
When the IFP-2100 fits your project
- US-based specifications: where the consultant asks for a UL 864 listed, FM approved panel and NFPA 72 requirements. For the difference between the UL and EN 54 routes see UL or EN 54.
- Mid-size buildings that grow: one loop to start, then more loops up to 2,100 points without changing the panel.
- Multi-building campuses: networking up to 32 panels over copper or fibre.
- Hospitals, schools, hotels and towers: the applications named on the product page, especially where CO detection and central monitoring are needed.
If the project specification is built on EN 54, another panel AZEIDK supplies may suit better, such as Honeywell Gent Vigilon Plus. For a general comparison see how to choose a fire alarm control panel.
Checks before ordering
- Version: IFP-2100, IFP-2100HV or display-less RFP-2100, red or black, according to the site supply voltage and whether users need a display.
- Device protocol: IDP/SK or SD, as they cannot be mixed.
- Number of loops and expanders for the actual device count, with spare capacity.
- NAC loads and required battery capacity.
- Network medium: copper or fibre.
AZEIDK handles supply, programming, testing, commissioning and maintenance through its installation service and annual maintenance contracts.
Frequently asked questions
How many points does the Farenhyt IFP-2100 support?
Up to 2,100 IDP/SK points or 2,032 SD points once SLC expanders are added.
What is the difference between the IFP-2100 and RFP-2100?
The RFP-2100 performs the same functions without a display and can be networked as long as at least one IFP-2100 is in the system.
Can IDP devices be mixed with Hochiki SD devices?
No. The datasheet states that IDP/SK and SD devices cannot be mixed in the same system.
What are Flexput circuits?
Eight output circuits that can be programmed as NACs or auxiliary power, up to 3 A each and 9 A in total.
How many panels can be networked?
Up to 32, over copper with the SK-NIC card or over fibre.
What approvals are listed for the panel?
The datasheet states compliance with UL 864 10th Edition and UL 2572 2nd Edition, a UL listing and FM approval.
Specifying a UL addressable panel? Send the device count and drawings, and the AZEIDK team will size the loops and accessories for an IFP-2100 system. Contact AZEIDK
Related guides
- Fire Alarm Systems in Khamis Mushait and Abha: Choosing a System for Shops, Schools, Hotels and Rest Houses
- Plastic Factory Fire Protection: Resin Stores, Pellets and Extrusion Lines
- How to Retrieve CCTV Footage: Search by Time, Export to USB and Hand Over
- Cat6 vs Cat6A: Speed, Distance, Shielding (UTP, F/FTP) and LSZH, and When to Choose Each