Talentum IR3 Ex d Flameproof Flame Detector 16519

Talentum IR3 Ex d flameproof flame detector by FFE (UK) with three IR sensors and a copper free aluminium IP66 housing. ATEX, IECEx, LPCB and EN 54-10 approved, detecting fires up to 25 m in oil and gas hazardous areas.
Brand
Talentum IR3 Ex d flameproof flame detector 16519 by FFE

Product Details

Product Overview

The Talentum IR3 Ex d flame detector (model 16519) by FFE, UK, is the flameproof version of the IR3, designed to protect hazardous areas where open fires may be expected. It detects almost all flames, from hydrocarbon fires with 4.3 µm emissions to invisible fires such as hydrogen, and responds to flickering infrared radiation (1 to 15 Hz) even if the lens is contaminated by oil, dust, water, vapour or ice.

Three IR sensors discriminate between flames and spurious sources of radiation, and filters plus signal processing avoid false alarms from flickering sunlight. Relay contacts or a 4-20 mA signal are selectable as standard.

ModelTalentum IR3 Ex d: EN version 16519-00, FM version 16519-20
Detection technologyThree infrared sensors (IR3), operating wavelength 1.0 to 2.7 µm
Detection rangeHigh (Class 1): 0.1 m² n-heptane fire at 25 m. Low (Class 3): 0.1 m² n-heptane at 12 m
Field of view90° minimum cone (viewing angle not to exceed ±20° to meet EN 54-10)
OutputsProgrammable relays (latching or non-latching) or 4-20 mA; relay rating 0.75 A, 48 V DC, 30 W (resistive loads only)
Supply voltage14 to 30 V DC
Current consumptionQuiescent 3, 4 or 8 mA; alarm 9, 20 or 28 mA depending on mode
HousingFlameproof (Ex d), copper free aluminium alloy, red, 158 x 149 x 137 mm, 2.3 kg
Cable entries3 x 20 mm, wiring 1.0 to 4.0 mm²
Ingress protectionIP66
Operating temperatureEN: -10 to +55 °C; FM: -20 to +60 °C; relative humidity 95% non-condensing
ApprovalsEN 54-10, LPCB, ATEX and IECEx
AccessoriesAdjustable mounting bracket 07127-00, stainless steel Ex d weather shield 07279-00, Ex d air purge 12555-00, Talentum Test Torch 1800-101

Applications

  • Refineries and onshore or offshore petrochemical sites
  • LNG and LPG production
  • Fuel loading racks and storage tanks
  • Aircraft hangars
  • Chemical plants and engine rooms
  • Coal handling, biomass, marine and military sites

FAQ

What does Ex d mean?

Ex d is the flameproof type of protection: the enclosure is built to contain an internal ignition so it does not spread to the surrounding flammable atmosphere. That is why it is used in classified hazardous areas, and this detector carries ATEX and IECEx certification.

How does it differ from the standard Talentum IR3 16589?

Same detection technology and 25 m range, but the 16519 has a red flameproof aluminium IP66 housing with three cable entries, while the 16589 has a blue zinc IP65 housing for ordinary areas.

How is it tested on site?

It has built-in automatic and manual test and can be checked with the Talentum Test Torch 1800-101. Follow the Ex d installation guide before opening the housing in a hazardous area.

Technical Documents

Product Catalogue

View the product’s full specifications and technical information in the official catalogue.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.