Wire Mesh Cable Tray from Legrand Cablofil: When to Use It for Network and Low-Current Cabling

Wire Mesh Cable Tray from Legrand Cablofil: When to Use It for Network and Low-Current Cabling

A wire mesh cable tray, often called a cable basket on site, is a cable route made of welded steel wire in an open mesh. It carries network and low-current cables above false ceilings, in telecom rooms and in data rooms. It is usually chosen because it is light and open, and cables can be added or dropped out anywhere along the run without dismantling the tray.

The structured cabling and network products AZEIDK supplies are listed under network systems.

This guide covers when a wire mesh tray suits network cabling, how to choose width and finish, and the specifications of the Legrand Cablofil CF54, available from AZEIDK alongside passive network systems and low-current systems.

Key points

  • A wire mesh tray is a light, open route for network and low-current cables that makes additions and inspection easy.
  • Cablofil CF54 is 54 mm high, 3 m long and comes in widths from 50 to 600 mm.
  • It has a 90% open structure and a safety edge that protects cables.
  • Finishes are EZ, EZ+, GC and 304L or 316L stainless steel; Legrand recommends an electrogalvanised finish for data centres.
  • Legrand states Cablofil complies with IEC 61537 and is fire-tested to DIN 4102-12.
In this article
  1. What is a wire mesh cable tray?
  2. When to choose a wire mesh tray for network cabling
  3. Legrand Cablofil CF54 specifications
  4. How to choose the tray width
  5. Choosing the finish for the location
  6. Wire mesh trays and fire performance
  7. Common installation mistakes
  8. Frequently asked questions
  9. Summary

What is a wire mesh cable tray?

Cable support systems include solid trays, perforated trays, cable ladders and wire mesh trays. Wire mesh is made of welded steel wires, so it is lighter and more open than the others. The AZEIDK product page describes it as widely used for data and low-current cable routes above false ceilings and in technical rooms.

Legrand also highlights easy visual inspection, access and maintenance of cables, even in multi-level installations.

When to choose a wire mesh tray for network cabling

  • Above false ceilings in offices, hospitals and hotels, where Cat6 or Cat6A runs feed outlets, cameras and access points.
  • In telecom and data rooms, as overhead routes over the cabinets.
  • In risers and plant rooms for runs between floors.
  • Where future additions are expected, since a new cable can enter or leave anywhere without cutting the tray.

Routes that need a full cover or high mechanical protection may be specified with another type; that decision belongs to the designer and the consultant.

Legrand Cablofil CF54 specifications

From the AZEIDK product page, based on Legrand’s official datasheet:

ItemValue
Height54 mm
Standard widths50, 100, 150, 200, 300, 450, 500, 600 mm
Length3 m
FinishesEZ, EZ+, GC, 316L stainless, 304L stainless
EdgePatented safety edge (T-joint system)
Structure90% open
Fixing systemsAutoclic, Fasclic, Faslock auto
Standards (range)IEC 61537; E30/E90 certified
Example referenceCM000101: 300 mm wide, 3 m, EZ finish

How to choose the tray width

Width depends on the number and diameter of cables on the route, plus space for future additions. Cat6A has a larger diameter than Cat6, so the same route needs more space if you choose Cat6A. In practice:

  1. Count the cables on each section of the route and take each cable’s diameter from its datasheet.
  2. Work out the required area and leave spare capacity as the project specification requires.
  3. Pick a standard width (50 to 600 mm) at the 54 mm CF54 height.
  4. List the accessories needed for bends, tees and suspension for the chosen fixing system.

For planning a structured cabling project in general see structured cabling installation for offices.

Choosing the finish for the location

  • EZ (electrogalvanised): for dry indoor areas; Legrand recommends an electrogalvanised finish for data centres.
  • 304L and 316L stainless steel: for corrosive environments, for which Legrand publishes dedicated documentation.
  • EZ+ and GC: other finishes in the range; check the datasheet for the environment each one suits.

Wire mesh trays and fire performance

Legrand states that Cablofil is fire-tested to the German standard DIN 4102-12, and the product page lists E30/E90 certification for the range. These classes cover keeping an electrical circuit working during a fire for 30 or 90 minutes, and they are the result of testing a complete system (tray, cable and fixing method), not a property of the tray alone. Where a route carries life-safety cables, the test report should be checked with the approved cable type, as the consultant requires.

For early fire detection along cable routes see linear heat detection over cable trays.

Common installation mistakes

  • Filling the tray to the top with no room for additions.
  • Running data and power cables in the same tray without the separation set by the project’s structured cabling specification.
  • Tight bends below the cable’s minimum bend radius.
  • Too few suspension points, so the tray sags between supports.
  • Not coordinating the route with electrical, HVAC and interior works on shop drawings. See ELV shop drawings.

Frequently asked questions

What is the difference between wire mesh and perforated cable trays?

Wire mesh is welded wire with an open structure, lighter and easier to drop cables out of; a perforated tray is a punched metal sheet.

How high is the Cablofil CF54?

54 mm, in 3 m lengths and standard widths from 50 to 600 mm.

Is a wire mesh tray suitable for data rooms?

Yes. The product page lists overhead cable management in data centres, and Legrand recommends an electrogalvanised finish there.

What do E30 and E90 mean for cable trays?

They are DIN 4102-12 classes for keeping a circuit working during a fire for 30 or 90 minutes, and apply to the complete tested system.

Which finish for humid or coastal areas?

The 304L or 316L stainless finishes are intended for corrosive environments; the final choice follows the datasheet and project specification.

Can fibre optic cables run in a wire mesh tray?

Yes, while respecting bend radius and any protection the project specification requires.

Summary

A wire mesh cable tray is a practical route for network and low-current cabling because it is light, open and easy to extend. Size the width from cable count and diameter with spare capacity, choose the finish for the environment, and agree fire requirements with the consultant when the route carries life-safety cables.

Preparing cable routes for a network project? Send us the drawings and cable counts per route, and the AZEIDK team will propose tray widths, finishes and accessories with datasheets. Contact AZEIDK

References: Legrand Cablofil CF54 (AZEIDK product page, based on the official datasheet); Cablofil Wiremesh Cable Baskets (Legrand)
Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.