Fire Extinguishers in Madinah: Choosing Units for Hotels, Shops and Visitor Housing, Maintenance and the Upcoming AZEIDK Showroom

Fire Extinguishers in Madinah: Choosing Units for Hotels, Shops and Visitor Housing, Maintenance and the Upcoming

Fire extinguishers in Madinah are needed by hotels, serviced apartments and visitor housing, and by shops and restaurants in the central area and commercial districts. Demand rises before the Hajj and Umrah seasons and at Salamah licence renewal. The choice starts with one question: what could burn here? Each hazard has its extinguisher type, and each area its quantity and size.

To compare extinguisher types and choose the right one for each hazard, see our fire extinguishers selection guide for facilities in Saudi Arabia.

This guide covers the right extinguisher for each type of Madinah facility, what the inspector checks, inspection and maintenance, and the status of the AZEIDK showroom in the city. AZEIDK sells extinguishers to individuals and businesses from its fire extinguishers range (Falcon Gold, FG and SFFECO) and services them with its own team under preventive and periodic maintenance contracts.

Key points

  • ABC powder for corridors and shops, CO2 for electrical rooms and equipment, wet chemical (Class K) for hotel and restaurant kitchens.
  • In hotels and visitor housing, extinguishers must be visible and signed, because guests do not know the building.
  • The SASO technical regulation requires a certificate of conformity for extinguishing equipment through SABER, so buy from a known supplier.
  • Schedule annual servicing and refilling before the season, not during it.
  • The AZEIDK Madinah showroom is listed on the contact page as “Coming Soon”, with +966 58 144 4606 as its contact number.
In this article
  1. Which extinguisher suits facilities in Madinah?
  2. Fire extinguishers in Madinah hotels and visitor housing
  3. Extinguishers and the Salamah licence
  4. How to check an extinguisher is approved
  5. Inspection, maintenance and refilling
  6. AZEIDK showroom in Madinah
  7. Placing extinguishers in a hotel building
  8. Common mistakes in hotels and visitor housing
  9. How to use an extinguisher
  10. FAQ

Which extinguisher suits facilities in Madinah?

PlaceMain hazardUsual extinguisher
Hotel and serviced apartment corridorsFurniture, furnishings, electrics6 kg powder in corridors and by stairs
Electrical, generator and server roomsElectrical equipmentCO2, no residue
Hotel, restaurant and catering kitchensCooking oil and gasFG 6 kg wet chemical next to the hood system
Shops and gift storesGoods, cartons, electricsABC powder, plus CO2 by the panel
Car parks and warehousesFuel, vehicles, storageLarger powder units and a 50 kg wheeled unit
Homes and carsKitchen, electrics, fuel1 kg powder for the car

See fire extinguisher sizes, and estimate quantities with the fire extinguisher calculator.

Fire extinguishers in Madinah hotels and visitor housing

  • Visibility: on the circulation route, by stairs and exits, with a clear sign.
  • Tamper protection: cabinets protect units in busy corridors, such as the recessed extinguisher cabinet.
  • Central kitchens: a Class K unit complements, not replaces, the hood suppression system; see kitchen fire suppression systems.
  • Before the season: check every unit, refill used ones and update tags, as inspections increase in season.

See also the hospitality sector page.

Extinguishers and the Salamah licence

  1. Units suited to the hazard, easy to reach, mounted with a sign.
  2. Gauge in the green, seal and pin in place, tag up to date.
  3. Safety equipment installation certificate: AZEIDK issues it for work it carries out.
  4. Technical report: where the licence type requires it, AZEIDK handles it through an approved engineering consultancy office.

See Civil Defense approval support and the safety equipment installation certificate.

How to check an extinguisher is approved

  • A clear label with manufacturer, extinguishing agent, capacity and fire rating.
  • The conformity certificate required by the SASO technical regulation through SABER.
  • Where the project specifies UL-listed units, see UL-listed extinguisher ratings.

Inspection, maintenance and refilling

  • Monthly: visual check by the owner; see the pressure gauge.
  • Annually: service by a qualified party.
  • After any use: immediate refill.
  • Periodically by type: hydrostatic test at the intervals set by the standard and the manufacturer.

Details in fire extinguisher maintenance and refilling.

AZEIDK showroom in Madinah

BranchAddressPhone
Madinah Showroom (Coming Soon)Coming soon+966 58 144 4606

The showroom has not opened yet and its address has not been announced. Until it opens, Madinah requests are handled on the listed number, which is the General Administration in Jeddah on Prince Majed Road (Al Safa Tower Plaza, opposite Aziz Mall). See also safety companies in Madinah and AZEIDK branches.

Placing extinguishers in a hotel building

  1. Split by hazard: corridors and rooms, electrical and generator rooms, kitchen, car parks and stores.
  2. Choose the type per area: powder for corridors, CO2 for electrics, Class K for kitchens.
  3. Set quantity and travel distance: per the design under the Saudi Fire Code (SBC 801) and Civil Defense requirements; NFPA 10 values are an international reference only.
  4. Fixed positions: by stairs and exits, in the same place on every floor.
  5. Document: number, location and service date of each unit in the safety log.

Common mistakes in hotels and visitor housing

  • Units kept in the store: an extinguisher not mounted in place counts for nothing.
  • Removed for looks: a recessed cabinet solves appearance without hiding the unit.
  • Powder only in the kitchen: oil fires need Class K and hood suppression.
  • Servicing left to the season: start early.
  • Expired tags: even a sound unit with an old tag is a remark.

How to use an extinguisher

Staff should know the PASS steps: Pull the pin after breaking the seal, Aim at the base of the fire, Squeeze the handle, Sweep side to side. Keep your back to the exit, do not fight a large or spreading fire, leave and call Civil Defense. Refill the unit after any use.

FAQ

Does AZEIDK have a showroom in Madinah?

It is listed on the contact page as “Coming Soon” and has not opened yet; requests are handled on +966 58 144 4606.

Which extinguisher suits hotel corridors?

Usually 6 kg ABC powder, placed by stairs and exits with a sign.

Which extinguisher suits a hotel kitchen?

A wet chemical (Class K) unit near the cooking line, alongside the hood suppression system.

When should extinguishers be serviced before the season?

Well before it starts, so used units are refilled and tags updated before inspections increase.

Does an extinguisher need a conformity certificate?

The SASO technical regulation requires one for extinguishing equipment through SABER.

Equipping a hotel or shop in Madinah? Send the facility type and area and we will propose types and quantities. Contact AZEIDK

Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.