Fire extinguishers in Madinah are needed by hotels, serviced apartments and visitor housing, and by shops and restaurants in the central area and commercial districts. Demand rises before the Hajj and Umrah seasons and at Salamah licence renewal. The choice starts with one question: what could burn here? Each hazard has its extinguisher type, and each area its quantity and size.
To compare extinguisher types and choose the right one for each hazard, see our fire extinguishers selection guide for facilities in Saudi Arabia.
This guide covers the right extinguisher for each type of Madinah facility, what the inspector checks, inspection and maintenance, and the status of the AZEIDK showroom in the city. AZEIDK sells extinguishers to individuals and businesses from its fire extinguishers range (Falcon Gold, FG and SFFECO) and services them with its own team under preventive and periodic maintenance contracts.
Key points
- ABC powder for corridors and shops, CO2 for electrical rooms and equipment, wet chemical (Class K) for hotel and restaurant kitchens.
- In hotels and visitor housing, extinguishers must be visible and signed, because guests do not know the building.
- The SASO technical regulation requires a certificate of conformity for extinguishing equipment through SABER, so buy from a known supplier.
- Schedule annual servicing and refilling before the season, not during it.
- The AZEIDK Madinah showroom is listed on the contact page as “Coming Soon”, with +966 58 144 4606 as its contact number.
In this article
- Which extinguisher suits facilities in Madinah?
- Fire extinguishers in Madinah hotels and visitor housing
- Extinguishers and the Salamah licence
- How to check an extinguisher is approved
- Inspection, maintenance and refilling
- AZEIDK showroom in Madinah
- Placing extinguishers in a hotel building
- Common mistakes in hotels and visitor housing
- How to use an extinguisher
- FAQ
Which extinguisher suits facilities in Madinah?
| Place | Main hazard | Usual extinguisher |
|---|---|---|
| Hotel and serviced apartment corridors | Furniture, furnishings, electrics | 6 kg powder in corridors and by stairs |
| Electrical, generator and server rooms | Electrical equipment | CO2, no residue |
| Hotel, restaurant and catering kitchens | Cooking oil and gas | FG 6 kg wet chemical next to the hood system |
| Shops and gift stores | Goods, cartons, electrics | ABC powder, plus CO2 by the panel |
| Car parks and warehouses | Fuel, vehicles, storage | Larger powder units and a 50 kg wheeled unit |
| Homes and cars | Kitchen, electrics, fuel | 1 kg powder for the car |
See fire extinguisher sizes, and estimate quantities with the fire extinguisher calculator.
Fire extinguishers in Madinah hotels and visitor housing
- Visibility: on the circulation route, by stairs and exits, with a clear sign.
- Tamper protection: cabinets protect units in busy corridors, such as the recessed extinguisher cabinet.
- Central kitchens: a Class K unit complements, not replaces, the hood suppression system; see kitchen fire suppression systems.
- Before the season: check every unit, refill used ones and update tags, as inspections increase in season.
See also the hospitality sector page.
Extinguishers and the Salamah licence
- Units suited to the hazard, easy to reach, mounted with a sign.
- Gauge in the green, seal and pin in place, tag up to date.
- Safety equipment installation certificate: AZEIDK issues it for work it carries out.
- Technical report: where the licence type requires it, AZEIDK handles it through an approved engineering consultancy office.
See Civil Defense approval support and the safety equipment installation certificate.
How to check an extinguisher is approved
- A clear label with manufacturer, extinguishing agent, capacity and fire rating.
- The conformity certificate required by the SASO technical regulation through SABER.
- Where the project specifies UL-listed units, see UL-listed extinguisher ratings.
Inspection, maintenance and refilling
- Monthly: visual check by the owner; see the pressure gauge.
- Annually: service by a qualified party.
- After any use: immediate refill.
- Periodically by type: hydrostatic test at the intervals set by the standard and the manufacturer.
Details in fire extinguisher maintenance and refilling.
AZEIDK showroom in Madinah
| Branch | Address | Phone |
|---|---|---|
| Madinah Showroom (Coming Soon) | Coming soon | +966 58 144 4606 |
The showroom has not opened yet and its address has not been announced. Until it opens, Madinah requests are handled on the listed number, which is the General Administration in Jeddah on Prince Majed Road (Al Safa Tower Plaza, opposite Aziz Mall). See also safety companies in Madinah and AZEIDK branches.
Placing extinguishers in a hotel building
- Split by hazard: corridors and rooms, electrical and generator rooms, kitchen, car parks and stores.
- Choose the type per area: powder for corridors, CO2 for electrics, Class K for kitchens.
- Set quantity and travel distance: per the design under the Saudi Fire Code (SBC 801) and Civil Defense requirements; NFPA 10 values are an international reference only.
- Fixed positions: by stairs and exits, in the same place on every floor.
- Document: number, location and service date of each unit in the safety log.
Common mistakes in hotels and visitor housing
- Units kept in the store: an extinguisher not mounted in place counts for nothing.
- Removed for looks: a recessed cabinet solves appearance without hiding the unit.
- Powder only in the kitchen: oil fires need Class K and hood suppression.
- Servicing left to the season: start early.
- Expired tags: even a sound unit with an old tag is a remark.
How to use an extinguisher
Staff should know the PASS steps: Pull the pin after breaking the seal, Aim at the base of the fire, Squeeze the handle, Sweep side to side. Keep your back to the exit, do not fight a large or spreading fire, leave and call Civil Defense. Refill the unit after any use.
FAQ
Does AZEIDK have a showroom in Madinah?
It is listed on the contact page as “Coming Soon” and has not opened yet; requests are handled on +966 58 144 4606.
Which extinguisher suits hotel corridors?
Usually 6 kg ABC powder, placed by stairs and exits with a sign.
Which extinguisher suits a hotel kitchen?
A wet chemical (Class K) unit near the cooking line, alongside the hood suppression system.
When should extinguishers be serviced before the season?
Well before it starts, so used units are refilled and tags updated before inspections increase.
Does an extinguisher need a conformity certificate?
The SASO technical regulation requires one for extinguishing equipment through SABER.
Equipping a hotel or shop in Madinah? Send the facility type and area and we will propose types and quantities. Contact AZEIDK
Related guides
- Saudi Security Surveillance Cameras Law: Facility Obligations, Recording and Retention
- Kitchen Fire Suppression Inspection and Maintenance: What Is Checked Every Six Months
- H.265 and H.265+ Video Compression in CCTV: How They Cut Recording Size and Drive Needs, and Their Limits
- Fire Protection Shop Drawings: Content and Approval
More cities: Saudi fire protection and security companies directory