In Saudi Arabia, temporary event requirements are set by the “Requirements for Event Sites and Temporary Seasonal Markets” (Ministerial Decision 4500097950/1 dated 23/7/1445 AH). They make Civil Defense approval part of the event site licence, apply the Saudi Fire Protection Code SBC 801, require fire resistant materials for kiosks, tents and sales points, and have fire requirements verified through an engineering office approved by Civil Defense.
For the steps to obtain the Salamah certificate from Civil Defense on the Salamah platform, see our guide; our page on Saudi Civil Defense requirements covers the general requirements for buildings and facilities.
This article summarises the safety clauses as published on the Ministry of Municipalities and Housing website and what an organiser needs before applying. For Civil Defense requirements and safety equipment, see AZEIDK’s Civil Defense approval support and products.
Key points
- An event site licence needs Civil Defense approval, traffic approval and a detailed site plan from an approved engineering office.
- Fire protection follows SBC 801 and is verified through an engineering office approved by the General Directorate of Civil Defense.
- Kiosks, tents and sales points use fire resistant materials and comply with SBC 801 Chapter 31.
- A temporary event permit is limited to 180 days and cannot be renewed; temporary stages to 30 days.
- Government bodies holding events on their premises must also meet fire prevention requirements and obtain Civil Defense approval.
In this article
- What do temporary event requirements cover?
- Documents for an event site licence
- Fire clauses in temporary event requirements
- What is left to the safety plan
- Power, CCTV and infrastructure
- Permit durations
- Events held by government bodies
- Common mistakes on event sites and seasonal markets
- Checklist before applying
- FAQ
What do temporary event requirements cover?
The document covers event sites and temporary seasonal markets: spaces set up for a limited period with kiosks, tents, sales points, stages and seating, whether by an investor on leased land or by a government body on its own premises. It regulates the site licence, permits for sales points and vehicles inside it, and infrastructure, safety and operation.
Large crowds, closely spaced light structures, temporary wiring and food areas make fire a real risk, which is why the licence is tied to Civil Defense from the start.
Documents for an event site licence
- A commercial registration covering events.
- A detailed site plan prepared by an approved engineering office.
- Civil Defense approval.
- Traffic approval.
- Title deed, lease or investment contract.
- Municipal approval of site suitability.
- The event request form on Balady.
A sales point or vehicle permit inside the event needs a commercial registration, a lease from the event licence holder and a valid vehicle licence where relevant. Operating without a licence is prohibited.
Fire clauses in temporary event requirements
| Item | What the document says |
|---|---|
| Technical reference | Saudi Fire Protection Code SBC 801 |
| Verification of fire requirements | Through an engineering office approved by the General Directorate of Civil Defense |
| Kiosks, tents and sales points | Fire resistant materials; comply with SBC 801 Chapter 31 |
| Theatres and stages | SBC 201 Section 410; temporary stages up to 30 days in materials the code allows |
| Space under stages | Only for plumbing and electrical services for stage equipment |
| Smoking | A designated area away from shops and rest areas; no smoking in corridors |
| Maintenance | Electrical installations, wiring and safety systems maintained to a schedule with records |
SBC 801 Chapter 31 is the reference the document gives for tents and temporary structures; the engineering office applies its technical detail in the safety plan. Their role is covered in Civil Defense approved engineering offices.
What is left to the safety plan
The document does not set extinguisher numbers, alarm type or exit counts. These follow from SBC 801 in the safety plan, based on site area, visitor numbers, kiosk layout and cooking areas, and are submitted to Civil Defense. In practice the organiser needs:
- Suitable extinguishers in each zone, especially food areas, generators and temporary electrical boards.
- Clear escape routes and signs, see fire evacuation plan board.
- An alarm method suited to an open or covered site, as decided by the designer.
- Cooking areas separated from closely spaced tents and sales points.
AZEIDK supplies extinguishers and safety equipment from its branches and supports Civil Defense requirements for event sites.
Power, CCTV and infrastructure
Event sites need basic infrastructure such as power and lighting, with electrical installations, wiring and safety systems maintained to a schedule and records kept. Lighting such as lasers may not be aimed at drivers on nearby roads, and security cameras must meet Ministry of Interior approved specifications.
Permit durations
- Temporary event permit: up to 180 days, not renewable.
- Temporary theatre or stage operating permit: up to 30 days, not renewable.
With such short permits, safety preparations must be complete before opening.
Events held by government bodies
Government bodies holding events on their own premises must also meet the fire prevention section and obtain Civil Defense approval, so an event inside an existing building still needs a safety review, especially when stages or kiosks are added or attendance exceeds normal use. Permanent event halls are covered in wedding and event hall safety requirements, and exhibitions in exhibition centre fire safety.
Common mistakes on event sites and seasonal markets
- Buying tents or covers without evidence of fire resistance.
- Running temporary cables across walkways or under tents without protection or a maintenance plan.
- Placing generators or cooking cylinders next to closely spaced kiosks and seating.
- Adding kiosks after the plan is approved, narrowing walkways and escape routes.
- Leaving the smoking area in corridors or next to sales points.
- Relying on an earlier event permit, although temporary event permits cannot be renewed.
Most of these are avoided by approving the safety plan before buying materials and placing kiosks.
Checklist before applying
- Have an approved engineering office prepare the site plan and SBC 801 safety plan.
- Confirm kiosk, tent and sales point materials are fire resistant, with supplier evidence.
- Place smoking, cooking and generator areas away from corridors and assembly points.
- Install extinguishers, evacuation signs and alarm as per the plan.
- Prepare a maintenance plan for electrical installations and safety systems for the whole event.
- Apply on Balady with Civil Defense and traffic approvals.
FAQ
Does a temporary event need Civil Defense approval?
Yes. It is one of the documents for the event site licence, including for government bodies holding events on their premises.
Which code applies to event tents?
The document refers to SBC 801 Chapter 31 and requires fire resistant materials for kiosks, tents and sales points.
How long is a temporary event permit?
Up to 180 days, not renewable; a temporary stage permit up to 30 days.
Who verifies fire requirements on an event site?
An engineering office approved by the General Directorate of Civil Defense.
Does the document set the number of extinguishers?
No. That is set in the safety plan under SBC 801.
Is a municipal licence enough without Civil Defense?
No. Civil Defense approval is one of the documents required for the event site licence.
Can a temporary event permit be renewed?
No. It is limited to 180 days and cannot be renewed.
Is smoking allowed on the site?
Only in a designated area away from shops and rest areas; not in corridors.
Organising an event or seasonal market? Send us the site area, number of kiosks and cooking areas, and AZEIDK will supply the safety equipment needed and follow up Civil Defense requirements. Contact AZEIDK
Related guides
- American Fire Control FM-200 System: AFC-227 vs AFC-P227, Cylinder Sizes and Pressures
- Isolating Fire Detectors During Hot Work and Maintenance: Preventing False Alarms Without Leaving the Building Unprotected
- Room Integrity Testing for Gas Suppression Systems
- CCTV Recorder Error Messages on Hikvision and Dahua: HDD, Network, Login and Video Exceptions