Talentum UV/IR2 Ex d Flameproof Flame Detector 16521

Talentum UV/IR2 Ex d flameproof flame detector by FFE (UK) with one UV and two IR sensors in an aluminium IP66 housing. Solar blind and immune to arc welding, with ATEX, LPCB, VdS and EN 54-10 approvals for hazardous areas.
Brand
Talentum UV/IR2 Ex d flameproof flame detector 16521 by FFE

Product Details

Product Overview

The Talentum UV/IR2 Ex d flame detector (model 16521) by FFE, UK, is a flameproof ultraviolet and dual infrared detector designed to protect hazardous areas where open fires may be expected. It detects almost all flames, from hydrocarbon fires to invisible fires such as hydrogen.

An alarm is signalled only when the UV and IR sensors detect radiation at the same time, so false alarms from flickering sunlight, arc welding and lightning are eliminated. It suits indoor and outdoor areas and offers selectable relay contacts or a 4-20 mA signal.

ModelTalentum UV/IR2 Ex d: EN version 16521-00
Detection technologyUV sensor (185 to 260 nm) and two IR sensors (1.0 to 2.7 µm)
Detection rangeHigh (Class 1): 0.1 m² n-heptane fire at 25 m. Low (Class 3): 0.1 m² n-heptane at 12 m
Field of view90° minimum cone (viewing angle not to exceed ±20° to meet EN 54-10)
OutputsProgrammable relays (normally open or normally closed, latching or non-latching) or 4-20 mA; relay current 0.75 A max.
Supply voltage14 to 30 V DC
Current consumptionQuiescent 3, 4 or 8 mA; alarm 9, 20 or 28 mA depending on mode
HousingFlameproof (Ex d), copper free aluminium alloy, red, 154 x 150 x 145 mm, 2.3 kg
Cable entries3 x M20, wiring 1.0 to 4.0 mm²
Ingress protectionIP66
Operating temperature-10 to +55 °C; relative humidity 95% non-condensing
ApprovalsEN 54-10, VdS, LPCB and ATEX
AccessoriesAdjustable mounting bracket 07127-00, stainless steel weather shield 07279-00, Ex d air purge 12555-00, Talentum Test Torch 1800-101

Applications

  • Refineries and onshore or offshore petrochemical sites
  • Aircraft hangars
  • Fuel loading racks and storage tanks
  • LNG and LPG production
  • Chemical plants and engine rooms
  • Marine industry and military applications

FAQ

Why choose a UV/IR2 Ex d detector for oil and gas sites?

It combines a flameproof enclosure with UV/IR detection that needs both signals at once, so it is far less affected by sunlight, arc welding and lightning on open sites.

Does it carry IECEx?

The datasheet for this model lists EN 54-10, VdS, LPCB and ATEX. Check current approvals with the manufacturer before specifying it on a project.