SIP Intercom for Offices and Buildings: Fanvil i64 or Grandstream GDS3710? Camera, Cards and PBX

SIP Intercom for Offices and Buildings: Fanvil i64 or Grandstream GDS3710? Camera, Cards and PBX

SIP intercom for offices and buildings: Fanvil i64 or Grandstream GDS3710? When a building has an IP PBX, the door station can call office phones and reception screens directly instead of running a separate intercom system. The Fanvil i64 and the Grandstream GDS3710 are door stations of this kind, and AZEIDK supplies both in Saudi Arabia. This article compares them using the figures on the product pages: camera, cards, durability and power, and when to choose each.

Both units belong to the low current systems AZEIDK delivers, and they work with the building’s network and communication systems.

Key points

  • Both units use SIP, with a 2 MP camera, a keypad and PoE 802.3af Class 3 or 12 V power.
  • The GDS3710 has a 180 degree horizontal view and IK09 impact protection; the i64 has a 120 degree view and IK07.
  • The i64 reads 125 kHz and 13.56 MHz cards and stores 10,000 cards; the GDS3710 reads 125 kHz (EM4100) cards.
  • The GDS3710 has two relay outputs and two alarm inputs; the i64 has a built-in relay, 3 inputs and 2 outputs.
  • For answering inside the flat or office there is the Fanvil i504 indoor station with a 7-inch touchscreen.
In this article
  1. How does a SIP intercom differ from a conventional intercom?
  2. Fanvil i64 vs Grandstream GDS3710
  3. Cards: which one suits your current staff cards?
  4. When to choose the Fanvil i64
  5. When to choose the Grandstream GDS3710
  6. What goes in the BOQ?
  7. FAQ
  8. Summary

How does a SIP intercom differ from a conventional intercom?

A conventional or single-brand intercom links the door station to indoor monitors from the same maker, as in intercom systems for villas and apartment buildings. A SIP door station registers on the PBX like any IP phone, so the door can ring the reception phone, a guard’s handset or a SIP indoor screen. That makes it a good fit for offices, clinics and buildings with a PBX such as Grandstream UCM or Yeastar P-Series.

Fanvil i64 vs Grandstream GDS3710

ItemFanvil i64Grandstream GDS3710
Camera2 MP, 1/2.9 in sensor2 MP (1920 x 1080), 1/2.7 in sensor
Field of view120 degrees horizontal, 60 vertical180 degrees horizontal, 150 vertical
IlluminationNot stated on the pageWhite LEDs for day and night, 0.5 lux minimum
Keypad12 numeric and 4 function keys, backlit12 keys and a capacitive doorbell button, each lit
Card reader125 kHz and 13.56 MHz, 10,000 cards125 kHz EM4100
Inputs and outputs3 inputs, 2 outputs, built-in relay2 alarm inputs, 2 relay outputs rated 30 V DC at 2 A
ProtectionIP66 and IK07IP66 and IK09
PowerPoE 802.3af Class 3 or 12 V DC, 1 APoE 802.3af Class 3 or 12 V DC, 1 A
Operating temperature-40 to +70 C-30 to +60 C

Source: the Fanvil i64 and Grandstream GDS3710 pages on the AZEIDK website, taken from the official product pages and datasheets.

Cards: which one suits your current staff cards?

EM cards work at 125 kHz and Mifare cards at 13.56 MHz, as explained in EM or Mifare cards. The i64 page lists both frequencies; the GDS3710 page lists 125 kHz in EM4100 format. If your staff use Mifare cards, confirm the card type in the datasheet before choosing, and test a real card on the unit.

When to choose the Fanvil i64

  • You need 13.56 MHz cards, or 10,000 cards stored on the unit itself.
  • The entrance faces summer heat, since its stated operating range reaches +70 C.
  • You want a single-brand system with the Fanvil i504 indoor station (7-inch touchscreen, with an i504W Wi-Fi version).

When to choose the Grandstream GDS3710

  • You need a wide view from the door; 180 degrees covers the whole entrance.
  • The site is exposed to tampering, since IK09 is higher than IK07.
  • The PBX is a Grandstream UCM and the client wants one brand, or the video should also go to an NVR, as the product page states.
  • You need to drive two locks, or a door and a gate, using the two relay outputs.

What goes in the BOQ?

  • Door station model, plus the indoor screen or phones that will take the call.
  • Lock type (magnetic or strike) and how it behaves in a power cut; see fail safe vs fail secure.
  • A PoE switch port per unit, or a 12 V supply where PoE is not available.
  • The number of SIP extensions needed on the PBX, and the card type.

FAQ

Does a SIP door station work without a PBX?

A SIP unit is designed to register on an IP PBX or SIP server, and the GDS3710 page mentions sending calls and video to IP phones, video phones and smartphones. Operation without a PBX varies by model, so check the datasheet.

Which is better for a villa, the i64 or the GDS3710?

For a villa without a PBX, a conventional intercom is usually simpler. If the villa or office runs on an IP PBX, the GDS3710 gives a wider view and higher impact protection, and the i64 gives wider card support.

Are both units suitable for outdoor mounting?

Yes, both are IP66 according to the product pages. The difference is impact rating: IK09 on the GDS3710 and IK07 on the i64.

Does AZEIDK offer other SIP options?

Yes, including the ZYCOO network intercom for SIP paging and intercom.

Summary

The Fanvil i64 is stronger on cards and temperature range; the Grandstream GDS3710 is stronger on field of view, impact resistance and outputs. Send AZEIDK the number of entrances, your PBX type and your current cards, and we will recommend the right unit with installation and programming through a quote request.

Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.