An addressable sounder takes its power and commands from the fire alarm loop itself, so it does not need a separate sounder circuit from the panel as a conventional system does. AZEIDK supplies the Context Plus range in Saudi Arabia: compact wall and ceiling sounders, 103 dB hi-output sounders, sounder beacons that combine sound and light, and IP65 open-area sounders. This guide sorts the models by location and sound level, from the product pages and catalogue.

The devices are part of AZEIDK fire alarm systems. For the general picture of bells, sounders and strobes see fire alarm bells, sounders and strobes.

Key points

  • An addressable sounder runs from the loop; most Context Plus models include a short-circuit isolator and group addressing to operate several devices together.
  • For offices and corridors: the compact CON450A/CX/SR at 91 dB(A) at one metre.
  • For large or noisy spaces: the CON430A/CX/DR wall sounder at 103 dB(A) with 7 volume levels.
  • Where a visual alarm is needed: CON451A/CX/SR and CON433A/CX/DR with EN54-23 beacons.
  • For warehouses, car parks and exposed areas: 55000-001 and 55000-005IMC at 100 dB(A) with IP65 protection.
In this article
  1. Addressable vs conventional sounders
  2. Context Plus models from the product pages
  3. Where each type goes
  4. Loop loading: why sounder current matters
  5. EN54-23 beacon coverage codes
  6. Frequently asked questions

Addressable vs conventional sounders

In a conventional system the panel provides separate sounder circuits, each with its own cable and end-of-line resistor, and every sounder on the circuit operates together. An addressable sounder sits on the same loop cable as the detectors and call points and has an address the panel knows, so the panel monitors it and operates it according to the cause and effect matrix. Group addressing lets a whole group operate at once. To drive conventional sounders from an addressable panel there is the 55000-852IMC sounder control unit.

Context Plus models from the product pages

ModelTypeSound at 1 mProduct page notes
CON450A/CX/SRCompact wall/ceiling sounder91 dB(A)Onboard isolator, third-party certified to EN54-3 and EN54-17, IP21C, 5 mA alarm current
CON451A/CX/SRCompact sounder beacon91 dB(A)EN54-3, EN54-17 and EN54-23; C-3-8 on ceiling, W-3-2.1 on wall; 14 mA alarm current
CON458A/CX/SRBeacon onlyNo soundEN54-17 and EN54-23; 10 mA alarm current
CON430A/CX/DRHi-output wall sounder103 dB(A)7 volume levels, up to 15 tone pairs, LPCB certified to EN54-3 and EN54-17, 5 mA alarm current; IP65 version available
CON433A/CX/DRHi-output wall beacon sounder103 dB(A)LPCB certified to EN54-3, EN54-17 and EN54-23; W-2.4-8.2; IP65 version available
55000-001Open-area sounder100 dB(A) at 90°Loop powered, IP65, isolating base supplied, EN54-3:2001
55000-005IMCOpen-area sounder beacon100 dB(A)Red lens, built-in isolator, IP65, EN 54-3 and LPCB approved, typically about 15 per loop subject to loading

Approvals differ by model: some pages name the LPCB, others state third-party certification without naming the body. Submittals should quote only what is written for each model.

Where each type goes

  • Offices, hotels, corridors and classrooms: the compact CON450A, or the CON451A sounder beacon where a visual alarm is also needed, for example for people with hearing impairment.
  • Factories, plant rooms and large halls: the 103 dB(A) CON430A or CON433A, set to one of 7 volume levels so the alarm stands above ambient noise. See industrial fire alarm systems.
  • Warehouses, car parks and exposed areas: 55000-001 or 55000-005IMC with IP65, or the IP65 versions of the wall sounders. For outdoor devices generally see IP65 outdoor fire alarm sounders.
  • Hotel and hospital rooms: a sounder in the detector base may suit better; see smoke detector bases.
  • Where a spoken evacuation message is needed: choose a voice sounder instead of a tone.

Loop loading: why sounder current matters

Every addressable sounder draws loop current in alarm, and the models differ widely: 5 mA for the CON450A or CON430A and 14 mA for the CON451A or CON433A sounder beacons, per the product pages. That is why the 55000-005IMC page gives a typical figure of about 15 units per loop and requires a loop-loading calculation. Many visual devices on one loop can exceed what the loop can supply, so the load is spread over more loops or handled another way in the design. For device and isolator distribution see addressable loop design and loop isolators.

EN54-23 beacon coverage codes

Devices with a beacon carry a light distribution code such as C-3-8 for ceiling mounting and W-3-2.1 or W-2.4-8.2 for wall mounting. The letter shows the mounting type and the numbers describe the size of the covered space in metres. See EN 54-23 visual alarm devices for how to read them.

Frequently asked questions

What is an addressable sounder?

An audible alarm device on the addressable loop that takes power and commands from it and has an address the panel monitors.

How loud are Context Plus addressable sounders?

By model: 91 dB(A) for the compact CON450A, 103 dB(A) for the CON430A wall sounder and 100 dB(A) for the open-area units.

Does an addressable sounder need its own cable?

No, it sits on the loop cable, but the loop load must be calculated because each device draws current in alarm.

How many sounder beacons per loop?

The 55000-005IMC page gives about 15 per loop as a typical value; the final number comes from the design’s loading calculation.

Is there an addressable sounder for outdoor use?

Yes, such as the 55000-001 and 55000-005IMC with IP65, and IP65 versions of the CON430A and CON433A.

What does the built-in isolator do?

It isolates the affected section when a cable short occurs, so the rest of the loop keeps working.

Specifying sounders for an addressable project? Send the drawing and the type of each space, and the AZEIDK team will propose the model and sound level and calculate the loop load. Contact AZEIDK

References: Context Plus product pages on the AZEIDK site: CON450A, CON451A and CON458A, CON430A, CON433A, 55000-001 and 55000-005IMC, and the Context Plus addressable sounders and beacons catalogue.