Fire Suppression System Suppliers in Jeddah: Server, Electrical and Archive Rooms, Clean Agent and Aerosol

Fire Suppression System Suppliers in Jeddah: Server, Electrical and Archive Rooms, Clean Agent and Aerosol

Fire suppression system suppliers in Jeddah are usually sought by a facility manager fitting out a server or electrical room, a contractor who needs a gas system for a telecom room or archive, or a warehouse owner protecting switchboards. Water does not suit these spaces, so they are protected with special suppression: clean agents such as HFC-227ea (FM-200) and FK-5-1-12, condensed aerosol, or carbon dioxide for unoccupied spaces.

For how clean agent systems are designed, kept safe and maintained, see our FM-200 fire suppression system guide.

This guide explains which system suits each type of Jeddah facility, what to ask the supplier, and how the system passes the consultant and Civil Defense. AZEIDK supplies, installs and tests these systems under special fire suppression systems, and its head office is in Jeddah. Kitchen hood systems are a separate solution under kitchen fire suppression systems.

Key Takeaways

  • Choose by hazard and room: clean agent for occupied rooms and sensitive equipment, aerosol for panels and small closed rooms, CO2 for unoccupied spaces only.
  • Agent quantity is calculated from room volume and design concentration, not estimated from floor area.
  • The room must be tight, and this is tested before handover; this is often neglected in older buildings.
  • Available from AZEIDK: Context Plus 227 with its cylinders and EP203 panel, AFC FM-200, FirePro aerosol, and SFFECO 1230 and CO2 systems.
  • In Jeddah: the General Administration, four showrooms and the main warehouse in Al Khumra.
In this article
  1. Which Jeddah facilities need special suppression?
  2. Which systems does AZEIDK supply in Jeddah?
  3. What to ask fire suppression system suppliers in Jeddah before you sign
  4. Older Jeddah rooms: the integrity problem
  5. How the system passes the consultant and Civil Defense in Jeddah
  6. AZEIDK branches in Jeddah
  7. Maintenance after handover
  8. Common mistakes on Jeddah projects
  9. Frequently Asked Questions
  10. Summary

Which Jeddah facilities need special suppression?

SpaceWhere you find it in JeddahUsual system
Server and telecom roomsOffices, banks, hospitals and telecom operators across north and central JeddahClean agent (HFC-227ea or FK-5-1-12)
Archive and records roomsGovernment bodies, courts, banks and companiesClean agent per the value of the contents and the consultant’s design
Electrical rooms and switchboardsTowers, hotels and mallsClean agent for the room, or aerosol for panels and small rooms
Enclosed generator and transformer roomsFactories and warehouses in the industrial cities and Al KhumraPer design; CO2 may be used if the room is unoccupied
Control panels and cabinetsFactories, service stations and warehousesAerosol or a local system inside the panel

Archives have their own guide, archive room fire protection, and agents are compared in clean agent suppression comparison.

Which systems does AZEIDK supply in Jeddah?

SystemAgentProduct page
Context Plus 227HFC-227eaContext Plus 227 agent, cylinders 35 to 1200 lb, EP203 control panel
AFC FM-200HFC-227eaAmerican Fire Control FM-200 system
SFFECO 1230FK-5-1-12SFFECO 1230 system
FireProCondensed aerosolFirePro system
SFFECO CO2Carbon dioxideSFFECO CO2 system, unoccupied spaces only

The brand name alone does not settle it. The agent and components must be listed or approved as the specification requires, and the design must come from the approved calculation software of that system. Brands are covered in special fire suppression brands in the Saudi market.

What to ask fire suppression system suppliers in Jeddah before you sign

  • Quantity calculations: room volume, design concentration and number of cylinders or generators from the system’s calculation software.
  • Datasheets and listings: for agent, cylinder, valve, nozzles and control panel.
  • Sequence of operation: two detectors before release, a time delay, hold and abort buttons, HVAC shutdown and warning signs at the door.
  • Room integrity test: who does it, when, and what happens if the room fails.
  • Maintenance: cylinder weighing or liquid level reading, detector and panel checks, and who recharges after a discharge.

AZEIDK selects the system with the client under technical selection of systems and equipment and prepares calculations under engineering design and calculations.

Older Jeddah rooms: the integrity problem

Many server and electrical rooms in Jeddah were never designed for a gas system. They have open AC openings, false ceilings that connect to the corridor, unsealed cable openings and doors with no closer. The agent leaks out before the required hold time, and the integrity test fails. The fix starts at the survey: list and seal the openings, fit a door closer, and decide which HVAC units stop on release. Jeddah’s coastal humidity is another reason to review room sealing and air conditioning, as frequent door opening brings humid air onto the equipment. AZEIDK starts this with a technical site inspection and assessment.

How the system passes the consultant and Civil Defense in Jeddah

  1. Design approval: calculations, drawing and sequence of operation from the engineering office or design contractor.
  2. Submittal: technical documents for the components before delivery.
  3. Installation: cylinders, piping, nozzles, detectors and panel, with the interface to the building fire alarm.
  4. Testing: sequence of operation without discharge, the room integrity test, and recorded results. An example is in FM-200 testing procedure.
  5. Salamah licence: AZEIDK handles the technical report through an approved engineering consultancy office and issues the safety equipment installation certificate for systems it installed. See Civil Defense approval support.

AZEIDK branches in Jeddah

Jeddah branch details as listed on the contact page:

BranchAddressPhone
General Administration, JeddahPrince Majed Road, Al Safa Tower Plaza, opposite Aziz Mall+966 58 144 4606 | +966 56 937 4142
Jeddah Showroom, Al Baladiyah Street (Al Aziziyah)Al Baladiyah Street, Al Aziziyah District+966 54 929 4109
Jeddah Showroom, Al Baladiyah Street (next to Raya)Al Baladiyah Street, next to Raya+966 54 361 7373
Jeddah Showroom, Al Sabeen StreetPrince Majed Road, before the Hira and Al Sabeen intersection+966 54 360 7373
Jeddah Showroom, Khalid Bin Al Waleed Street (Security Systems)Khalid Bin Al Waleed Street+966 54 905 3818
Main Warehouse, Jeddah (Al Khumra)Al Wizarat District, Al Khumra–

Project enquiries for gas systems start at the General Administration with the room drawing and dimensions. Complementary portable units, such as portable FM-200 extinguishers, are available at the showrooms.

Maintenance after handover

A gas system that is not inspected may discharge without a fire or fail to discharge when needed. Periodic inspection covers detectors, panel, cylinder weight or level, nozzles, and any room change that affects integrity, under annual maintenance contracts.

Common mistakes on Jeddah projects

  • Reusing one room’s calculation for another room of a different size.
  • Adding racks or opening an AC duct after the test without reassessing integrity.
  • Installing CO2 in a room staff enter regularly.
  • Relying on a portable extinguisher for a main server room.
  • Not training the room owner on the hold and abort buttons.

Frequently Asked Questions

Who supplies fire suppression systems in Jeddah?

AZEIDK is one of the suppliers in Jeddah, where its head office is, and supplies Context Plus 227, AFC FM-200, FirePro and SFFECO systems with installation and testing.

FM-200 or aerosol for a server room?

It depends on room size, occupancy and the consultant’s requirements. See FM200 generator or aerosol generator.

Can CO2 be used in a room people enter?

CO2 at extinguishing concentration is dangerous to people, so it is used in unoccupied spaces with entry precautions, as the design defines.

Does the room need an integrity test?

Yes for total flooding systems, because the agent must hold the required concentration long enough.

Does AZEIDK serve Makkah, Taif and Yanbu from Jeddah?

AZEIDK has showrooms in Makkah and Taif. There is no branch in Yanbu; projects there are coordinated with the General Administration in Jeddah.

What does a gas suppression system cost?

It depends on room volume, agent, number of cylinders and sealing works, and is not priced before the calculations.

Summary

In Jeddah, define the hazard and the room first, then the agent. Ask the supplier for calculations, documents and the sequence of operation, fix room integrity before the test, and make periodic inspection part of the contract.

Fitting out a server or electrical room in Jeddah? Send the room dimensions and equipment type and we will propose a system with calculations and datasheets. Contact the AZEIDK team

Share this article