Jack Pump Diesel Fire Pump Skid to NFPA 20: Components, Options and What to Check Before Ordering

Jack Pump Diesel Fire Pump Skid to NFPA 20: Components, Options and What to Check Before Ordering

A diesel fire pump skid means the fire pump and the diesel engine are mounted and aligned on one base plate and tested at the factory before shipping. This guide explains the Jack Pump packaged diesel skid built to NFPA 20: what it includes, the engine, controller and accessory options, and what to check before ordering and installing it, based on the official Jack Pump catalogue.

The skid is available from AZEIDK as part of our fire fighting systems. Details and the datasheet are on the Jack Pump diesel driven fire pump skid page, and the other pumps are on the Jack Pump page.

Key points

  • A listed and approved centrifugal fire pump with a listed and approved diesel engine, on one coated hot rolled mild steel base plate.
  • The skid is built around an end suction or a split case pump, as the project requires.
  • Diesel engines in the catalogue: Black Stallion 15 to 390 HP or Kirloskar 62 to 330 HP, both UL Listed and FM Approved.
  • Skid packages are tested and inspected at the factory before release.
In this article
  1. What is a packaged diesel fire pump skid?
  2. Skid components and options
  3. When to choose a packaged diesel skid
  4. What to check before ordering
  5. Installation and commissioning
  6. Frequently asked questions

What is a packaged diesel fire pump skid?

In a traditional installation the pump and engine are supplied separately, the base is built and the shaft alignment is set on site. A skid arrives assembled: pump and engine directly coupled and aligned on a single base plate with a fabricated C-channel frame and anchor bolt holes. The Jack Pump catalogue notes the compact footprint suits existing pump rooms for retrofit.

For the code components of a diesel fire pump, see diesel fire pump components per NFPA 20.

Skid components and options

ItemWhat the catalogue states
PumpEnd suction pump 50 to 1000 US GPM up to 230 psi, or a split case pump as the project requires
Diesel engineBlack Stallion 15 to 390 HP at 1400 to 3000 RPM, or Kirloskar 62 to 330 HP at 1760 to 3000 RPM
ControllerTornatech, UL Listed and FM Approved, or the customer’s choice of Firetrol or Hubbell
Air relief valveVal-Matic, 1/2 to 2 inch, up to 300 psi
Flow meterGerand, FM Approved, 2-1/2 to 8 inch, up to 300 psi
BaseOne piece coated hot rolled mild steel with a heavy C-channel frame

The catalogue also states that listed Jack Pump pumps can be coupled with any other listed diesel engine on request, and that its controllers are factory assembled and tested to UL 218. For Tornatech options, see GPx and GPD controllers.

When to choose a packaged diesel skid

  • When you need a main or standby pump that does not depend on the power supply, as explained in electric vs diesel fire pumps.
  • When replacing an old pump in a tight room, since the skid is compact and arrives aligned.
  • When the owner or consultant wants less alignment work on site, because coupling and testing are done at the factory.

To choose the pump type itself, see Jack Pump fire pump types.

What to check before ordering

Duty point

The flow and pressure from the hydraulic calculations set the pump type and engine power. See fire pump sizing per NFPA 20.

Certificates

Ask for UL and FM certificates for the pump, engine and controller, the pump performance curve and the factory test report for the skid in the submittal.

Pump room

Skid footprint with service clearances, fuel tank, ventilation, exhaust and suction and discharge piping. See the fire pump room guide.

Civil Defense requirements

Design and testing follow the approved drawings and the building’s Civil Defense requirements, which AZEIDK follows up through its Civil Defense approval support.

Installation and commissioning

On arrival the skid is anchored to its concrete foundation, then suction, discharge, fuel, exhaust and controller connections are made, alignment is checked again after piping, and the running and flow tests follow. The steps are in fire pump installation step by step. AZEIDK carries out installation, testing and handover and annual maintenance.

Frequently asked questions

How does a diesel skid differ from buying the pump and engine separately?

On a skid the pump and engine arrive coupled and aligned on one base and tested at the factory, so there is less alignment work on site.

Which diesel engines are offered with the Jack Pump skid?

Per the catalogue: Black Stallion 15 to 390 HP or Kirloskar 62 to 330 HP, both listed and approved.

Can the skid use a split case pump?

Yes. The catalogue shows a diesel skid with an end suction pump and another with a split case pump; the type follows the required flow.

Which controller is used?

Tornatech, listed and approved, or the customer’s choice of Firetrol or Hubbell.

Is the skid tested before delivery?

Yes. The catalogue states skid packages are tested and inspected before release, and a site test follows installation.

Is there an electric motor skid?

The Jack Pump catalogue also shows a motor driven skid with WEG motors. Ask AZEIDK what is available for your project.

Need a diesel fire pump skid for a new building or to replace an existing pump? Send AZEIDK the duty point and drawings, and we will propose the pump, engine and controller. Read also: Clarke diesel engines and diesel fire pump engine maintenance. Request a quote from AZEIDK

Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.