An emergency escape stair is the route people use to leave a building in a fire, when lifts are off limits. What makes it work is not the stair itself but its protection: fire-rated walls, a self-closing fire door, lighting that stays on when the power fails, and a discharge that leads outside. This guide covers the protected stair only; exits in general are covered in emergency exit requirements.
AZEIDK supplies and installs fire-rated doors and emergency exit solutions, emergency lighting and exit signs, and checks layouts before submission through its drawings and specifications review. Building the stair itself is the structural contractor’s work.
Key points
- The binding reference in Saudi Arabia is the Saudi Building Code: SBC 201 Chapter 10 (Means of Egress), with fire protection requirements in SBC 801.
- Stair width is calculated from the number of people served and never falls below the code minimum.
- A protected stair is enclosed by fire-rated walls and doors, and the required rating rises with the number of storeys it connects.
- The stair must end at an exit discharge or a public way, not an enclosed lobby.
- Emergency lighting, exit signs and floor level signs are part of the stair, not optional extras.
Escape stair versus an ordinary stair
An ordinary stair serves daily movement and may be open to the floor. An escape stair is a protected exit: an enclosure separated from the rest of the building by fire-rated walls and floors, with fire doors, no storage and no services that do not belong there. The aim is a stair that stays usable long enough even with a fire on the next floor. External stairs follow the same principles: a clear route, enough width and a safe end at ground level.
Emergency escape stair requirements: width, steps and landings
SBC 201 Chapter 10 sets the stair dimensions in figures, and the designer must use the adopted edition. The principles behind them are constant:
- Width: a fixed minimum, increased as the number of people on the floors served grows.
- Headroom: clear height over the full stair and landing width, with no ducts, cable trays or panels dropping into it.
- Steps: riser height and tread depth within a minimum and maximum, and uniform within a flight.
- Landings: at the top and bottom of every flight, with a depth tied to the stair width and a limit on the rise of one flight.
- Handrails: on both sides.
Most drawing comments are not about the figures but about the site: a stair correct on paper, then narrowed by a hose cabinet, an electrical panel or a door swinging onto the landing. Review architectural, fire and electrical drawings together.
Fire protection of the stair enclosure
- Wall rating: the enclosure has fire-rated walls and ceiling, and SBC 201 sets the rating by the number of storeys connected; taller buildings need longer ratings.
- Doors: self-closing fire doors rated to suit the wall. See fire door rating by location and the emergency exit door guide.
- Penetrations: restricted to listed items such as fire protection systems and services for the stair itself; any later opening needs a fire-rated seal.
- Termination: at an exit discharge or a public way.
Keeping smoke out: stair pressurisation
In high-rise buildings the code calls for smokeproof stair enclosures, usually achieved with a positive pressure system that keeps smoke out when doors open. See smoke control and stair pressurisation and smoke extraction and emergency ventilation systems.
Lighting and signs inside the stair
A dark stair slows evacuation more than anything else, so every flight and landing needs emergency lighting that switches on automatically on power failure, with clear exit signs at the doors. Duration and light levels are in the emergency and exit lighting guide.
In multi-storey buildings each floor landing carries a sign showing the floor level, the direction to the exit and whether the stair reaches the roof, so occupants know where they are and Civil Defense crews know which floor they are climbing to.
Findings that keep coming up
- Stair doors wedged open, so they fail in a fire.
- Boxes or furniture stored on landings or under the stair.
- The ground-floor exit door locked with a key-operated lock.
- Dead emergency light batteries.
- Unsealed service openings in the stair wall after maintenance work.
These usually surface during a Civil Defense visit before occupancy or renewal, and are easy to fix if checked beforehand.
Frequently asked questions
How wide must an emergency stair be?
SBC 201 Chapter 10 sets a minimum, and the width increases with the number of people served. The designer calculates it from the occupant load.
Is one stair enough?
It depends on occupancy, occupant load and travel distance. Most multi-storey buildings need at least two exits per floor, set by the designer under the code.
Are escape stair walls fire rated?
Yes. A protected stair has fire-rated walls and self-closing fire doors, and the required rating rises with the number of storeys.
Can a hose cabinet sit inside the stair?
Some designs place hose or standpipe outlets at stair landings, provided they do not reduce the required width. The approved drawings decide.
When does a stair need pressurisation?
When the code requires a smokeproof enclosure, mostly in high-rise buildings. The system is designed and tested before handover.
Can lifts be used instead of the stair?
Normally no. Standard lifts are not used in a fire; the escape stair remains the main route down.
Drawings going for approval? AZEIDK reviews fire doors, emergency lighting and exit signs along the escape routes before submission. Contact AZEIDK
Related guides
- Access Controller Wiring: Reader, Maglock, Exit Button, Door Contact and Fire Alarm Lock Release
- Salamah Certificate for Factories: Fire Alarm, Firefighting and Document Requirements by Industrial Activity
- LPCB Certification: What It Means for Fire Protection Equipment
- Pre-Action Sprinkler System: Single and Double Interlock, and When to Use It for Server Rooms and Archives