KHIND emergency lights and exit signs come in two families that AZEIDK supplies in Saudi Arabia: the UL listed EM07 range, and the portable, wall-mounted and exit sign models made in Malaysia. This guide brings together the KHIND models listed on our product pages, compares battery, run time and protection rating, and explains when each model makes sense.
AZEIDK works on emergency exits and escape lighting as part of its life safety scope. Every product of the brand is on the KHIND page and in the emergency and exit lighting category.
Key points
- The EM07 models are UL listed and run for 3 hours on most models, or 180 minutes on the EM0730 exit sign.
- EM0701, EM0702 and EM0703 work in maintained or non-maintained mode, are rated IP65 and use LiFePO4 batteries.
- The EM0730 exit sign carries an Arabic and English EXIT legend with arrows, and the EM0703 can carry the same legend.
- The Malaysian models such as EM 2007 and KS 2023 are built for long run times, up to 7.5 hours, and their pages do not state a UL listing.
The UL listed EM07 family: models and differences
If the project specification calls for UL listed emergency luminaires, this is the family to start with. The data below comes from our product pages and the KHIND catalogue:
- Eclipse Edge EM0701: 1.6 W LED exit light, 3.2 V 1.5 Ah LiFePO4 battery, 3 hours, IP65. Accessories include a recessed box, recessed base, EM0701A double-sided diffuser and a wire guard.
- TrustLite EM0702: 4 W multifunctional emergency light that becomes an exit sign with the supplied pictogram stickers, 3 hours, IP65.
- SafeGlow EM0703: 4 W emergency bulkhead that can carry an Arabic and English EXIT legend, 3 hours, IP65.
- X-Guard EM0720: twin-lamp light with 2 x 2 W LEDs, 3.6 V 1500 mAh Ni-Cd battery, 3 hours or more. It is rated IP20, so it is for indoor dry areas only.
- EvacBright EM0721: twin-head light with 2 x 3 W LEDs and 650 lm, covering about 80 m². It runs on 120/277 V, 60 Hz, with 90 minutes or 3 hours of backup depending on the version.
- Xst Streem EM0730: LED exit sign with a green Arabic and English EXIT legend and direction arrows, 600 mAh Ni-Cd battery, 180 minutes.
The EM0720 and EM0721 housings are flame-retardant thermoplastic rated UL 94V-0, with a test switch, a charge indicator and overcharge and over-discharge protection.
Portable, wall-mounted and exit sign models made in Malaysia
These models all run on 220-240 V, are rated IP65 and have a battery indicator. Their main advantage is run time, and some can be lifted off the wall and carried as a hand light during evacuation or maintenance.
| Model | Type | Battery | Run time | Max. output |
|---|---|---|---|---|
| EM 0811 NM | Wall light | LiFePO4 1800 mAh | 2 hours | 250 lm |
| EM 2004 GT | Portable, twin tube | Li-ion 2.2 Ah | 6 h low, 3 h high | 250 lm |
| EM 2007 LED | Portable | Li-ion 2200 mAh | 7.5 h low, 5 h high | 400 lm |
| EM 2020 TS | Portable, triple tube | Li-ion 2.2 Ah | 6 h low, 3 h high | 350 lm |
| EM 3120 LED | Portable | Li-ion 2.2 Ah | 7 h low, 4 h high | 500 lm |
| EM 2030 | Twin head | Sealed lead acid 6 V 4.5 Ah | 4 h, both heads | 800 lm |
| EM 3030 | Twin head | Sealed lead acid 6 V 4.5 Ah | 6 h one head, 4 h both | 1100 lm, both heads |
| KS 2023 | Exit sign | Li-ion 2200 mAh | 6 hours | over 30 lm |
| KS 2024 | Exit sign, running man and arrow pixel display | Li-ion 2200 mAh | 5 hours | 50 lm |
On the KS 2023 and KS 2024 exit signs the arrow direction can be set to suit the mounting position.
How to choose the right KHIND model
Start from the specification, not the model
The number and spacing of luminaires and the required duration come from the approved emergency lighting design and the consultant’s specification. If the specification asks for UL listed fittings, choose from the EM07 family; if long run time or a hand-carried light is needed, the Malaysian models fit better.
Match voltage and protection rating to the location
Check the supply voltage in the datasheet before ordering: most models run on 220-240 V, while the EvacBright EM0721 runs on 120/277 V. In pump rooms, car parks and areas exposed to dust or water spray choose an IP65 model, and keep the X-Guard EM0720 for dry indoor areas.
Bilingual exit signs
Where the authority or consultant asks for Arabic and English exit signs, the direct choice is the Xst Streem EM0730, or the SafeGlow EM0703 with the bilingual EXIT legend.
Plan periodic testing from day one
The test switch and charge indicator on most models make monthly and annual checks easier. See our guide to emergency lighting and exit sign inspection.
Datasheets, catalogue and quotation
The KHIND catalogue and the UL listed range catalogue can be downloaded from each product page. For a technical and commercial offer, send drawings, a BOQ or the specification, and state the model, mounting type (surface or recessed) and operating mode (maintained or non-maintained). AZEIDK handles model selection, submittals, supply, installation and testing before handover.
Frequently asked questions
What is the difference between KHIND EM07 lights and the other models?
The EM07 family is UL listed and runs for 3 hours on most models. The Malaysian models such as EM 2007 and EM 3030 run longer, up to 7.5 hours in low mode, and their pages do not state a UL listing.
Does KHIND make an Arabic exit sign?
Yes. The Xst Streem EM0730 carries an Arabic and English EXIT legend with arrows, and the SafeGlow EM0703 can carry the same legend.
Which KHIND light runs the longest?
The EM 2007 LED runs up to 7.5 hours in low mode and 5 hours in high mode, according to its product page.
Are KHIND lights suitable for damp areas?
Most models are rated IP65 against dust and water jets. The X-Guard EM0720 is rated IP20, so it is for indoor use only.
Are KHIND products available from AZEIDK?
Yes. KHIND products are available from AZEIDK in Saudi Arabia, with technical selection, supply, installation and testing.
Need emergency lights or exit signs for a building in Saudi Arabia? Send AZEIDK your drawings or BOQ and our team will select the models and run times. Read also: emergency and exit lighting guide and what drives emergency lighting cost. Request a quote from AZEIDK







