An IP horn speaker such as the Hikvision DS-QAZ1307G1T-E connects to the network over a single cable that carries both audio and power (PoE), and plays scheduled, live or emergency messages across yards, car parks and perimeter fences. It is rated at 7 W with a maximum sound pressure of 121 dB SPL, and carries IP67 and IK10 ratings, so it suits sites exposed to sun and dust. This article explains when to use it, how to link it to cameras and an IP PBX, and where it stops short of a fire alarm voice evacuation system.
Key takeaways
- The DS-QAZ1307G1T-E is an outdoor network horn speaker: 7 W rated power, 121 dB SPL maximum, 110 dB sensitivity at 1 m / 1 W.
- It is powered by IEEE 802.3at PoE with a 16.4 W maximum draw, so it needs a PoE+ switch port.
- It supports SIP, ONVIF, ISAPI, ISUP and RTP, has two microphones for two-way audio, and 4 GB of storage with 1 GB for audio files.
- IP67 and IK10 rated, operating from -40 °C to 60 °C.
- It is a security paging and warning device. It does not replace a listed voice evacuation system within the fire alarm.
In this article
- What is an IP horn speaker?
- Hikvision DS-QAZ1307G1T-E specifications
- Where are outdoor horn speakers used in Saudi Arabia?
- How do you link the speaker to cameras and the PBX?
- PoE power: what to check on the switch
- Can a horn speaker replace a voice evacuation system?
- Outdoor installation tips
- Frequently asked questions
- Conclusion
What is an IP horn speaker?
A horn speaker is a directional loudspeaker with a flared horn that throws sound further forward than a ceiling speaker. In conventional PA systems it is fed from a central amplifier on a 100 V line. A network horn speaker has its own amplifier and processor built in, and plugs straight into a network switch with a Cat6 cable, just like an IP camera, taking power and audio from the same cable.
That changes the design approach on large sites. Instead of running a long audio cable from the amplifier room to a fence or yard, you use a network point that often already exists for a nearby camera. This is why these speakers appear in security and surveillance projects, not only in PA systems.
Hikvision DS-QAZ1307G1T-E specifications
The values below come from the AZEIDK product page, which is based on Hikvision’s official datasheet:
| Item | Value | What it means for you |
|---|---|---|
| Rated power | 7 W | Suited to warning and guidance messages in open areas, not high-level music |
| Max. sound pressure | 121 dB SPL | Audible over vehicle and equipment noise in yards |
| Sensitivity (1 m, 1 W) | 110 dB | Used to calculate the sound level at the listening position |
| Frequency response | 300 Hz to 13 kHz | Tuned for speech clarity |
| Directivity | 70° horizontal, 100° vertical | Sets the mounting direction and spacing along a fence |
| Microphones | 2, electret | Two-way audio with the security room |
| Network | 1 x RJ45, 10/100 Mbps | One network point per speaker |
| Protocols | SIP, ONVIF, ISAPI, ISUP, RTP | Integration with IP PBX and video systems |
| Local storage | 4 GB eMMC, 1 GB for audio | Pre-recorded messages that play without a central PC |
| Power | PoE IEEE 802.3at, 16.4 W max. | PoE+ port required; counts in the switch PoE budget |
| Protection | IP67, IK10, metal housing | Withstands dust, rain and impact |
| Operating temperature | -40 °C to 60 °C | Handles hot-region summers with sensible mounting |
Where are outdoor horn speakers used in Saudi Arabia?
Car parks and open yards
Mall and hospital car parks sometimes need to guide drivers or announce a gate closure. A horn speaker on a lighting pole or building wall does this from one network point.
Fences around warehouses and factories
The most common use is live deterrence. When a smart camera detects someone approaching the fence at night, the guard sees the scene and speaks through the speaker, or the speaker plays a recorded message automatically. A live voice deters more than a generic siren because the person knows they are being watched.
Entry gates and loading yards
In loading yards a supervisor may need to call a truck driver or alert workers without leaving the control room. Two-way audio lets the driver answer through the built-in microphones.
Residential compounds
Useful for general announcements in gardens and outdoor courts and for alerts at gates. For the full compound security design see safety systems for compounds, villas and residential buildings.
How do you link the speaker to cameras and the PBX?
Protocol support decides how flexible the speaker is on a project:
- SIP: the speaker registers as an extension on an IP PBX, so a guard can dial it from a desk phone and talk live.
- ONVIF and ISAPI: interfaces used by video systems. Within a Hikvision system a camera event can trigger an audio message; the project engineer confirms the method for the recorder and software in use.
- ISUP: Hikvision’s protocol for remote management platforms.
- RTP: transport for live audio over the network.
The internal storage is useful for fixed messages such as “This is a restricted area” that play on a schedule or on an event, without relying on a central PC to stream the file.
PoE power: what to check on the switch
The speaker draws up to 16.4 W and is IEEE 802.3at compliant. So:
- Confirm the switch port supports 802.3at (PoE+). A port limited to 802.3af is not enough for this load.
- Add the speakers to the cameras and Wi-Fi access points on the same switch and compare the total with the PoE budget in the datasheet. The method is in our article on PoE switch power budget for CCTV.
- Keep copper Ethernet runs within 100 m between switch and speaker. For longer fence runs use a field switch or fibre.
- Put the switch on a UPS if the speaker is part of the night security plan.
Switches available from AZEIDK include the Hikvision DS-3E1309P-EI; port type and budget are checked against the device count on each site.
Can a horn speaker replace a voice evacuation system?
No. Voice evacuation in buildings is part of the fire alarm system, designed to the Saudi Fire Protection Code SBC 801 and the standards the consultant adopts, with speakers and amplifiers listed for that purpose, fault monitoring and secondary power. The product page does not list EN 54-24 or UL approval for this speaker, so it is for security paging and warnings only. For the difference see voice evacuation alarm systems.
Outdoor installation tips
- Aim the horn at the target area, not at neighbouring homes, and use the 70° horizontal angle to space speakers along the fence.
- Mount it out of easy reach and use weatherproof junction boxes for the cable joint.
- Test the sound by day and by night; road and equipment noise differ between the two.
- Record each speaker’s extension number and IP address in the handover documents.
- Include the speakers in the low current and CCTV maintenance contract, which is separate from the fire and life safety maintenance contract.
Frequently asked questions
How many horn speakers do I need for a 200 m fence?
It depends on site noise, the listening distance and mounting height. The engineer works it out from sensitivity and coverage angle after a site survey; there is no fixed number.
Does the Hikvision DS-QAZ1307G1T-E work without a PBX?
Yes. Stored messages can play on a schedule or on camera events. A PBX adds the ability to call the speaker from any internal phone over SIP.
Do I need a separate amplifier?
No. The amplifier is built in and powered by PoE. That is the main difference from traditional horn speakers on a 100 V line from a central amplifier.
Can it handle the Saudi summer?
The datasheet operating range goes up to 60 °C, with IP67 against dust and water. Avoid mounting it on exposed metal surfaces that trap heat.
Is it suitable for music or mosque sound systems?
Its 300 Hz to 13 kHz response is aimed at speech clarity. Mosque sound and music need speakers and systems designed for that purpose.
Is the speaker covered by the fire systems maintenance contract?
No. It belongs to the security and low current system and is maintained under the CCTV and low current contract, separate from the fire, safety and alarm contract.
Conclusion
An outdoor IP horn speaker gives your surveillance system a voice: live warnings at the fence, guidance in car parks and paging in loading yards, from one network cable. Selection starts with noise and distance, then a check of the PoE+ port and switch budget, then integration with cameras or the PBX. Do not confuse it with listed voice evacuation speakers in the fire alarm system.
Want to add audio warnings to your cameras? Send your site layout and camera positions to the AZEIDK team to define speaker quantities, positions and switch and PBX integration, using Hikvision products from our public address and audio systems range. Talk to the AZEIDK team
Related guides
- Hikvision DS-3WAP623E-SI Outdoor Access Point: Wi-Fi 6 for Yards, Car Parks and Compounds
- Fire Safety Systems in Saudi Buildings: Alarm, Suppression, Emergency Lighting, Doors and What Civil Defense Requires
- When Is a Fire Alarm System Mandatory? SBC 801 Requirements by Occupancy
- How Does a Fire Sprinkler System Work? Smoke, Broken Heads and Hanging Loads