FirePro FP-1200 Box Type Condensed Aerosol Fire Suppression Generator

FirePro FP-1200 box type condensed aerosol generator with 1200 g of FPC compound and electrical activation, KIWA certified to EN 15276-1 and ISO 15779, for electrical and equipment rooms.
Brand
مولد إطفاء بالأيروسول المكثف FirePro FP-1200

Product Details

Product Overview

The FirePro FP-1200 is a box type condensed aerosol fire suppression generator holding 1200 g of FPC compound. It is electrically activated from the releasing control panel and is used in aerosol fire suppression systems for electrical rooms, equipment rooms and other enclosed spaces. It is KIWA certified to BRL-K21045, EN 15276-1 and ISO 15779 and is suitable for class A, B, C and F fires.

ModelFP-1200 (epoxy-coated mild steel housing), FP-1200S (stainless steel 304 housing)
TypeBox type condensed aerosol fire suppression generator
FPC compound mass1200 g
ActivationElectrical
Electrical resistance1.60 to 3.60 Ω
All-fire current≥ 0.8 A / 10 ms
Minimum pulse voltage1.5 Vdc
Monitoring current4 mA recommended (max. 10 mA)
Gross weight10900 g ±5% (excluding bracket)
Dimensions219 x 342 x 174 mm (excluding bracket)
Discharge time15 to 20 seconds
Stream length3.5 m
Safety distance L31.5 m (distance at which the temperature does not exceed 75 °C)
Operating temperature-40 °C to +75 °C
HumidityUp to 95%
Fire classesA, B, C, F (as per EN2)
CertificationKIWA certified to BRL-K21045, EN 15276-1, ISO 15779
Agent environmental dataODP zero, GWP negligible

Applications

  • Electrical switch rooms, transformer rooms and distribution panels
  • Server, telecom and control rooms
  • Generator, pump and mechanical equipment rooms
  • Stores and enclosed spaces that need a suppression system without piping

Frequently asked questions

What is the difference between FP-1200 and FP-1200S?

The technical data is the same; the difference is the housing: FP-1200 has an epoxy-coated mild steel housing and FP-1200S a stainless steel 304 housing.

Is FP-1200 available with thermal activation?

Yes. The official datasheet lists FP-1200T and FP-1200TS with electrical and thermal activation. The FP-1200 itself is electrically activated only.

How many generators does a room need?

The quantity comes from the engineering design, based on the room volume, the hazard and the applicable standard. The AZEIDK technical team prepares the design and calculations for each project.

Specifications are taken from the official FirePro datasheet (TDS-4000.20, version 2026-01). You can download the datasheet from AZEIDK. Supplied by AZEIDK in Saudi Arabia with design, installation and technical support.

Technical Documents