Addressable fire alarm systems
Bosch AVENAR all-in-one 4000 Addressable Sounder-Beacon (FNX-425U)
Brand
Bosch
View Product
→
AZEIDK Solutions
Integrated Engineering Solutions for Safer Facilities
Fire protection, low current systems, and electromechanical solutions.
Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
The Context Plus Remote LED Indicator is designed for use in fire alarm systems to indicate the activation of hidden or out-of-sight fire detectors.
The unit incorporates a high-intensity, wide-angle red LED that is clearly visible from the front of the plate when active.
The front label includes a white write-on panel, allowing installers to add personalised text such as the detector location or equipment reference.
The unit can be fitted to 16mm-deep surface or flush-mount back boxes.
The catalogue states that the detector manufacturer’s instructions should always be checked before connecting the BF318 to a smoke or heat detector.
For maximum brightness and visibility, detector outputs that are already current limited should be connected directly to the 0V and LED Only terminals.
Key Features:
• High-intensity red LED.
• Wide viewing angle.
• Suitable for hidden or out-of-sight detectors.
• White write-on panel for customised location text.
• Suitable for surface or flush mounting.
• Fits 16mm-deep back boxes.
• Compatible with suitable remote-indicator outputs from fire detectors.
Technical Specifications:
• Product number: BF318.
• Current using the 0V and LED Only terminals depends on the detector type used.
• Current using the 0V and +30V Max terminals:
10mA at 30V DC maximum.
1.3mA at 6V DC minimum.
View the product’s full specifications and technical information in the official catalogue.
Explore more products available in this category.