Honeywell fire alarm systems are not one system. They come as several product families under different names, each with its own approval route and design philosophy. AZEIDK supplies three of them in Saudi Arabia: Honeywell Gent with Vigilon Plus panels, Notifier with the NFS2-640, and Honeywell Farenhyt with the IFP-2100. This guide compares them from each panel’s official datasheet, so you know which family matches your specification before requesting a quotation.
All three are part of AZEIDK fire alarm systems. For the wider market picture see fire alarm brands in Saudi Arabia.
Key points
- Gent Vigilon Plus: the EN 54 route, 2 to 6 loops with up to 200 devices per loop, networking up to 200 panels.
- Notifier NFS2-640: the UL route, one loop expandable to two with 318 devices per loop, plus voice evacuation, firefighter telephone and large networks.
- Farenhyt IFP-2100: also UL, one loop expandable to 2,100 points, eight Flexput circuits, a built-in communicator and networking up to 32 panels.
- Selection starts from the specification: EN 54 usually leads to Gent; UL and NFPA lead to Notifier or Farenhyt depending on size and required functions.
Why three Honeywell families?
Each family grew up serving a different market and standard set. Gent is a British family built on EN 54, while Notifier and Farenhyt are built on US UL standards and NFPA 72. So the useful question is not “is Honeywell good?” but “which Honeywell family matches the approved specification?”. For the difference between the two routes see UL or EN 54.
Datasheet comparison
| Item | Gent Vigilon Plus | Notifier NFS2-640 | Farenhyt IFP-2100 |
|---|---|---|---|
| Stated approvals | EN54 Parts 2 and 4 | UL 864 10th edition, UL listed, FM approved | UL 864 10th Edition and UL 2572, UL listed, FM approved |
| Loops | 2, 4 or 6 | One, expandable to two with LEM-320 | One built-in, expandable with 6815 or 5815XL |
| Devices per loop | Up to 200 | 159 detectors + 159 modules (318) | 159 detectors + 159 modules (IDP/SK) or 127 devices (SD) |
| Panel limit | EN54-2 restricts 4 and 6 loop panels to 512 sensors and call points | 636 devices | 2,100 points (IDP/SK) |
| Networking | Up to 200 panels, copper or fibre (4 and 6 loop) | Up to 200 nodes high-speed, or 103 standard | Up to 32 panels, copper or fibre |
| Integrated standby | 24 h for 2 and 4 loop, 72 h for 6 loop | Per project calculation | Cabinet holds two 18 Ah batteries |
| Notable extras | S-Quad and S-Cubed devices with speech, sounder and EN54-23 VAD | Single or multichannel voice, firefighter telephone | Eight Flexput circuits, IP and phone-line communicator |
Honeywell Gent Vigilon Plus
Vigilon Plus comes in three sizes: Compact Plus with two loops, Vigilon Plus with four, and a six-loop panel. Each loop takes up to 200 sensors, interfaces, call points, sounders and visual alarms. The datasheet notes that EN54-2 limits the 4 and 6 loop panels to a maximum of 512 sensors and call points, a point often missed in capacity planning. The display is 8 lines by 40 characters and networking reaches 200 panels. Design details are in our Honeywell Gent Vigilon Plus guide.
Notifier NFS2-640
The NFS2-640 is a modular ONYX Series panel that starts small and grows with peripheral equipment. Each loop supports 159 detectors and 159 modules, expandable to two loops for 636 devices. Its options include single or multichannel voice evacuation, firefighter telephone and graphic annunciators, with large networks of up to 200 nodes, which is why it appears in hospitals, malls, towers and airports. See Notifier NFS2-640 in Saudi Arabia.
Honeywell Farenhyt IFP-2100
The IFP-2100 combines a built-in loop expandable to 2,100 points, eight Flexput circuits programmable as NACs or auxiliary power, and an IP and phone-line communicator in one cabinet. It networks up to 32 panels, with the display-less RFP-2100 as a companion, and works with the family’s addressable CO detector. See Farenhyt IFP-2100 and addressable carbon monoxide detectors.
Which family fits your project?
- EN 54 or BS 5839 specifications: Gent Vigilon Plus is the natural choice of the three, with speech and EN54-23 visual devices. For BS 5839 categories see BS 5839-1 categories vs NFPA 72.
- UL and NFPA specifications with voice and wide networks: Notifier NFS2-640.
- UL specifications for a mid-size building that will grow: Farenhyt IFP-2100 with up to 2,100 points and built-in output circuits.
- Extending an existing system: stay with the installed family, because each family’s devices work only with its own panels. See fire alarm spare parts compatibility.
Common mistakes when ordering “a Honeywell system”
- Writing “Honeywell” in the BOQ without naming the family, which brings offers for systems that do not match the specification.
- Mixing devices from two families on one panel; each datasheet lists its compatible devices only.
- Planning Vigilon capacity at 200 devices per loop without the 512 sensor and call point limit the datasheet states for 4 and 6 loop panels.
- Assuming a UL approval on one family applies to another; read each panel’s own datasheet.
AZEIDK supplies, programs, tests, commissions and maintains all three families through its technical supply service and annual maintenance contracts.
Frequently asked questions
Are Notifier, Gent and Farenhyt different companies?
They are product families under Honeywell, each with its own panels, devices and standards, so they should not be treated as one system.
Which Honeywell panel is approved to EN 54?
Of these three, the Gent Vigilon Plus datasheet states EN54 Parts 2 and 4, while the NFS2-640 and IFP-2100 datasheets state UL standards.
How many devices per loop on the Notifier NFS2-640?
159 detectors and 159 modules, 318 per loop and 636 per panel once expanded to two loops.
How many panels can a Gent Vigilon network hold?
Up to 200 panels over copper or fibre, on the 4 and 6 loop panels per the datasheet.
Can Notifier detectors go on a Gent panel?
No. Each panel works only with the devices in its compatibility list.
Which family suits voice evacuation?
The Notifier NFS2-640 offers single or multichannel voice and firefighter telephone, while Gent offers S-Cubed speech devices on the loop. The approved specification decides.
Does your specification name Honeywell? Send the specification and BOQ, and the AZEIDK team will identify the matching family and prepare the submittal. Contact AZEIDK
Related guides
- Fire Pump Controller Maintenance: Weekly Checks, Annual Testing, Pressure Switch and Transfer Switch
- Fire Hydrants and Landing Valves: Selection and Maintenance
- Fire Alarm Symbols on Drawings: Legend, Layout Plan and Riser for Civil Defense and Shop Drawings
- CCTV Design Tool Guide: Lens and Coverage Calculators, Drawing and Simulation Software, and What to Ask Your Designer