Hikvision Parking Barriers DS-TMG: DS-TMG320-B vs DS-TMG423-B (Fence Boom) vs DS-TMG520 and Where Each Fits

Hikvision Parking Barriers DS-TMG: DS-TMG320-B vs DS-TMG423-B (Fence Boom) vs DS-TMG520 and Where Each Fits

Choosing a Hikvision parking barrier from the DS-TMG range comes down to three models AZEIDK GROUP supplies in Saudi Arabia: the compact 24 VDC DS-TMG320-B with body indicator lights, the DS-TMG423-B with a fence boom and IK09 rating, and the DS-TMG520 with a straight boom up to 6 m and opening from 0.9 s. The real differences are boom type and length, opening time, cycle life, supply voltage and the inputs available for inductive loops and plate recognition.

This guide compares the three using figures from AZEIDK’s product pages and Hikvision’s official datasheets, then covers where each fits, power and foundation preparation, and what to check during maintenance.

Key takeaways

  • DS-TMG520 is the fastest to open: octagonal straight boom up to 6 m, 0.9 s opening on the 3 m H version, 5,000,000 cycles.
  • Per AZEIDK’s product page, DS-TMG423-B uses a fence boom in 3, 4 or 5 m, or 2.5+2.5 m, rated IP54 and IK09, with 5,000,000 cycles.
  • DS-TMG320-B is compact, with a 24 VDC motor, switchable 110/220 VAC supply, Bluetooth app setup and 2,500,000 cycles.
  • All three use a brushless DC motor and IP54 protection; the DS-TMG320-B and DS-TMG520 datasheets state a 100% duty cycle.
  • DS-TMG320-B and DS-TMG520 have a dedicated loop/IR/radar input and an RS-485 port for parking management integration.
In this article
  1. How do the Hikvision parking barrier models differ?
  2. DS-TMG320-B: compact barrier for residential and office entrances
  3. DS-TMG423-B: fence boom where the barrier must be clearly visible
  4. DS-TMG520: fast barrier for wide lanes and heavy traffic
  5. Which Hikvision barrier suits your site?
  6. Inductive loop and LPR camera integration
  7. Installation notes: power and concrete base
  8. Maintenance points specific to these models
  9. Hikvision parking barriers from AZEIDK GROUP
  10. Frequently asked questions
  11. Summary

How do the Hikvision parking barrier models differ?

DS-TMG320-B and DS-TMG520 figures come from Hikvision’s official datasheets; DS-TMG423-B figures are as stated on AZEIDK’s product page.

ItemDS-TMG320-BDS-TMG423-BDS-TMG520
Boom typeOctagonal straight, telescopic, folding or light poleFence boomOctagonal straight, anti-collision round or telescopic
Boom lengthFrom 1.5+1.5 m up to 3.6–6 m telescopic, by version3 m, 4 m, 5 m or 2.5+2.5 mRound 1–4 m, octagonal 1–6 m, telescopic 4–6 m
Rising time3 s (3 m) to 6.5 s (3.6–6 m telescopic)3 s (4 m boom)0.9 s (H, 3 m), 1.5 s (M, 4 m), 4 s (L, 6 m)
Cycles2,500,0005,000,0005,000,000
Voltage24 VDC motor, 110/220 VAC supply220 VAC220 VAC ±15%
Consumption120 WMax. 176 W300 W (max. 4 A)
ProtectionIP54IP54, IK09IP54
Operating temperature-30 to 70 °C-30 to 60 °C-30 to 70 °C
Body indicatorsRed-green lightGreen arrow, red stop lightNone (output for an external traffic light)
Boom installation height880 mm885 mm880 mm
Body weight37.79 kgNot stated on product page59.3 ± 5 kg

DS-TMG320-B: compact barrier for residential and office entrances

The DS-TMG320-B has a compact 1.5 mm SGCC housing that Hikvision describes as suited to side installation. A 24 VDC brushless motor runs from a 110 or 220 VAC mains supply selected by switch. Setup is done from a phone app over Bluetooth, so most settings change without opening the cabinet.

It comes in four versions by boom length and direction: ML/B and MR/B for booms up to 4 m, and LL/B and LR/B for longer booms such as the 3.6–6 m telescopic and 2.5+2.5 m folding poles. The final L or R sets left or right boom direction, so confirm the lane layout before ordering.

  • Boom closing delay adjustable from 10 to 600 s (30 s default).
  • 433.5 MHz remote, up to 64 remotes paired.
  • Raising the boom on power failure is optional and needs an emergency lifting module ordered separately.

It fits villa and residential building entrances, offices and staff car parks with moderate traffic. For busy commercial entrances, its 2.5 million cycle rating is half that of the other two models.

DS-TMG423-B: fence boom where the barrier must be clearly visible

A fence boom typically carries vertical bars or a grille below the arm, so the barrier reads as a solid block rather than a thin line. Per AZEIDK’s product page, the DS-TMG423-B takes 3, 4 or 5 m booms, or a 2.5+2.5 m boom, with 3 s rising and falling on a 4 m boom.

The page states that the /B version adds body indicators: a green arrow to pass and a red stop light. It is rated for 5,000,000 cycles with a brushless DC motor and runs on 220 VAC at a maximum of 176 W. Its IK09 rating indicates higher impact resistance on the housing, which the other two datasheets do not state.

It suits factory, warehouse and compound gates and perimeter checkpoints where pedestrians and cyclists need to see the barrier clearly. One point to note: its upper operating temperature is 60 °C against 70 °C for the other two, so shading the cabinet at exposed entrances is sensible in a Saudi summer. The product page does not list loop or RS-485 inputs, so confirm them on the official datasheet before design.

DS-TMG520: fast barrier for wide lanes and heavy traffic

The DS-TMG520 is heavier than the DS-TMG320-B, with a thicker 2 mm steel housing with UV-resistant powder coating, a variable-frequency brushless DC motor and 5,000,000 cycles at 100% duty cycle. It comes in three versions by boom length:

  • DS-TMG520-H (3 m): 0.9 s rising by default, adjustable to 0.9, 1.2 or 2 s. Suits mall and hospital car parks where queues build quickly.
  • DS-TMG520-M (4 m): 1.5 s rising by default, or 2 s with the telescopic boom.
  • DS-TMG520-L (5 and 6 m): 4 s rising by default, for wide lanes and truck gates. Booms of 5 m and above come with a spindle rod.

Rising and falling speeds are set separately: fast up to clear the queue, slower down to reduce the risk of the boom striking a vehicle or person. Boom direction can be switched on site. There are no body indicators, but there is an output for an external traffic light on its own supply up to 220 VAC.

Which Hikvision barrier suits your site?

SiteBest fitWhy
Villa or residential buildingDS-TMG320-BCompact housing, app setup, limited daily traffic
Office staff car parkDS-TMG320-B or DS-TMG520-MDepends on lane width and peak-hour volume
Mall, hospital or hotel entranceDS-TMG520-H0.9 s rising and 5 million cycles
Factory, warehouse or compound gateDS-TMG423-BVisible fence boom, IK09, arrow indicator
Truck lane or wide gateDS-TMG520-LBoom up to 6 m with spindle rod

Start from the measured lane width, then select boom length, then the matching version. For a European comparison with booms up to 8 m, see our BFT parking barriers guide.

Inductive loop and LPR camera integration

The DS-TMG320-B and DS-TMG520 datasheets list a similar I/O set: rising-limit and falling-limit signals, open, close and stop inputs, an RS-485 port, and one input for an inductive loop detector, IR sensor or radar that stops the boom falling onto a vehicle. The DS-TMG520 network port is marked reserved, so do not design around it yet.

In practice the barrier is controlled three ways:

  • Relay: an ANPR/LPR camera or card reader sends a dry-contact open command to the Open input.
  • RS-485 or software command: from the parking management system. The DS-TMG520 datasheet mentions automatic control via a parking management system, and AZEIDK’s product page notes it can be linked to plate recognition or card access.
  • Remote and push buttons: for the guard, or manual operation if plate reading fails.

The loop here is a safety device: it holds the boom up while a vehicle is over it. For Hikvision’s all-in-one entry/exit unit and what affects read accuracy, see the DS-TMC407-EH plate recognition guide.

Installation notes: power and concrete base

  • Supply: DS-TMG520 needs 220 VAC ±15% at up to 4 A; DS-TMG423-B runs on 220 VAC; DS-TMG320-B accepts 110 or 220 VAC via a selector switch set before start-up.
  • Power failure: DS-TMG320-B needs the separately ordered emergency lifting module; on DS-TMG520 lifting on power loss is not supported by default and the boom can be operated manually with a tool. Agree with the owner what the entrance should do during an outage and whether backup power is needed.
  • Base: fix the cabinet on a level concrete plinth sized to the installation manual, with conduits for power, control and loop cables laid before the pour.
  • Loop: cut the slot under the boom path and keep it as far as practical from rebar and power cables to reduce false detections.
  • Weight and anchoring: the DS-TMG520 body weighs about 59 kg and the DS-TMG320-B about 38 kg; prepare anchors as the installation manual specifies.

AZEIDK carries out this work under its installation service, with the barrier tied into entrance cameras as part of security and surveillance systems.

Maintenance points specific to these models

General barrier faults (boom, loop, photocell, motor) are covered in our parking barrier maintenance guide. Points specific to these Hikvision models:

  • Test the loop or radar input regularly with a vehicle on the loop and the boom up; the boom must not fall.
  • Recheck the closing delay after any reset and confirm it is at the intended value; the defaults are 30 s on DS-TMG320-B and 10 s on DS-TMG520.
  • When replacing a boom, use a pole type matched to that version (ML or LL on DS-TMG320-B; H, M or L on DS-TMG520). A longer boom on a version built for a shorter one changes the balance.
  • Check the cabinet door seal to keep IP54 protection, especially after dust seasons.

Hikvision parking barriers from AZEIDK GROUP

AZEIDK GROUP supplies all three models in Saudi Arabia, with installation and integration into parking management and plate recognition, as part of its low current systems. For the full parking system picture before choosing a barrier, see parking management and automatic barrier systems.

Frequently asked questions

Which is the fastest Hikvision parking barrier?

The DS-TMG520-H with a 3 m boom, rising in 0.9 s by default per the datasheet, adjustable to 1.2 or 2 s.

What is the longest boom available from AZEIDK in these models?

6 m on the DS-TMG520-L (octagonal or telescopic), and 3.6–6 m telescopic on the DS-TMG320-B LL/B and LR/B versions.

What does the fence boom on the DS-TMG423-B do?

It fills part of the gap under the arm, making the barrier more visible to pedestrians and cyclists at factory, warehouse and compound gates.

Can a Hikvision barrier open on licence plate recognition?

Yes, when an LPR camera is connected to the Open (relay) input or through the parking management system over RS-485, with a remote or card kept as backup.

What happens during a power cut?

Automatic lifting on power loss is optional: DS-TMG320-B needs a separately ordered emergency module, and on DS-TMG520 it is not supported by default; the boom can be operated manually with a tool.

Does a parking barrier need a ground loop?

A loop, IR sensor or radar is recommended to stop the boom falling on a vehicle. The DS-TMG320-B and DS-TMG520 datasheets provide a dedicated input for it.

Summary

Choose a Hikvision parking barrier from lane width and peak traffic: DS-TMG320-B for compact residential and office entrances, DS-TMG423-B where a visible fence boom is needed, and DS-TMG520 for heavy traffic and lanes up to 6 m. Then fix the opening method (plate, card or remote), the power-failure behaviour, and prepare the base and conduits before the barrier arrives.

Choosing a barrier for your site entrance? Send us the lane width, expected traffic and the access method you want, and the AZEIDK team will propose the model, boom length and integration with datasheets. Contact AZEIDK GROUP

References: DS-TMG320/B 32 Series Barrier Gates (Hikvision, official datasheet), DS-TMG423-B product page (AZEIDK), DS-TMG520 Barrier gates with straight boom pole (Hikvision, official datasheet)
Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.