Five Vulnerabilities in Some Hikvision Cameras (July 2026): What CCTV Owners Should Do
- News
- 3 min read

On 22 July 2026 the Hikvision Security Response Center (HSRC) published advisory HSRC-202607-01 covering five vulnerabilities in some Hikvision cameras. On the same date, the national CERT of Saudi Arabia’s National Cybersecurity Authority (NCA) issued high-severity alert 2026-7666, asking users to review the vendor advisory and update affected products. Some of the flaws need no login at all, so every owner of a Hikvision-based CCTV system should give this a quick review.
Key points
- Five CVEs: CVE-2026-57599, CVE-2026-57600, CVE-2026-61390, CVE-2026-61391 and CVE-2026-61392.
- The highest score is 7.7 under CVSS v3.1, and three of the five can be exploited without authentication.
- The advisory text does not list models; Hikvision points to an official link with the affected models.
- Fix: update camera firmware. Hikvision recommends its Hikvision Delivery Assistant tool for batch upgrades.
What are the five Hikvision camera vulnerabilities?
| CVE | Type, as described by Hikvision | Score (CVSS v3.1) |
|---|---|---|
| CVE-2026-57599 | Privilege escalation from incorrect permission allocation; full device control after authenticating via SSH | 6.6 |
| CVE-2026-57600 | Insufficient input validation in firmware; an unauthenticated attacker can retrieve partial sensitive data | 7.5 |
| CVE-2026-61390 | Heap buffer overflow; an unauthenticated attacker may cause device malfunction | 7.7 |
| CVE-2026-61391 | Stack-based buffer overflow; an authenticated attacker may cause device malfunction | 7.2 |
| CVE-2026-61392 | Information disclosure; an unauthenticated attacker can obtain partial data from device memory | 5.3 |
Source: Hikvision advisory HSRC-202607-01. Hikvision credits researchers from Inversus Labs and the Bitdefender IoT Security Team.
Are my cameras affected?
The advisory does not name the models in its text. It refers readers to an official Hikvision link that lists the affected models and versions. So it is wrong to assume that every Hikvision camera is affected, and equally wrong to assume a given camera is safe without checking its model and firmware against that list. The model and firmware version are shown in the camera’s web page, in the NVR, or through the SADP tool on the local network.
What it means for facilities in Saudi Arabia
Hikvision cameras are common in Saudi shops, warehouses, residential compounds, schools and healthcare facilities, and many have run for years without a firmware update. The unauthenticated flaws are most serious for cameras exposed directly to the internet, whether through router port forwarding or a public address. The SSH flaw matters for devices where SSH is enabled and protected by a weak or shared password.
Practical steps: list the cameras and their models, check them against Hikvision’s list, update firmware on affected units, close any port forwarded to cameras from the internet and use secure remote access instead, disable SSH if it is not needed, and replace default or shared passwords. Back up the device configuration first, and update one camera before rolling out to the rest.
AZEIDK view
Camera firmware updates belong in routine maintenance, not in emergencies. We recommend adding them to your CCTV maintenance schedule, with a record of each camera’s firmware version and update date. General hardening steps are in how to protect CCTV cameras from hacking, and what to ask for at purchase is in CCTV cybersecurity certifications. For the Hikvision range we supply, see Hikvision cameras in Saudi Arabia, and for complete solutions visit security and surveillance systems. The inventory check and updates can run under our annual maintenance contracts, or you can contact the AZEIDK team.
Sources
- Security Vulnerabilities in some Hikvision Cameras (HSRC-202607-01), Hikvision, 22 July 2026
- Hikvision Alert 2026-7666, National Cybersecurity Authority CERT, 22 July 2026
Related guides
- Recalled Central Sprinkler Heads: New CPSC and Tyco Warning and Why Older Buildings Should Check
- Humain data center Riyadh: 6GW campus infrastructure contract goes to Al-Yamama
- Over 14,500 Dahua Surveillance Devices Hacked via Weak Passwords, Old Flaws and P2P: How to Protect Your CCTV
- UL 864 11th Edition Effective 9 October 2026 per Intertek: What It Means for Fire Alarm Panel Approvals on Saudi Projects