Hikvision AX PRO Add-ons: Keypad, Repeater, Relay Output and Wireless Smoke Detector

Hikvision AX PRO Add-ons: Keypad, Repeater, Relay Output and Wireless Smoke Detector

A Hikvision AX PRO wireless alarm is more than the hub and a few detectors. Large villas, shops with thick walls and warehouses usually need a keypad at the entrance, a repeater to reach far rooms, a relay output to switch a light or a lock, and sometimes a wireless smoke detector. This guide explains what each AX PRO add-on listed on the AZEIDK website does and when you need it: the DS-PK1-LT-WE keypad, the DS-PR1-WE repeater, the DS-PM1-O1L-WE output expander and the DS-PDSMK-E-WE smoke detector, plus the wired DS-PDTT15AM-LM outdoor detector. All figures come from the product pages and official datasheets.

AZEIDK supplies and installs intrusion alarm systems within its security and surveillance systems. If you are still choosing the platform, start with Ajax vs Hikvision AX PRO.

Quick answer

  • Match the frequency first: AX PRO devices come in 868 MHz (WE) and 433 MHz (WB) versions, and every device must match the hub. The add-ons below are WE versions.
  • Arm and disarm at the door with a code or card: DS-PK1-LT-WE keypad.
  • Rooms or buildings beyond the hub’s reach: DS-PR1-WE repeater, mains powered with a backup battery.
  • Switching a light, siren or door lock from the alarm: DS-PM1-O1L-WE relay output.
  • Smoke alarm on the same app: DS-PDSMK-E-WE, with its own 85 dB sounder.
  • Outdoor perimeter on a wired zone: DS-PDTT15AM-LM detector with anti-masking.
In this article
  1. The add-ons compared
  2. When each add-on is needed
  3. Mistakes that cause false alarms or dead zones
  4. Frequently asked questions

The add-ons compared

DeviceJobWireless range (open area)PowerKey points
DS-PK1-LT-WEKeypad1200 mFour CR123 batteries, up to 2 years standbyLCD with LED status, built-in card reader, front and back tamper
DS-PR1-WERepeater2000 m100 to 240 VAC with built-in Li batteryTwo-way 868 MHz, AES-128, wall mount, 170 x 170 x 38.6 mm
DS-PM1-O1L-WERelay output1800 m7 to 24 V DCOne NO/NC relay, 0 to 36 V DC, up to 5 A, 38 x 25 x 18 mm
DS-PDSMK-E-WESmoke detector1600 mSensor batteries up to 10 years, CR123A for the radio up to 5 yearsPhotoelectric, works standalone, sounder at least 85 dB at 3 m
DS-PDTT15AM-LMOutdoor motion detector (wired)Wired, not wireless9 to 16 V DCTwo PIR plus 24 GHz microwave, 15 m, 90 or 180 degrees, anti-masking, IP65, 40 kg pet immunity

Range figures are open-area values from the datasheets. Concrete walls, metal racks and lift shafts cut them a lot, so the signal is checked on site before the devices are fixed.

When each add-on is needed

  • Keypad: the app is enough for owners, but staff, cleaners and guards often need to disarm at the door without a phone. The built-in card reader on the DS-PK1-LT-WE lets them use a card instead of a code.
  • Repeater: for a villa annex, a roof room, a far store or a second floor behind heavy slabs. Because it runs on mains power with a battery, it keeps working through a power cut.
  • Relay output: the DS-PM1-O1L-WE switches a low-voltage circuit, for example an outside light on alarm or an electric lock. It is a low-voltage DC relay, so mains loads need a suitable contactor installed by an electrician.
  • Wireless smoke detector: suits homes, small offices and shops on the AX PRO app. It does not replace a fire alarm system where the building code requires one; see standalone smoke alarm or fire alarm system.
  • Outdoor detector: the DS-PDTT15AM-LM is a wired 12 V detector for perimeter zones of villas, warehouses and yards. Its anti-masking reports attempts to cover the lens. Fitting height on the page is 0.8 to 1.2 m.

Mistakes that cause false alarms or dead zones

  • Mixing WB and WE devices: they will not pair with the hub.
  • Placing the repeater at the edge of the hub’s coverage instead of where both sides have a good signal.
  • Fitting outdoor detectors facing trees or moving signs; see burglar alarm false alarms.
  • Forgetting the siren: an add-on is not a sounder, see alarm siren guide.

Frequently asked questions

How far can the AX PRO keypad be from the hub?

The datasheet gives up to 1200 m in open area. Inside buildings the real distance is much shorter and is checked during installation, with a repeater added when needed.

Can the relay output open a gate?

It provides one NO/NC contact rated 0 to 36 V DC and up to 5 A. It can trigger a gate controller input or a low-voltage lock; the gate controller wiring decides the rest.

Does the wireless smoke detector need the hub to sound?

No. The page describes it as standalone with its own sounder of at least 85 dB at 3 m, and it also sends the alarm wirelessly to the AX PRO system.

Is the DS-PDTT15AM-LM wireless?

No. It is a wired detector powered at 9 to 16 V DC with a normally closed alarm output, so it needs a wired zone input.

Extending or designing an AX PRO alarm? The AZEIDK team surveys the site, places the repeaters and keypads and programs the system. Request a quote

References: Hikvision product pages on the AZEIDK website and Hikvision official datasheets.
Share this article
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.