Hikvision Access Point Vulnerability CVE-2026-16843: Affected DS-3WAP Models and the Firmware Fix

  • News
  • 3 min read
Hikvision Access Point Vulnerability CVE-2026-16843: Affected DS-3WAP Models and the Firmware Fix
AZEIDK RadarWe track the update before it reaches your site
CybersecurityNational Cybersecurity Authority

On 31 July 2026 the Hikvision Security Response Center (HSRC) disclosed CVE-2026-16843, a command execution flaw in some Hikvision networking products, including DS-3WAP series wireless access points. The same day, the national cybersecurity CERT of Saudi Arabia’s National Cybersecurity Authority (NCA) issued high-severity alert 2026-7695 and asked users to review the vendor advisory and update affected products. One of the listed models is the DS-3WAP623E-SI outdoor access point that AZEIDK supplies in Saudi Arabia.

Key points

  • CVE-2026-16843 lets an attacker who already holds valid credentials run commands on the device by sending crafted packets, because input is not validated properly.
  • Hikvision rates it 7.2 under CVSS v3.1; the NCA alert is classed as high severity.
  • Affected models: DS-3WAP521-SI, DS-3WAP522-SI, DS-3WAP621E-SI, DS-3WAP622E-SI, DS-3WAP623E-SI and DS-3WAP622G-SI, plus several DS-3WG models.
  • Fix: install the patched firmware published on Hikvision’s official website.

What is the Hikvision access point vulnerability?

According to advisory HSRC-202607-03, some Hikvision networking products do not validate input sufficiently. An attacker with valid login details can send packets carrying malicious commands and have the device execute them. The credential requirement matters in practice: the devices most exposed are those still running the default admin password, those sharing one password among several technicians, and those whose management page is reachable from a guest network or straight from the internet.

The advisory was first released on 31 July 2026 and updated on 3 August 2026. Hikvision credits an independent security researcher with the report.

Affected models and fixed firmware

ModelsAffected versionFixed version
DS-3WAP521-SI, DS-3WAP522-SI, DS-3WAP621E-SI, DS-3WAP622E-SI, DS-3WAP623E-SI, DS-3WAP622G-SIV1.1.6601 build251223 and earlierV1.1.6602 build260526
DS-3WG105G-SI, DS-3WG105GP-SI, DS-3WG210GP-SI, DS-3WG507G-SIV1.0.6601 build251223 and earlierV1.0.6602 build260703

Source: Hikvision advisory HSRC-202607-03. The running firmware version is shown in the device’s web management page or in the management app used on site.

What it means for facilities in Saudi Arabia

Access points are part of the building network. Many of them cover yards, car parks, compounds and warehouses, and CCTV or time attendance traffic often passes through them. An unpatched unit is therefore not just a Wi-Fi issue but a possible way into the operational network. NCA CERT alerts of this kind are addressed to a wide range of sectors, including energy, healthcare, manufacturing, transport, government and commercial facilities.

The practical steps are simple: list every Hikvision access point on site with its model, compare its firmware with the table above, upgrade to the fixed release, replace default or shared admin passwords, and restrict the management interface to the internal management network.

AZEIDK view

We recommend making access point firmware updates part of every scheduled network maintenance visit rather than waiting for a fault. If you run the Hikvision DS-3WAP623E-SI outdoor access point, start there; our article on the Hikvision DS-3WAP623E-SI outdoor access point covers where it is used. For a new wireless network see our access point guide, and for complete solutions visit network and communication systems. If the same network carries CCTV, how to protect CCTV cameras from hacking completes these steps, and the NCA alert on HikCentral Access Control is another example of why updates matter. Inspection and firmware updates can be covered under our annual maintenance contracts, or you can contact the AZEIDK team.

Sources

  1. Remote Command Execution Vulnerability in Some Hikvision Networking Products (HSRC-202607-03), Hikvision, 31 July 2026 (updated 3 August 2026)
  2. Hikvision Alert 2026-7695, National Cybersecurity Authority CERT, 31 July 2026
Share this article

Back to Media Center

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.