Fire Extinguishing Methods: Cooling, Smothering, Starving and Chain-Breaking, and the System for Each

Fire Extinguishing Methods: Cooling, Smothering, Starving and Chain-Breaking, and the System for Each

All fire extinguishing methods rest on one idea: remove something the fire needs. Fire needs fuel, heat, oxygen and a chemical chain reaction, and each method targets one of them. This explains why water suits one fire and not another, and why server rooms use gas instead of sprinklers.

AZEIDK supplies and installs the matching systems under fire fighting systems and special fire suppression systems. To compare system types for a specific building, see the fire fighting system selection guide.

Key points

  • Cooling removes heat, mainly with water and sprinklers.
  • Smothering cuts off oxygen with foam, CO2 or a fire blanket.
  • Starving removes fuel, such as closing a gas or fuel valve.
  • Chain-breaking stops the reaction, the basis of dry powder and part of some clean agents.
In this article
  1. From the fire triangle to fire extinguishing methods
  2. 1. Cooling
  3. 2. Smothering
  4. 3. Starving
  5. 4. Breaking the chain reaction
  6. Which method fits which space
  7. Frequently asked questions

From the fire triangle to fire extinguishing methods

The fire triangle covers fuel, heat and oxygen, and specialists add the chain reaction as a fourth element. Removing any one stops the fire. See fire triangle and fire classes.

1. Cooling

Water absorbs a great deal of heat as it warms and evaporates, bringing burning material below the temperature needed to keep burning. It is the most common method in buildings because it suits solid materials. Systems: automatic sprinklers, hose cabinets, outdoor hydrants and water extinguishers. Not for live electrical equipment or liquid fires it may spread.

2. Smothering

Smothering keeps oxygen away by covering the surface or lowering oxygen in the space. Systems: foam for fuel tanks and hangars, CO2 for normally unoccupied areas, and fire blankets in kitchens. See what is firefighting foam and fire blankets.

3. Starving

Starving cuts the fuel supply or moves unburnt material away. In a gas fire, closing the valve is the real extinguishment; putting out the flame while gas still leaks is dangerous. Systems: gas shut-off valves linked to kitchen suppression or gas detection, fuel line isolation valves, and storage layouts with aisles.

4. Breaking the chain reaction

Some agents interfere with the combustion chemistry and stop it fast. This is the basis of dry powder and contributes to clean agents such as HFC-227ea alongside heat absorption. Systems: powder extinguishers, fixed powder systems and clean agent systems. See clean agent suppression.

Which method fits which space

SpaceMain methodUsual system
Offices, shops, general storageCoolingSprinklers, hose cabinets, extinguishers
Fuel tanks and hangarsSmotheringFoam systems and monitors
Server and electrical roomsHeat absorption, chain-breaking or oxygen reductionClean agent or inert gas
Commercial kitchensCooling, smothering and starvingHood suppression with gas shut-off
Generator roomsSmotheringCO2 or foam as designed

Frequently asked questions

What are the fire extinguishing methods?

Cooling, smothering, starving and breaking the chain reaction.

Which method is most used in buildings?

Cooling with water through sprinklers and hose cabinets.

Why not use water on an oil fire?

Water sinks under the oil and flashes to steam, throwing burning oil out. Smother it instead.

How does dry powder work?

Mainly by breaking the combustion chain reaction, with some smothering.

How is a gas fire extinguished?

By starving it first, closing the gas source, then dealing with any remaining flame.

Want the right system for your facility? Send us the activity and hazard areas, and AZEIDK will propose a system for each area. Contact AZEIDK

Share this article