Fire Safety in Exhibitions and Conference Halls in Egypt: Booths and Extinguishers

Fire Safety in Exhibitions and Conference Halls in Egypt: Booths and Extinguishers

Within a few days an exhibition hall turns from an empty space into a small town of temporary booths, each with its own scenery, lighting, power connections and cartons of stock. Then thousands of visitors arrive, and then everything is dismantled. Fire safety in exhibitions and conference halls is therefore about managing those few days, not only about the building design.

This article covers temporary booths, temporary electrical connections and the right fire extinguishers for each booth and area, plus detection and alarm in large halls, within the solutions AZEIDK Egypt supplies to organisers, venue managers and exhibitors.

Key takeaways

  • NFPA 10 lists product displays in convention centres among its extra hazard examples, so a hall needs more extinguishers during a show than an empty conference hall.
  • Temporary electrical connections in booths need the closest control during build-up and the show.
  • Packaging cartons behind booths and in aisles add fire load and must leave the hall.
  • Large high halls suit beam detectors, and covered booths can block detection.
  • The binding reference is the Egyptian fire code (2026 edition) together with Civil Protection requirements.
In this article
  1. What changes in the hall during a show?
  2. Fire safety in exhibitions: temporary electrics
  3. Extinguishers: for each booth and each area
  4. Detection and alarm in exhibition halls
  5. Aisles, exits and hose cabinets
  6. The Egyptian framework
  7. The three stages: build-up, show days and dismantling
  8. Common mistakes at exhibitions
  9. Frequently asked questions
  10. Conclusion

What changes in the hall during a show?

An empty exhibition hall is simple from a fire point of view: a high roof, open space and little content. Once build-up starts, timber, plywood, fabric, carpet, foam and illuminated signs come in, hundreds of metres of temporary cable are laid, and cartons pile up behind the booths. Carpenters and electricians from different companies work in the hall at the same time, and some may use cutting or welding tools.

During the show the load peaks: finished booths, lighting on for hours, coffee machines and screens, sometimes live cooking demonstrations, and visitors who do not know the building. Then dismantling happens in a few hours, when waste builds up in the aisles.

Fire safety in exhibitions: temporary electrics

Most of what can be prevented at an exhibition is electrical. These are good practices the venue can require from exhibitors and booth contractors:

  • Each booth takes power from a supply point approved by the venue, with a breaker sized for its declared load.
  • Sound cables and extension leads of suitable rating, with no extension plugged into another extension.
  • No exposed cables across aisles; any that must cross are protected and fixed.
  • Hot luminaires kept away from fabric and plastic signs.
  • Power to booths switched off after closing each day, except equipment that must run continuously and is approved by the venue.
  • Any cutting or welding during build-up only with a venue permit and an extinguisher next to the worker.

Extinguishers: for each booth and each area

NFPA 10 lists product displays in convention centres among its extra hazard examples, while assembly halls are light hazard examples. For extra hazard the standard sets a minimum 4-A rating, a maximum of 92.9 m2 per unit of A and a travel distance of no more than 22.9 m. In other words, the same hall needs more extinguishers during a show than during a conference without booths. A suggested layout:

AreaSuggested extinguisher
Hall aisles and near exits6 or 9 kg ABC dry powder from PYRAMID based on the area calculation
Large or two-storey boothAn ABC dry powder extinguisher inside the booth, known to the exhibitor’s team
Electronics and screen boothsAn additional CO2 extinguisher
Live cooking demonstrationsAn extinguisher suited to cooking oils as designed, and no oil stored in the booth
Electrical rooms and booth supply boardsCO2, plus an automatic CO2 unit in small closed rooms
Loading bay and stores12 kg ABC dry powder, and wheeled dry powder in large areas
Conference and seminar rooms6 kg ABC dry powder near exits

PYRAMID dry powder and CO2 extinguishers conform to the relevant Egyptian standard for each type and are approved by the Egyptian Organization for Standardization and Quality (EOS). To calculate the number by area, see how many fire extinguishers you need and where.

Detection and alarm in exhibition halls

Exhibition halls are high and wide, and ceiling point detectors are far from booth level and hard to maintain. A beam detector such as the TANDA TX7130, designed for large, high spaces, is often used. Our article on beam detector spacing explains how distances are set. The beam path must stay clear: no banners, balloons or tall scenery hung across it.

Covered or two-storey booths can keep smoke away from the hall ceiling detectors if a fire starts underneath them. The alarm engineer should review this with the venue when large booth designs are approved. In halls with several zones, an addressable ZFP panel from Context Plus helps locate the alarm quickly, with sounders and beacons that can be heard and seen over the noise of the show.

Conference rooms attached to an exhibition centre are simpler on seminar days: fixed or stacked seats, a screen and a sound and interpreting booth. But they fill quickly and the lights go down during presentations, so exit signs must stay lit, the sound and interpreting booth needs a CO2 extinguisher, and no extra rows of chairs should be added that narrow the gangways between seats or in front of the doors.

Aisles, exits and hose cabinets

The floor plan sets aisle widths and booth positions, and it should stay as approved: no tables, banners or cartons in aisles, and no booth scenery covering a hose cabinet, extinguisher or exit sign. Check this every day before the doors open. In halls with a firefighting network, hose cabinets and the fire department (Siamese) connection must stay visible and easy to reach, and the Siamese connection area must not be used to park delivery vehicles.

The Egyptian framework

The binding reference is the Egyptian Code for the Design and Implementation of Fire Protection for Buildings, 2026 edition (Ministerial Decree No. 355 of 2026), with drawings and inspections approved by the General Directorate of Civil Protection (Ministry of Interior). Each venue may also set its own safety rules for exhibitors. NFPA is a technical reference used by designers.

The three stages: build-up, show days and dismantling

Each stage has its own risks, and it is easier for the venue to tie its checks to the stage:

StageMain risksWhat to check
Build-upCutting and welding, sawdust, loose cables, cartonsHot work permits, an extinguisher with every crew, daily waste removal
Show daysElectrical loads, crowding, cooking demosAisles and exits before opening, supply points, power off at night
DismantlingWaste in aisles, lifts and vehicles in the hallExits and hose cabinets kept clear until the last booth leaves

It helps if the venue gives exhibitors and booth contractors a short guide with these rules before build-up, with the contact of the venue safety officer, and checks that large booths have their extinguishers before opening day, not after. After the show, check the alarm panel and beam detectors, because dismantling can knock reflectors out of line or leave dust that affects the devices.

Common mistakes at exhibitions

  • Extension leads plugged into each other inside the booth to run lighting and screens.
  • Packaging cartons stacked behind booths until the show ends.
  • Booth scenery covering a hose cabinet or extinguisher.
  • Banners hung across the beam detector path.
  • Live cooking demonstrations without a suitable extinguisher next to them.
  • Booth power left on all night.

Frequently asked questions

Does every booth need its own extinguisher?

Large booths, two-storey booths and cooking booths should have their own. The general layout in the aisles is calculated by area and hazard level.

What hazard level is an exhibition hall in NFPA 10?

NFPA 10 lists product displays in convention centres among its extra hazard examples, so the minimum extinguisher rating is 4-A.

Which detector suits a high exhibition hall?

Usually a beam detector such as the TANDA TX7130, with the beam path kept clear of banners and scenery.

Do covered booths affect the alarm?

Yes. They can keep smoke away from ceiling detectors if a fire starts below them, so the alarm engineer reviews this when booth designs are approved.

What is the most preventable cause at exhibitions?

Poor temporary electrical connections, such as daisy-chained extension leads and exposed cables across aisles.

Who is responsible for safety in a booth?

The exhibitor and the booth contractor are responsible for their booth under the venue rules, and the venue is responsible for aisles and building systems.

Conclusion

Fire safety in exhibitions and conference halls means managing build-up, show days and dismantling: sound temporary electrics, extinguishers calculated on extra hazard during the show, beam detectors with a clear path, visible aisles, exits and hose cabinets, and cartons removed from the hall as they arrive.

Running an exhibition venue or organising a show soon? Send us the hall and booth plan, and we will propose the number and layout of extinguishers and what the alarm system needs. Talk to the AZEIDK Egypt team

References: NFPA 10 Second Draft Report, A2025 cycle (NFPA), PYRAMID (AZEIDK Egypt), TANDA (AZEIDK Egypt)