A motion detector (PIR motion sensor) is the device in a burglar alarm system that picks up a person moving inside a room or corridor while the system is armed, and reports the alarm to the control panel. Most indoor detectors use passive infrared (PIR). Within its intrusion alarm systems range, AZEIDK supplies three wireless models: the Hikvision DS-PDP15P-EG2-WE, the Ajax Superior MotionProtect Jeweller and the Paradox PMD75M.
This guide explains how a motion detector works, how the three models differ according to their product data, where to mount them, why they sometimes trigger with no intruder, and how to pick a model that matches the panel you already have.
Key points
- A PIR detector senses the heat change caused by a body moving across its field of view. It does not detect a person standing completely still.
- Hikvision DS-PDP15P: 15 m range, 85.9° coverage, pet immunity up to 30 kg, for the AX PRO system.
- Ajax Superior MotionProtect: up to 12 m when mounted at 2.4 m, ignores pets up to 20 kg and 50 cm tall, for Ajax hubs.
- Paradox PMD75M: two opposed sensors, 11 × 11 m coverage, Grade 2 to EN 50131, for the Paradox M system.
- A wireless detector only works with a panel of the same brand and frequency, so choose the panel first.
In this article
- What is a PIR motion detector and how does it work?
- Motion detector specifications: Hikvision, Ajax and Paradox
- Pet-immune motion detectors: how do they ignore cats?
- Where to install a motion detector: height, angle and places to avoid
- Why does a motion detector give false alarms?
- How to choose the right motion detector for your system
- How many motion detectors do you need?
- FAQ
What is a PIR motion detector and how does it work?
PIR stands for passive infrared. The detector emits nothing. It receives the infrared (heat) radiation given off by objects in its view. A segmented lens in front of the sensor divides the room into zones, and when a warm body moves from one zone to the next, the reading changes quickly and the detector reports motion.
That is why a PIR detector catches someone walking across its view more easily than someone walking straight towards it, and why it cannot see a person who stays perfectly still. Manufacturers also state the speed range they detect: 0.3 to 2 m/s for the Hikvision DS-PDP15P and 0.2 to 3.5 m/s for the Paradox PMD75M.
A wireless detector runs on a battery and sends the alarm by radio to the panel, so no cable runs are needed. That makes it the usual choice in existing villas, apartments and shops where the owner does not want walls opened.
Motion detector specifications: Hikvision, Ajax and Paradox
The table below uses the product data published on AZEIDK’s product pages, taken from each manufacturer’s official datasheet:
| Item | Hikvision DS-PDP15P-EG2-WE | Ajax Superior MotionProtect | Paradox PMD75M |
|---|---|---|---|
| Detection | PIR | PIR | Two opposed PIR sensors |
| Range | 15 m | Up to 12 m (mounted at 2.4 m) | 11 × 11 m, centre beam 15 m |
| Coverage angle | 85.9° | 88.5° horizontal | 90° |
| Pet immunity | Up to 30 kg | Up to 20 kg and 50 cm tall | Supported |
| Radio | 868 MHz (WE), AES-128; AX PRO also comes in a 433 MHz (WB) version | Jeweller, 868.0 to 868.6 MHz | 868 or 914 MHz by version |
| Open-air radio range | 1.6 km | Up to 1,700 m | Not stated on the page |
| Battery | 1 × CR123A, up to 5 years standby | 1 × CR123A, up to 5 years | 3 × AAA lithium, 6+ years |
| Operating temperature | -10 to 55 °C | -10 to 40 °C | -20 to 40 °C |
| Note | Mounting height 1.8 to 2.4 m | IP50, IK04, 3 sensitivity levels | Grade 2, EN 50131 |
The figures are not always directly comparable, as each manufacturer measures range its own way. What matters is that the detector covers the room with some margin and works with your panel.
Pet-immune motion detectors: how do they ignore cats?
In homes with cats or small dogs, a standard detector produces repeated alarms. All three detectors here offer pet immunity, each with a stated limit: 30 kg for Hikvision, and 20 kg with a height under 50 cm for Ajax.
The feature assumes the animal moves on the floor. A cat that jumps onto a sofa or shelf, or passes close to the detector, can still be read as a person. Mount the detector so it does not face furniture the animal climbs, and keep to the manufacturer’s height, because a different height changes how the detection zones fall.
Where to install a motion detector: height, angle and places to avoid
- Height: 1.8 to 2.4 m for the Hikvision DS-PDP15P; Ajax states its range at 2.4 m. Follow the datasheet.
- Angle: the expected intruder path should cross the detector’s view, for example a corner mount that sees the door and window from the side.
- Corridors: one detector at the end of a corridor catches anyone entering, as long as the length is within the stated range.
- Heat sources: do not aim it at an AC outlet, a heater or a window with direct sun.
- Glass: PIR cannot see through glass, so a detector inside a shopfront will not detect someone outside it.
Outdoor protection for gardens and boundary walls uses different detectors, covered in our guide to outdoor motion detectors for perimeter protection.
Why does a motion detector give false alarms?
The usual causes are hot air from an AC unit or heater, sunlight moving across the floor, a pet heavier than the stated limit, a moving curtain, or an insect on the lens. A weak battery or a detector too far from the panel can also cause faults.
The fix starts with the mounting position, then the sensitivity setting in the app where the detector supports it (Ajax offers 3 levels). Step-by-step troubleshooting is in our article on burglar alarm false alarms.
How to choose the right motion detector for your system
Rule one: a wireless detector follows the panel. Ajax detectors work with Ajax hubs such as the Hub 2 Plus; the Hikvision DS-PDP15P is made for AX PRO; the Paradox PMD75M connects to the Paradox M system. You cannot pair a detector from one brand with another brand’s panel by radio.
Rule two: matching frequency. The detector and panel must use the same band, so check the full model code before ordering, as some brands sell the same model in more than one frequency.
- For larger pets, the 30 kg limit on the Hikvision model is the highest of the three.
- If the project specification asks for a grade under the European standard EN 50131, check each model’s stated grade. The PMD75M page states Grade 2.
- A large warehouse or hall may need several detectors rather than one.
If you are building a new system, start with our guide to designing an Ajax burglar alarm system, or read about the Paradox hybrid alarm panel if you have existing wiring.
How many motion detectors do you need?
There is no fixed number. A practical approach: one detector in each room with an external window or door, one in the corridor anyone must pass between the entrance and the rest of the premises, and one in the room holding the safe or valuable stock. In a shop, one detector often covers the sales floor if it is within range, plus one in the back store.
Motion detectors complement door and window contacts: the contact alarms the moment a door opens, while the motion detector catches someone who came in another way. A balanced system uses both. See intrusion alarm systems for the full set of components.
FAQ
Does a motion detector detect someone standing still?
No. A PIR detector reacts to the heat change caused by movement. A person who stays completely still does not change the reading.
Does a wireless motion detector need mains power?
No. All three models run on batteries: CR123A for Hikvision and Ajax, three AAA lithium cells for Paradox.
Can I pair a Hikvision detector with an Ajax hub?
No. Each brand uses its own radio protocol, so a wireless detector only works with a panel of the same brand and frequency.
What is the correct mounting height?
Follow the manufacturer: 1.8 to 2.4 m for the Hikvision DS-PDP15P, and Ajax states its range at 2.4 m. A wrong height reduces detection or raises false alarms.
Can I install a motion detector near an air conditioner?
Avoid aiming it at heat sources or AC outlets, as sudden warm or cold air can trigger a false alarm.
How long does the battery last?
Per the product pages: up to 5 years standby for the Hikvision DS-PDP15P, up to 5 years for Ajax, and over 6 years for the Paradox PMD75M with normal use. Real life depends on activity and temperature.
Need help placing your detectors? Send us the floor plan and the panel you already have, if any, and we will propose compatible detectors with their datasheets. Contact AZEIDK
For a site survey or quotation, see CCTV supply and installation.
Related guides
- Fire Protection in University Student Housing: Room Detectors, Sprinklers and Shared Kitchens
- Workplace Safety Rules for Offices, Warehouses and Kitchens: A Practical Checklist
- Fire Protection for Warehouses and Logistics Facilities in Saudi Arabia
- Jack Pump or WATEX? Comparing the UL-Listed Fire Pumps Available from AZEIDK in Saudi Arabia