Fire Protection & Life Safety
Fire Alarm SystemsAddressable and conventional detection and alarm→Fire Fighting SystemsSprinkler networks, fire pumps and components→Special Fire Suppression SystemsGas and aerosol systems for sensitive equipment→Kitchen Fire Suppression SystemsHood and cooking equipment protection→Smoke Extraction & Emergency VentilationSmoke control to keep escape routes usable→Fire-Rated Doors & Emergency ExitsFire-rated doors and exit hardware→Electromechanical & Contracting
HVAC, Electrical & Plumbing WorksElectromechanical (MEP) works coordinated with fire protection and low current systems→Smart Buildings & Systems IntegrationNetworks, CCTV, access control, fire alarm and BMS working as one→General ContractingProject delivery and trade coordination, with life safety built in from day one→Engineering delivery process
Regulatory & compliance support

Fire Alarm Systems
Addressable and conventional fire alarm systems, designed, installed and tested by AZEIDK
Need the right engineering solution?
Talk to the AZEIDK Team →
Coming soon to AZEIDK Saudi Arabia.
SAFEGUARD BIOSOLV C6 AFFF-1% in a 200-liter HDPE drum is an aqueous film-forming foam concentrate for extinguishing and securing flammable hydrocarbon and select oxygenated fuel fires. It is formulated with hydrocarbon surfactants, fluorocarbon surfactants, solvents, preservatives and buffers, and helps prevent re-ignition after extinguishment.
The concentrate is proportioned at 1%: 1 part foam concentrate to 99 parts water.
Key features:
• Forms a thin aqueous film across the fuel surface, separating the fuel from oxygen.
• Fast knockdown, burn-back resistance and post-fire security.
• For flammable hydrocarbon fuel fires at 1%.
• Can be used with fresh, brackish and sea water.
• Compatible with dry chemical powder extinguishing agents.
• UL listed (UL file EX26577) and LR approved.
• Conforms to US-MIL, ICAO, FM, DEF STAN and EN, as stated in the data sheet.
Typical properties:
• Appearance: amber liquid.
• pH: 6.5 to 8.5.
• Expansion: greater than 8.0.
• 25% drainage time: greater than 90 seconds.
• Viscosity: less than 20 cps.
• Spreading coefficient: greater than 3.0.
• Fire performance: meets US specification.
Proportioning equipment:
• Balanced and in-line balanced pressure pump proportioners.
• Balanced pressure bladder tanks and ratio flow controllers.
• Around-the-pump proportioners.
• Fixed or portable in-line venturi proportioners.
• Hand-line nozzles with fixed eductors or pick-up tubes.
Typical applications:
• Fuel storage tanks.
• Process areas.
• Power stations.
• Marine terminals.
• Offshore platforms.
• Areas where hydrocarbon fuels and chemicals are stored, processed or transported.
Storage and handling:
• Store in a dry, well-ventilated place, out of direct sunlight.
• Stack HDPE containers preferably in a single layer, and no more than two layers.
• Recommended storage temperature: −5°C to 49°C. Container label: min. 20°F (−6.7°C), max. 120°F (49°C).
• For bulk tanks, keep the tank full with 5–10% space for thermal expansion; inlet at the base, outlet above the base.
• Recommended tank materials: stainless steel 304/316 and cross-linked HDPE. Uncoated mild steel is not recommended.
Environmental information:
• Biodegradable and low in toxicity, as stated in the data sheet.
• Can be treated in sewage treatment plants in consultation with the relevant local authority.
Packaging:
• 200 liters, HDPE drum.
• The 1% concentrate is also supplied in 20, 30 and 200 liter containers.
AFFF-1% must not be used undiluted. Confirm compatibility with the fuel, system design and proportioning equipment before use, and refer to the attached technical data sheet.
View the product’s full specifications and technical information in the official catalogue.