Potter VSR Vane Type Waterflow Alarm Switch with Retard – UL / FM

Vane type waterflow switch with a 0–90 second field replaceable retard and two SPDT contacts, UL listed and FM approved models for steel sprinkler pipe.
Brand
potter vsr

Product Details

Product Overview

The Potter VSR is a vane type waterflow alarm switch that detects water flow in wet pipe sprinkler systems and signals the fire alarm panel. A field replaceable retard with an easy-to-read adjustment knob delays the alarm from 0 to 90 seconds to avoid false alarms from pressure surges. The manufacturer warns that waterflow switches on wet systems must not be the sole initiating device for discharging AFFF, deluge or chemical suppression systems.

Key features

  • 0–90 second field replaceable time delay retard
  • UL listed models for 2″–6″ steel pipe schedules 5 through 40
  • UL listed and FM approved models for 2″–8″ steel pipe schedules 10 through 40
  • Two SPDT (Form C) contacts with clear terminal markings
  • Weatherproof, assembled in USA

Typical applications

Floor and zone flow detection on sprinkler risers and branch lines in hospitals, malls, hotels, towers and warehouses, connected through monitor modules to addressable fire alarm panels.

Supply and support from AZEIDK

AZEIDK supplies this product in Saudi Arabia with technical selection, submittal preparation, installation, testing and commissioning, and annual maintenance through its engineering team, showrooms and warehouses in Jeddah, Riyadh and Dammam. Send your drawings, BOQ or specification to receive a technical and commercial offer.

Applications and Building Types

The Potter VSR Vane Type Waterflow Alarm Switch is designed for floor and zone flow detection on sprinkler risers and branch lines. It is suitable for installation in hospitals, malls, hotels, towers, and warehouses. This device detects water flow in wet pipe sprinkler systems and signals the fire alarm panel. It connects through monitor modules to addressable fire alarm panels, ensuring reliable monitoring of sprinkler zones across various commercial and institutional structures in Saudi Arabia.

Key Technical Features

  • Vane type waterflow switch with a 0–90 second field replaceable retard
  • Easy-to-read adjustment knob to delay alarms and avoid false triggers from pressure surges
  • Two SPDT (Form C) contacts with clear terminal markings
  • UL listed models for 2″–6″ steel pipe schedules 5 through 40
  • UL listed and FM approved models for 2″–8″ steel pipe schedules 10 through 40
  • Weatherproof design and assembled in USA

AZEIDK Support and Services

AZEIDK supplies the Potter VSR in Saudi Arabia with comprehensive technical support. Our engineering team provides technical selection, submittal preparation, and installation services. We also handle testing and commissioning to ensure system integrity. Annual maintenance contracts are available to keep your fire protection systems operational. With showrooms and warehouses in Jeddah, Riyadh, and Dammam, we offer efficient local support. Please send your drawings, BOQ, or specification to receive a technical and commercial offer.

Technical Documents

Product Catalogue

View the product’s full specifications and technical information in the official catalogue.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.