aj pipe HDPE PE100 Pipe SDR 9 PN 20 for Underground Fire Water Mains

aj pipe (Abuljadayel Factory, Jeddah) HDPE PE100 pressure pipe, SDR 9, PN 20 bar, OD 20 to 560 mm to DIN 8074 and ISO 4427, supplied by AZEIDK for underground fire water mains.
Brand
aj pipe HDPE PE100 Pipe SDR 9 PN 20 for Underground Fire Water Mains

Product Details

Product Overview

HDPE pipe from aj pipe, the brand of Abuljadayel Factory for GRP & PE Pipes in Jeddah Industrial City, Saudi Arabia. This class is made of PE100 at SDR 9 with a nominal pressure of PN 20 bar, to DIN 8074, DIN 8075 and ISO 4427.

AZEIDK includes these pipes in material submittals for underground fire water networks, such as buried fire mains and ring mains feeding fire hydrants. The pressure class and the acceptance of the material in a fire network depend on the project specification, the consultant and Civil Defense requirements.

Specifications

MaterialHigh density polyethylene PE100
ClassSDR 9, Series 4
Nominal pressurePN 20 bar (safety factor 1.25 for water pipes, per the manufacturer table)
Outside diameters20 to 560 mm
StandardsDIN 8074, DIN 8075, ISO 4427
Lengths12 m standard lengths for OD 110 to 630 mm, coils up to OD 110 mm
ApplicationPressure water lines

Wall thickness and weight (SDR 9, PN 20)

Outside diameter (mm)Nominal wall thickness (mm)Nominal weight (kg/m)
202.30.133
252.80.200
323.60.327
404.50.509
505.60.788
637.11.26
758.41.76
9010.12.54
11012.33.78
125144.87
14015.76.11
16017.97.96
18020.110.1
20022.412.4
22525.215.8
25027.919.4
28031.324.3
31535.230.8
35539.739.1
40044.749.6
45050.362.7
50055.877.3
56062.597.0

Weights are calculated with an average density of 0.950 g/cm³, as stated in the manufacturer table.

Standards and tests

  • PE100 material, dimensions to DIN 8074 and requirements to DIN 8075.
  • International standard ISO 4427, adopted in Saudi Arabia as SASO ISO 4427.
  • Material suitability for contact with water tested to BS 6920.
  • Test reports from HENZE and HESSEL laboratories in Germany, Bodycote Polymer in Sweden and Intertek in the UK.

Factory documents and test reports are attached in the datasheet.

FAQ

What does SDR 9 mean?

It is the ratio of outside diameter to wall thickness. A lower number means a thicker wall and a higher nominal pressure, so PE100 at SDR 9 gives PN 20 bar.

Are these pipes FM approved or UL listed?

The submittal we hold does not include an FM or UL certificate. If the project requires listed pipe, confirm this before ordering.

Does the factory supply fittings?

The manufacturer states it can supply all required fittings with the pipes. AZEIDK confirms the fittings needed from the project drawings.

For a quotation or a full project submittal, contact AZEIDK.

Technical Documents

Product Catalogue

View the product’s full specifications and technical information in the official catalogue.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.