The Falcon Gold single-door stainless steel fire hose reel cabinet is a complete enclosure designed to house and protect a swinging fire hose reel, hose, valve and adjustable nozzle inside buildings and facilities.
This page combines two models from the same product family:
• FG-1001S for surface-mounted installation.
• FGR-1001S for recessed installation.
The primary difference between the two models is the mounting method and cabinet-body construction, while both use a similar swinging hose reel assembly.
FG-1001S Model:
The FG-1001S is a single-door, surface-mounted fire hose reel cabinet.
Its cabinet body and door are manufactured from SUS 304 stainless steel with a stated thickness of 1.2 mm.
Main dimensions:
• Width: 800 mm.
• Height: 800 mm.
• Depth: 230 mm.
The cabinet is mounted directly onto the wall and includes rear fixing holes and bottom drainage openings.
FGR-1001S Model:
The FGR-1001S is a single-door recessed fire hose reel cabinet designed for installation inside the wall.
The shown construction includes:
• SUS 304 stainless steel front architrave and door.
• 1.2 mm stainless steel thickness.
• Brushed stainless steel front finish.
• Powder-coated mild-steel rear body.
• Red RAL 3000 rear-body finish.
• Approximate internal cabinet size of 800 × 800 × 230 mm.
• Approximate external frame size of 880 × 880 mm.
The recessed arrangement reduces projection into corridors and public areas while retaining a stainless steel architectural appearance.
Swinging Hose Reel Assembly:
The cabinet contains a swinging manual hose reel that allows the hose to be pulled out and directed toward the fire location.
The assembly shown includes:
• Hose reel disc.
• Hub.
• Long screw rod.
• Manual waterway.
• Swinging arm.
• Crimping sleeve.
• Inlet joint.
• Inlet hose.
• Connector.
• Angle valve.
• Adjustable nozzle.
• Fire hose.
• Protective spring.
• Outlet joint.
Hose and Reel Specifications:
• Hose diameter: 25 mm.
• Hose length: 30 meters.
• Reel diameter: 600 mm.
• Bracket length: 290 mm.
• Reel width: 150 mm.
• Maximum hose working pressure shown: 12 bar.
• Average burst pressure stated: up to 45 bar.
Waterway:
The reel uses a full brass waterway for corrosion resistance and secure water delivery.
The catalogue states that threaded nipples are used at selected connections rather than hose clamps to improve joint sealing and reduce leakage risk.
Swinging Mechanism:
The swinging arm allows the reel to move outward and helps the user direct the hose toward the protected area.
The catalogue describes endurance testing including:
• More than 3,000 reel rotations without visible leakage.
• Swinging movement to a minimum angle of approximately 170 degrees.
• At least 1,000 swinging cycles without visible leakage or damage.
Adjustable Nozzle:
The nozzle can be adjusted between:
• Jet stream.
• Spray pattern.
• Shut-off position.
Applications:
• Commercial buildings.
• Residential complexes.
• Hotels.
• Hospitals.
• Schools and universities.
• Office buildings.
• Shopping centers.
• Industrial facilities.
• Warehouses.
• Parking facilities.
• Government buildings.
• Internal corridors and service areas.
Key Benefits:
• Single-door configuration.
• Surface-mounted and recessed installation options.
• Stainless steel front appearance.
• Corrosion-resistant materials.
• Swinging fire hose reel.
• 30-meter fire hose.
• Adjustable jet and spray nozzle.
• Stainless steel round lock.
• Printed operating instructions.
• Rolled reel-disc edges for safer handling.
• Powder-coated and ultraviolet-resistant reel discs according to the catalogue.
• Installation and drainage openings according to model design.
Materials and Finishes:
FG-1001S:
• Cabinet body: SUS 304 stainless steel.
• Door: SUS 304 stainless steel.
• Thickness: 1.2 mm.
• Finish: Brushed stainless steel.
FGR-1001S:
• Front door and architrave: SUS 304 stainless steel.
• Stainless steel thickness: 1.2 mm.
• Rear cabinet body: Mild steel.
• Rear-body finish: Red RAL 3000 powder coating.
Approval Shown:
The catalogue presents LPCB product approval according to:
• EN 671-1:2012.
• LPCB Certificate Reference 1038a.
The supplied model, configuration, components and approval marking must be verified against the project and authority requirements at the time of procurement.
Operating Procedure:
1. Open the water valve.
2. Pull the hose toward the fire.
3. Open and adjust the nozzle to jet or spray.
4. Direct the water at the base of the fire.
5. Close the valve after use.
6. Drain the remaining water from the hose.
7. Rewind the hose and close the nozzle.
Required Procurement Information:
• FG-1001S or FGR-1001S model.
• Surface-mounted or recessed installation.
• Cabinet material and finish.
• Door-opening direction.
• Water-inlet direction.
• Valve type and size.
• Nozzle type.
• Hose diameter and length.
• Required approval.
• Project and consultant requirements.
• Required quantity.
Installation Notes:
• Install the cabinet on a wall or supporting structure suitable for its operating weight.
• Confirm that the cabinet is level and correctly aligned.
• Provide adequate clearance for door opening and reel swinging.
• Maintain unobstructed access to the valve and nozzle.
• Connect the water supply according to approved drawings.
• Perform pressure and leakage testing after installation.
• Do not obstruct reel or hose movement.
• Keep the operating instructions clearly visible.
• Protect stainless steel surfaces from scratches during installation.
• Installation and commissioning must be completed by qualified personnel.
Maintenance:
• Inspect the cabinet, door and lock periodically.
• Confirm smooth door operation.
• Check swinging reel movement.
• Inspect the hose for cracks, wear or damage.
• Test the nozzle in jet and spray modes.
• Check the valve and fittings for leakage.
• Inspect the cabinet for corrosion or physical damage.
• Perform periodic operational testing.
• Rewind the hose correctly after every test or use.
Important Note:
FG-1001S and FGR-1001S are grouped under one product page because they form the same Falcon Gold single-door stainless steel fire hose reel cabinet family.
The primary option is the mounting method: surface mounted or recessed.
Refer to the attached catalogue for detailed drawings, dimensions, components and approval documentation. Confirm the final configuration through the approved manufacturer’s submittal before procurement.
اطّلع على البيانات والمعلومات الفنية الكاملة للمنتج من خلال الكتالوج الرسمي.
Explore more products available in this category.