TYCO Series DS-1 Dry-Type Fire Sprinklers – TY3155, TY3255 and TY3355

TYCO Series DS-1 dry-type fire sprinklers with a 5.6 K-factor and standard response, available in pendent, upright and horizontal-sidewall models for freezing environments.
العلامة التجارية
TYCO Series DS-1 Dry-Type Fire Sprinklers – TY3155, TY3255 and TY3355

تفاصيل المنتج

نظرة عامة على المنتج

TYCO Series DS-1 Dry-Type Fire Sprinklers are automatic sprinklers designed for installations where the sprinkler, connecting piping or protected area may be exposed to freezing temperatures.

This product page combines three models from the same sprinkler family:

• TY3255: Pendent.
• TY3155: Upright.
• TY3355: Horizontal Sidewall.

All three models use the same dry-type operating mechanism, 5.6 K-factor, standard response and standard coverage classification. Their primary differences are installation orientation and deflector configuration.

Series DS-1 sprinklers are commonly used on dry-pipe systems or as extensions from wet-pipe systems into freezers, cold rooms, exterior canopies, loading docks and other unheated spaces.

Key Features:

• Dry-type automatic fire sprinklers.
• TYCO Series DS-1.
• Nominal K-factor of 5.6.
• Standard Response.
• Standard Coverage.
• 5 mm glass bulb.
• Available in pendent, upright and horizontal-sidewall configurations.
• Suitable for freezing environments.
• Suitable for dry-pipe systems.
• Suitable for wet-system extensions into freezers and cold spaces.
• Suitable for exterior canopies, loading docks and unheated buildings.
• 1-inch NPT or ISO 7-R 1 inlet connection.
• Maximum working pressure of 175 PSI.
• Available in multiple manufactured lengths.
• Standard, deep and no-escutcheon options according to model.
• Natural brass, chrome-plated and polyester-coated finishes.
• UL Listed.
• C-UL Listed.
• FM Approved.
• LPCB Approved.
• CE Certified.
• Intended for systems designed in accordance with NFPA 13.

Available Models:

TY3255 Pendent:

A dry-type pendent sprinkler installed through ceilings where the branch line is located in a heated area and the protected space below may be exposed to freezing temperatures.

Typical applications include:

• Freezers.
• Cold rooms.
• Exterior canopies.
• Unheated ceiling spaces.
• Dry-pipe systems requiring pendent sprinklers.

TY3155 Upright:

A dry-type upright sprinkler designed for installations where the system layout requires an upright deflector while the sprinkler barrel remains protected from freezing conditions.

Typical applications include:

• Unheated storage areas.
• Cold warehouses.
• Dry-system extensions.
• Locations where upright orientation is required.

TY3355 Horizontal Sidewall:

A dry-type horizontal-sidewall sprinkler installed through a wall, allowing the supply connection to remain in a protected area while providing coverage into an exterior or freezing environment.

Typical applications include:

• Loading docks.
• Exterior canopies.
• Balconies.
• Entrances.
• Unheated areas adjacent to buildings.
• Horizontal extensions through exterior walls.

Operation:

Under normal standby conditions, the inlet plug and sealing assembly prevent water from entering the dry sprinkler barrel.

When the rated temperature is reached:

• Fluid inside the glass bulb expands.
• The bulb shatters.
• The bulb seat is released.
• The compressed internal spring expands.
• The spring pushes the water tube and guide tube outward.
• The yoke withdraws the inlet plug and sealing assembly.
• Water enters the sprinkler barrel.
• Water discharges through the sprinkler.
• The deflector distributes water according to the selected orientation.

Discharge Coefficient:

• K-factor: 5.6 GPM/psi½.
• Metric K-factor: 80.6 LPM/bar½.

Response Classification:

• Standard Response.
• 5 mm glass bulb.

Coverage Classification:

• Standard Coverage.

Maximum Working Pressure:

• 175 PSI.
• 12.1 bar.

Inlet Connections:

• 1-inch NPT.
• ISO 7-R 1.

Available Temperature Ratings:

• 155°F / 68°C – Red bulb.
• 175°F / 79°C – Yellow bulb.
• 200°F / 93°C – Green bulb.
• 286°F / 141°C – Blue bulb.
• 360°F / 182°C – Mauve bulb.

Approved temperatures may vary by model, escutcheon type and finish. Refer to the approval tables before final selection.

Main Construction Materials:

• Inlet: Copper.
• Plug: Copper.
• Yoke: Stainless steel.
• Casing: Galvanized carbon steel.
• Insert: Bronze.
• Bulb seat: Stainless steel.
• Bulb: 5 mm glass.
• Compression screw: Bronze.
• Deflector: Bronze.
• Frame: Bronze.
• Guide tube: Stainless steel.
• Water tube: Stainless steel.
• Spring: Stainless steel.
• Sealing assembly: Beryllium nickel with PTFE.
• Escutcheon: Carbon steel or stainless steel.

Escutcheon Options:

Depending on model and installation, options include:

• Standard escutcheon.
• Deep escutcheon.
• Without escutcheon.
• Ceiling-specific arrangements.
• Wall arrangements for horizontal-sidewall models.

Available Finishes:

• Natural brass.
• Chrome plated.
• Polyester coated.

Corrosion-resistant listing status varies by sprinkler type, temperature rating and finish.

Manufactured Lengths:

Series DS-1 sprinklers are supplied in different order lengths to suit the distance between the branch line and the finished ceiling or wall.

The required length is determined by:

• Ceiling depth.
• Wall thickness.
• Pipe-fitting position.
• Ambient temperature.
• Minimum exposed-barrel length required to prevent freezing.
• Selected escutcheon type.

Order length must be measured according to the catalogue drawings because the sprinkler is manufactured to the specified length and should not be field modified.

Fitting Requirements:

Install 1-inch NPT DS-1 sprinklers only in suitable approved fittings, including:

• Malleable or ductile-iron threaded tees complying with ANSI B16.3 Class 150.
• Cast-iron threaded tees complying with ANSI B16.4 Class 125.
• Selected GRINNELL fittings under the conditions stated in the catalogue.
• Specified TYCO CPVC fittings for applicable wet-pipe installations.

Do not install Series DS-1 sprinklers into elbow fittings. The sprinkler inlet may contact the inside of the elbow and impair operation.

Dry-pipe installations must be arranged to allow complete drainage above the sprinkler and branch line to prevent trapped water from freezing.

Installation Orientation:

TY3255 Pendent:

• Install only in the pendent orientation.
• The deflector must be parallel to the ceiling.

TY3155 Upright:

• Install only in the upright orientation.
• The deflector must be parallel to the ceiling.

TY3355 Horizontal Sidewall:

• Install horizontally.
• The waterway centerline must be perpendicular to the back wall.
• The waterway must be parallel to the ceiling.
• The word TOP on the deflector must face the ceiling.

Installation Tools:

The sprinkler can be tightened using:

• A pipe wrench applied to the designated inlet band or casing.
• A W-Type 7 sprinkler wrench applied to the sprinkler wrench flat.

Do not apply installation tools to the frame, bulb or deflector.

After the ceiling or wall finish is completed, slide the outer escutcheon piece into contact with the surface without lifting the ceiling panel from its normal position.

Applications:

• Freezers.
• Cold-storage rooms.
• Industrial refrigeration areas.
• Cold warehouses.
• Dry-pipe sprinkler systems.
• Exterior canopies.
• Loading docks.
• Open parking areas.
• Unheated building sections.
• Balconies and exterior entrances.
• Wet-system extensions into freezing areas.
• Systems seasonally drained to avoid freezing.

Standards and Approvals Shown in the Catalogue:

• UL Listed.
• C-UL Listed.
• FM Approved.
• LPCB Approved – Reference 094a/11.
• CE Certified – Certificate 2831-CPR-S2015.
• NFPA 13.
• ANSI B16.3 Class 150.
• ANSI B16.4 Class 125.

Important Notes:

Models TY3155, TY3255 and TY3355 are combined under one product because they belong to the same Series DS-1 family and use the same dry operating mechanism. The primary difference is installation orientation and deflector design.

The final model, order length, temperature rating and escutcheon must be selected according to installation orientation, ambient temperature, piping system type, hydraulic calculations, project specifications and authority requirements.

Do not use a sprinkler with an exposed length below the required minimum in freezing environments, as cold conduction may reach water-filled piping.

Refer to the complete approval and order-length tables before procurement and installation.