{"id":35432,"date":"2026-11-29T12:02:49","date_gmt":"2026-11-29T09:02:49","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-29T12:25:01","modified_gmt":"2026-11-29T09:25:01","slug":"jack-pump-diesel-fire-pump-skid-nfpa20","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/jack-pump-diesel-fire-pump-skid-nfpa20\/","title":{"rendered":"Jack Pump Diesel Fire Pump Skid to NFPA 20: Components, Options and What to Check Before Ordering"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"35432\" class=\"elementor elementor-35432 elementor-35431 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e401bc e-con-full az-el-article e-flex e-con e-parent\" data-id=\"6e401bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7288098 elementor-widget elementor-widget-text-editor\" data-id=\"7288098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>A diesel fire pump skid<\/strong> means the fire pump and the diesel engine are mounted and aligned on one base plate and tested at the factory before shipping. This guide explains the Jack Pump packaged diesel skid built to NFPA 20: what it includes, the engine, controller and accessory options, and what to check before ordering and installing it, based on the official Jack Pump catalogue.<\/p>\n<p>The skid is available from AZEIDK as part of our <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>. Details and the datasheet are on the <a href=\"\/en\/sa\/products\/jack-pump-diesel-driven-fire-pump-skid\/\">Jack Pump diesel driven fire pump skid page<\/a>, and the other pumps are on the <a href=\"\/en\/brand\/jack-pump\/\">Jack Pump page<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89ee07a elementor-widget elementor-widget-text-editor\" data-id=\"89ee07a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>A listed and approved centrifugal fire pump with a listed and approved diesel engine, on one coated hot rolled mild steel base plate.<\/li><li>The skid is built around an end suction or a split case pump, as the project requires.<\/li><li>Diesel engines in the catalogue: Black Stallion 15 to 390 HP or Kirloskar 62 to 330 HP, both UL Listed and FM Approved.<\/li><li>Skid packages are tested and inspected at the factory before release.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f91091f elementor-widget elementor-widget-text-editor\" data-id=\"f91091f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What is a packaged diesel fire pump skid?<\/h2>\n<p>In a traditional installation the pump and engine are supplied separately, the base is built and the shaft alignment is set on site. A skid arrives assembled: pump and engine directly coupled and aligned on a single base plate with a fabricated C-channel frame and anchor bolt holes. The Jack Pump catalogue notes the compact footprint suits existing pump rooms for retrofit.<\/p>\n<p>For the code components of a diesel fire pump, see <a href=\"\/en\/sa\/media-center\/diesel-fire-pump-components-nfpa20\/\">diesel fire pump components per NFPA 20<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da403c0 elementor-widget elementor-widget-text-editor\" data-id=\"da403c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Skid components and options<\/h2>\n<div class=\"az-table-wrap\"><table>\n<thead><tr><th>Item<\/th><th>What the catalogue states<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Pump<\/td><td>End suction pump 50 to 1000 US GPM up to 230 psi, or a split case pump as the project requires<\/td><\/tr>\n<tr><td>Diesel engine<\/td><td>Black Stallion 15 to 390 HP at 1400 to 3000 RPM, or Kirloskar 62 to 330 HP at 1760 to 3000 RPM<\/td><\/tr>\n<tr><td>Controller<\/td><td>Tornatech, UL Listed and FM Approved, or the customer&#8217;s choice of Firetrol or Hubbell<\/td><\/tr>\n<tr><td>Air relief valve<\/td><td>Val-Matic, 1\/2 to 2 inch, up to 300 psi<\/td><\/tr>\n<tr><td>Flow meter<\/td><td>Gerand, FM Approved, 2-1\/2 to 8 inch, up to 300 psi<\/td><\/tr>\n<tr><td>Base<\/td><td>One piece coated hot rolled mild steel with a heavy C-channel frame<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The catalogue also states that listed Jack Pump pumps can be coupled with any other listed diesel engine on request, and that its controllers are factory assembled and tested to UL 218. For Tornatech options, see <a href=\"\/en\/sa\/media-center\/tornatech-fire-pump-controllers-gpx-gpd\/\">GPx and GPD controllers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb2eadd elementor-widget elementor-widget-text-editor\" data-id=\"fb2eadd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When to choose a packaged diesel skid<\/h2>\n<ul>\n<li>When you need a main or standby pump that does not depend on the power supply, as explained in <a href=\"\/en\/sa\/media-center\/electric-vs-diesel-fire-pumps\/\">electric vs diesel fire pumps<\/a>.<\/li>\n<li>When replacing an old pump in a tight room, since the skid is compact and arrives aligned.<\/li>\n<li>When the owner or consultant wants less alignment work on site, because coupling and testing are done at the factory.<\/li>\n<\/ul>\n<p>To choose the pump type itself, see <a href=\"\/en\/sa\/media-center\/jack-pump-fire-pump-types\/\">Jack Pump fire pump types<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41ec23e elementor-widget elementor-widget-text-editor\" data-id=\"41ec23e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What to check before ordering<\/h2>\n<h3>Duty point<\/h3>\n<p>The flow and pressure from the hydraulic calculations set the pump type and engine power. See <a href=\"\/en\/sa\/media-center\/fire-pump-calculation-sizing-nfpa-20\/\">fire pump sizing per NFPA 20<\/a>.<\/p>\n<h3>Certificates<\/h3>\n<p>Ask for UL and FM certificates for the pump, engine and controller, the pump performance curve and the factory test report for the skid in the submittal.<\/p>\n<h3>Pump room<\/h3>\n<p>Skid footprint with service clearances, fuel tank, ventilation, exhaust and suction and discharge piping. See the <a href=\"\/en\/sa\/media-center\/fire-pump-room\/\">fire pump room guide<\/a>.<\/p>\n<h3>Civil Defense requirements<\/h3>\n<p>Design and testing follow the approved drawings and the building&#8217;s Civil Defense requirements, which AZEIDK follows up through its <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f2dca6 elementor-widget elementor-widget-text-editor\" data-id=\"5f2dca6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation and commissioning<\/h2>\n<p>On arrival the skid is anchored to its concrete foundation, then suction, discharge, fuel, exhaust and controller connections are made, alignment is checked again after piping, and the running and flow tests follow. The steps are in <a href=\"\/en\/sa\/media-center\/fire-pump-installation-steps\/\">fire pump installation step by step<\/a>. AZEIDK carries out <a href=\"\/en\/sa\/services\/installation-implementation\/\">installation<\/a>, <a href=\"\/en\/sa\/services\/testing-commissioning-handover\/\">testing and handover<\/a> and <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3072e1 elementor-widget elementor-widget-text-editor\" data-id=\"f3072e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<h3>How does a diesel skid differ from buying the pump and engine separately?<\/h3><p>On a skid the pump and engine arrive coupled and aligned on one base and tested at the factory, so there is less alignment work on site.<\/p>\n<h3>Which diesel engines are offered with the Jack Pump skid?<\/h3><p>Per the catalogue: Black Stallion 15 to 390 HP or Kirloskar 62 to 330 HP, both listed and approved.<\/p>\n<h3>Can the skid use a split case pump?<\/h3><p>Yes. The catalogue shows a diesel skid with an end suction pump and another with a split case pump; the type follows the required flow.<\/p>\n<h3>Which controller is used?<\/h3><p>Tornatech, listed and approved, or the customer&#8217;s choice of Firetrol or Hubbell.<\/p>\n<h3>Is the skid tested before delivery?<\/h3><p>Yes. The catalogue states skid packages are tested and inspected before release, and a site test follows installation.<\/p>\n<h3>Is there an electric motor skid?<\/h3><p>The Jack Pump catalogue also shows a motor driven skid with WEG motors. Ask AZEIDK what is available for your project.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7729a43 elementor-widget elementor-widget-text-editor\" data-id=\"7729a43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need a diesel fire pump skid for a new building or to replace an existing pump?<\/strong> Send AZEIDK the duty point and drawings, and we will propose the pump, engine and controller. Read also: <a href=\"\/en\/sa\/media-center\/clarke-diesel-fire-pump-engines\/\">Clarke diesel engines<\/a> and <a href=\"\/en\/sa\/media-center\/diesel-fire-pump-engine-maintenance\/\">diesel fire pump engine maintenance<\/a>. <a href=\"\/en\/sa\/contact\/\">Request a quote from AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Jack Pump diesel fire pump skid: listed pump and diesel engine on one base, factory tested, with engine, controller and accessory options and checks.<\/p>\n","protected":false},"author":0,"featured_media":35538,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,320],"tags":[],"azeidk_region":[223],"class_list":["post-35432","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-codes-certifications-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/35432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=35432"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/35432\/revisions"}],"predecessor-version":[{"id":35471,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/35432\/revisions\/35471"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/35538"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=35432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=35432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=35432"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=35432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}