{"id":34750,"date":"2026-11-28T18:13:13","date_gmt":"2026-11-28T15:13:13","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-28T18:13:18","modified_gmt":"2026-11-28T15:13:18","slug":"grundfos-fire-pump-sets","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/grundfos-fire-pump-sets\/","title":{"rendered":"Grundfos Fire Pumps: Fire DNF and Fire HSEF Sets and Vertical Turbine Fire Pumps"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"34750\" class=\"elementor elementor-34750 elementor-34749 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2efbcbe e-con-full az-el-article e-flex e-con e-parent\" data-id=\"2efbcbe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11cee50 elementor-widget elementor-widget-text-editor\" data-id=\"11cee50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Grundfos fire pumps<\/strong> are not only supplied as a bare pump but as a complete fire pump set on one base frame with the driver and the controller. This article covers the types Grundfos publishes officially, including the Fire DNF end-suction set, the Fire HSEF horizontal split-case set and vertical turbine fire pumps, and what each one includes according to the data sheets.<\/p>\n<p>Grundfos is one of the suppliers AZEIDK works with on <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">firefighting system<\/a> projects, within <a href=\"\/en\/sa\/services\/technical-selection-of-systems-equipment\/\">technical selection of systems and equipment<\/a>, <a href=\"\/en\/sa\/services\/technical-supply-of-fire-safety-systems\/\">technical supply<\/a> and <a href=\"\/en\/sa\/services\/installation-implementation\/\">installation<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40bd688 elementor-widget elementor-widget-text-editor\" data-id=\"40bd688\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>Grundfos states that it supplies end-suction, horizontal split-case, vertical split-case, vertical in-line and vertical turbine fire pumps.<\/li><li>The electric (50 Hz) Fire DNF and Fire HSEF sets are FM approved according to NFPA 20 per the data booklet, and are built to order.<\/li><li>Grundfos vertical turbine fire pumps are UL listed and FM approved, with flows from 500 to 5000 GPM and pressures up to 350 psi.<\/li><li>A complete set includes the controller and a circulation relief valve, with a flowmeter available as an accessory.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73134cb elementor-widget elementor-widget-text-editor\" data-id=\"73134cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire DNF and Fire HSEF: what is the difference?<\/h2>\n<table><thead><tr><th>Set<\/th><th>Pump type<\/th><th>What Grundfos states<\/th><\/tr><\/thead><tbody><tr><td>Fire DNF<\/td><td>End-suction<\/td><td>DNF non-self-priming, single-stage centrifugal volute pump with dimensions and rated performance to DIN 24256 and ISO 2858, mounted with the motor on a base plate<\/td><\/tr><tr><td>Fire HSEF<\/td><td>Horizontal split-case<\/td><td>HSEF horizontal split-case centrifugal pump with the motor on a base plate<\/td><\/tr><\/tbody><\/table>\n<p>End-suction pumps usually suit smaller flows, while horizontal split-case pumps cover higher flows and are easier to open for service. The choice starts from the duty point in the hydraulic calculations and from the water source, as explained in the <a href=\"\/en\/sa\/media-center\/fire-pump-types-selection-saudi\/\">fire pump types and selection guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-318d1c7 elementor-widget elementor-widget-text-editor\" data-id=\"318d1c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Grundfos vertical turbine fire pumps<\/h2>\n<p>A vertical turbine pump is used when the water level is below the pump, such as deep underground tanks and wells. The Grundfos fire systems brochure lists:<\/p>\n<ul><li>Flows from 500 to 5000 GPM (114 to 1136 m\u00b3\/h).<\/li><li>Pressure up to 350 psi (24.1 bar).<\/li><li>Engine or electric motor drive, no priming needed and a small floor space.<\/li><li>For the diesel version: a UL listed and FM approved engine with an industrial silencer, heat exchanger cooling, a fuel tank sized to NFPA 20 and an FM listed right angle gear.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e37ddf elementor-widget elementor-widget-text-editor\" data-id=\"6e37ddf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Controllers and starting methods<\/h2>\n<p>Grundfos states that the controllers in its sets are UL-FM approved as standard and use microprocessor logic with a pressure and event recorder. Starting options for the electric controller include star delta, part winding, soft start, autotransformer and variable frequency drive. For selection criteria see <a href=\"\/en\/sa\/media-center\/fire-pump-controller-selection\/\">fire pump controller selection<\/a>, and for an example of standalone controllers see <a href=\"\/en\/sa\/media-center\/tornatech-fire-pump-controllers-gpx-gpd\/\">Tornatech GPx and GPD controllers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb7b03a elementor-widget elementor-widget-text-editor\" data-id=\"bb7b03a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Approvals: look at the model, not the brand<\/h2>\n<p>Grundfos lists a long set of approvals across its products, including UL, FM, NFPA 20, LPCB, VdS and EN 12845. Each approval, however, belongs to a specific model, size and driver; the Fire DNF and Fire HSEF data booklet, for example, covers FM approved 50 Hz versions. Ask for the approval reference of the exact model supplied and check it as in <a href=\"\/en\/sa\/media-center\/fire-pump-ul-fm-approval-check\/\">how to check a fire pump&#8217;s UL and FM approval<\/a>. For the wider market picture, see <a href=\"\/en\/sa\/media-center\/fire-pump-brands-saudi-arabia\/\">fire pump brands in Saudi Arabia<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80d2b90 elementor-widget elementor-widget-text-editor\" data-id=\"80d2b90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>After supply: testing and commissioning<\/h2>\n<p>Every fire pump set needs an on-site acceptance test to NFPA 20 before handover, then weekly runs and periodic maintenance. See <a href=\"\/en\/sa\/media-center\/fire-pump-acceptance-testing-commissioning\/\">fire pump acceptance testing and commissioning<\/a> and the <a href=\"\/en\/sa\/media-center\/nfpa-20-fire-pumps-standard-guide\/\">NFPA 20 guide<\/a>, and for diesel drivers see <a href=\"\/en\/sa\/media-center\/clarke-diesel-fire-pump-engines\/\">Clarke diesel fire pump engines<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe05795 elementor-widget elementor-widget-text-editor\" data-id=\"fe05795\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<h3>Are Grundfos fire pumps UL listed and FM approved?<\/h3><p>Grundfos states that its electric and diesel systems are UL listed and FM approved, and that the 50 Hz Fire DNF and Fire HSEF sets are FM approved according to NFPA 20. Always check the exact model.<\/p>\n<h3>What comes with a Fire DNF or Fire HSEF set?<\/h3><p>The pump and motor on a base plate, a controller and a circulation relief valve, with a flowmeter approved by FM or UL available as an accessory.<\/p>\n<h3>When should I choose a vertical turbine pump?<\/h3><p>When the water source is below the pump, such as a deep underground tank or a well, because it needs no priming.<\/p>\n<h3>Does AZEIDK supply Grundfos fire pumps?<\/h3><p>Grundfos is one of the suppliers AZEIDK works with, and the model is chosen to the project specification. See our <a href=\"\/en\/sa\/products\/?product_category=fire-pumps\">fire pumps section<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ce2448 elementor-widget elementor-widget-text-editor\" data-id=\"6ce2448\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Choosing a fire pump for your project?<\/strong> Send AZEIDK the required flow and pressure and the type of water source, and our team will compare the options and prepare the submittal. <a href=\"\/en\/sa\/contact\/\">Request a quote from AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Grundfos fire pumps: the Fire DNF end-suction set, the Fire HSEF horizontal split-case set and vertical turbine fire pumps, approvals, controllers and checks.<\/p>\n","protected":false},"author":0,"featured_media":34734,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-34750","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/34750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=34750"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/34750\/revisions"}],"predecessor-version":[{"id":34756,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/34750\/revisions\/34756"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/34734"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=34750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=34750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=34750"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=34750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}