{"id":33869,"date":"2026-11-28T01:39:31","date_gmt":"2026-11-27T22:39:31","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-28T01:40:36","modified_gmt":"2026-11-27T22:40:36","slug":"fm200-clean-agent-cost-factors-egypt","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/eg\/media-center\/fm200-clean-agent-cost-factors-egypt\/","title":{"rendered":"FM-200 System Cost in Egypt: What Drives the Price, from Room Volume to Maintenance and Recharge"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"33869\" class=\"elementor elementor-33869 elementor-33868 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2335ab2 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"2335ab2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8463532 elementor-widget elementor-widget-text-editor\" data-id=\"8463532\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">Many people ask for the <strong>price of an FM-200 system<\/strong> for an electrical or server room before the room has been measured. A clean agent system is not priced per square metre: the cost is built from the volume of each protected space, the design concentration, the number of cylinders, the detection and release method, room tightness, and then maintenance and recharge over the system life. This guide explains those factors without price figures, and how to request a quotation you can compare.<\/p>\n<p>AZEIDK Egypt supplies the AFC-227 system from <a href=\"\/en\/eg\/brands\/american-fire-control\/\">American Fire Control<\/a> under <a href=\"\/en\/eg\/solutions\/special-fire-suppression-egypt\/\">special fire suppression<\/a>, with submittals, supply, installation, testing and maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c0ba5d elementor-widget elementor-widget-text-editor\" data-id=\"6c0ba5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>The first cost driver is agent quantity, calculated from the net volume of each space, the concentration and the lowest temperature, not from floor area.<\/li><li>Raised floor and ceiling voids are calculated as separate spaces and add agent and nozzles.<\/li><li>A complete quotation states the model, cylinders, detection, release panel, room integrity test and documents explicitly.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4271f32 elementor-widget elementor-widget-text-editor\" data-id=\"4271f32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>1. Protected volume and agent quantity<\/h2>\n<p>Agent mass in kg equals net volume divided by the specific vapour volume, multiplied by concentration over (100 minus concentration), with the specific volume taken at the lowest expected room temperature. Two rooms with the same area but different heights therefore need different quantities. Details and a worked example are in <a href=\"\/en\/eg\/media-center\/clean-agent-quantity-calculation-egypt\/\">clean agent quantity calculation<\/a>.<\/p>\n<p>If the room has a raised floor or a ceiling void carrying cables, each space is calculated by its own volume, the quantities are added and each space needs its own nozzles. Most Egyptian cities are close to sea level, so the altitude factor is about 1.00; elevated sites are corrected.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5428a26 elementor-widget elementor-widget-text-editor\" data-id=\"5428a26\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>2. Cylinders, count and system type<\/h2>\n<p>AFC-227 cylinders range from 26.8 litres water capacity (AFC-26) to 175 litres (AFC-175); the calculated quantity sets the number and size of cylinders. Where pipe runs are long or complex, the AFC-P227 model with a separate nitrogen pusher cylinder may be needed, starting from AFC-P63, as decided by the hydraulic calculation report. See <a href=\"\/en\/eg\/media-center\/afc-227-clean-agent-system-egypt\/\">the AFC-227 \/ P227 system<\/a>.<\/p>\n<p>Where several adjacent rooms are protected, they may share the same cylinders through selector valves that direct the agent to the room that sent the release signal. That changes the sum: cylinders sized for the largest room, plus extra valves and pipework.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef44da1 elementor-widget elementor-widget-text-editor\" data-id=\"ef44da1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>3. Detection and the release control panel<\/h2>\n<p>The system does not work without detection and release: detectors in each space, a release control panel, pre-alarm devices, a manual release button, and signs. The release sequence and its devices are a separate line in the quotation, with the model stated and whether it is linked to the building fire alarm. See <a href=\"\/en\/eg\/media-center\/clean-agent-fire-suppression-egypt\/\">clean agent fire suppression<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6add9b8 elementor-widget elementor-widget-text-editor\" data-id=\"6add9b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>4. Room tightness and the door fan test<\/h2>\n<p>Gas cannot protect a room that leaks air. The room integrity test measures leakage and predicts how long the room holds the concentration without discharging any agent; if the room fails, openings are sealed, doors and dampers adjusted and the test repeated. The test and sealing works may sit with the contractor or the owner, so define this in the quotation. See <a href=\"\/en\/eg\/media-center\/room-integrity-test-egypt\/\">room integrity testing<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9bc5af elementor-widget elementor-widget-text-editor\" data-id=\"f9bc5af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>5. Approvals and documents<\/h2>\n<p>Most AFC-227 components are UL and FM approved, with exceptions such as the optional discharge pressure switch and the instruction signs, so check each part on its sheet. The submittal for the consultant, the calculation report and the drawings are all part of the scope and should appear in the quotation. See <a href=\"\/en\/eg\/media-center\/fire-equipment-technical-documents-egypt\/\">fire equipment technical documents<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c16ad8 elementor-widget elementor-widget-text-editor\" data-id=\"3c16ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>6. Cost over the system life<\/h2>\n<p>After installation there are recurring costs: cylinder weighing and pressure checks at least every six months under NFPA 2001, release sequence testing without discharge, and refilling a cylinder when agent loss exceeds 5%. After any discharge the cylinders are removed and transported for filling, and a cylinder whose last hydrostatic test is more than 5 years old is not refilled before it is tested. See <a href=\"\/en\/eg\/media-center\/siyanat-nizam-fm200-egypt\/\">FM-200 system maintenance<\/a> and <a href=\"\/en\/eg\/media-center\/iadat-shahn-fm200-baad-altafrigh-egypt\/\">recharge after discharge<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d289a5 elementor-widget elementor-widget-text-editor\" data-id=\"7d289a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to request a comparable quotation<\/h2>\n<ul><li>Dimensions of each room and the raised floor and ceiling void heights, plus the lowest expected temperature.<\/li><li>The number of rooms and whether they should share one system with selector valves.<\/li><li>The type of protected equipment and whether the room is occupied.<\/li><li>The condition of doors, openings and dampers, and whether the integrity test is in scope.<\/li><li>The reference required by the specification and the component approvals.<\/li><\/ul>\n<p>Then compare quotations line by line: the same calculated quantity, the same number and model of cylinders, and the same scope of detection, release, testing and documents, as in the <a href=\"\/en\/eg\/media-center\/fire-system-quotations-comparison-egypt\/\">fire system quotation comparison guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-536b0ae elementor-widget elementor-widget-text-editor\" data-id=\"536b0ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<h3>Can the price of an FM-200 system be known from room area?<\/h3>\n<p>Not accurately. The cost follows the net volume of each space, the concentration and the minimum temperature, then cylinder count, detection and release, and the integrity test.<\/p>\n<h3>Is CO2 a cheaper alternative?<\/h3>\n<p>Prices may differ, but CO2 concentrations are lethal in occupied spaces, so it is not a like-for-like alternative in a room staff enter. The design decides by hazard and occupancy.<\/p>\n<h3>Does AZEIDK Egypt publish a price list for gas systems?<\/h3>\n<p>No. Each system is priced after the quantity is calculated for each space and the scope is defined; the AZEIDK Egypt team quotes once it has the room data.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a9de28 elementor-widget elementor-widget-text-editor\" data-id=\"3a9de28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>The cost of an FM-200 or AFC-227 system in Egypt is built from a calculated agent quantity for each space, the number and size of cylinders, the detection and release method, room tightness and its test, and the documents, then maintenance and recharge. Ask for a quotation built on these lines so that you compare like with like.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59f37ff elementor-widget elementor-widget-text-editor\" data-id=\"59f37ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Want a quotation for a gas suppression system?<\/strong> Send the room dimensions, the raised and suspended voids and the type of equipment, and the AZEIDK Egypt team will calculate the quantity and propose an AFC-227 system with datasheets. <a href=\"\/en\/eg\/contact\/\">Request a quotation from AZEIDK Egypt<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef78f8f elementor-widget elementor-widget-text-editor\" data-id=\"ef78f8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-sources\"><h2>Sources<\/h2><ol><li><a href=\"\/en\/eg\/brands\/american-fire-control\/\">AZEIDK Egypt American Fire Control brand page<\/a><\/li><li><a href=\"\/en\/eg\/solutions\/special-fire-suppression-egypt\/\">AZEIDK Egypt special fire suppression page<\/a><\/li><\/ol><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>What drives FM-200 \/ AFC-227 system cost in Egypt: room volume, concentration, cylinders, selector valves, detection, integrity testing and maintenance.<\/p>\n","protected":false},"author":0,"featured_media":33836,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[288],"tags":[],"azeidk_region":[226],"class_list":["post-33869","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-eg-engineering-guides"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33869","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=33869"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33869\/revisions"}],"predecessor-version":[{"id":33890,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33869\/revisions\/33890"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/33836"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=33869"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=33869"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=33869"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=33869"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}