{"id":33176,"date":"2026-11-27T21:09:43","date_gmt":"2026-11-27T18:09:43","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-27T21:10:48","modified_gmt":"2026-11-27T18:10:48","slug":"context-plus-cfp-conventional-panel-models","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/context-plus-cfp-conventional-panel-models\/","title":{"rendered":"Context Plus CFP Conventional Fire Alarm Panel: 2, 4 and 8 Zone Models, Relay Cards, Repeater, and When to Choose FP or MFP"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"33176\" class=\"elementor elementor-33176 elementor-33175 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7802e76 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"7802e76\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce9f196 elementor-widget elementor-widget-text-editor\" data-id=\"ce9f196\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>The Context Plus CFP conventional fire alarm panel<\/strong> is the smallest conventional panel in the range: 2, 4 or 8 zones in a plastic enclosure for flush or surface mounting. It is often requested for shops, offices, small warehouses and villas, and the same questions keep coming up: can it be expanded, how many sounder circuits does it have, how do I connect it to HVAC or door release, and when should I choose an FP or MFP panel instead? This guide answers with figures from the product pages and the datasheet published on the AZEIDK site.<\/p>\n<p>AZEIDK is the exclusive agent for Context Plus in Saudi Arabia and supplies and installs CFP panels and accessories as part of its <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm systems<\/a>. Conventional panels are listed in the <a href=\"\/en\/sa\/products\/?product_category=conventional-fire-alarm-systems\">conventional fire alarm category<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7fbf0e5 elementor-widget elementor-widget-text-editor\" data-id=\"7fbf0e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>Three non-expandable models: CFP702-4\/CON with 2 zones, CFP704-4\/CON with 4 zones and CFP708-4\/CON with 8 zones.<\/li><li>LPCB certified to EN54 parts 2 and 4 according to the catalogue, with a 1.5 A EN54-4\/A2 power supply.<\/li><li>Four conventional sounder circuits, fire and fault relays, two open-collector outputs, and class-change and alert inputs.<\/li><li>Extra outputs through internal cards: CFP762 with four common relays, CFP763 adding eight zonal relays, and CFP764, CFP765 and CFP766 with one relay per zone.<\/li><li>Up to eight CFP760\/CON repeaters per panel.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ba3575 elementor-widget elementor-widget-text-editor\" data-id=\"2ba3575\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The three CFP models<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Model<\/th><th>Zones<\/th><th>Matching zonal relay card<\/th><\/tr><\/thead><tbody>\n<tr><td>CFP702-4\/CON<\/td><td>2 (non-expandable)<\/td><td>CFP766 (2 zonal relays)<\/td><\/tr>\n<tr><td>CFP704-4\/CON<\/td><td>4 (non-expandable)<\/td><td>CFP765 (4 zonal relays)<\/td><\/tr>\n<tr><td>CFP708-4\/CON<\/td><td>8 (non-expandable)<\/td><td>CFP764 (8 zonal relays) or CFP763<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Shared features per the <a href=\"\/en\/sa\/products\/cfp-2-8-zone-conventional-fire-alarm-panels\/\">CFP 2 to 8 zone panels<\/a> page: a plastic enclosure for flush or surface mounting without an extra bezel, colour-coded buttons, keypad and keyswitch access to level 2, end-of-line units supplied (one per zone), and engineering functions including zone test, coincidence, zone delay and non-latching zones depending on the model. The panels work with Context Plus Series 65A, Series 65E and ActiV conventional detectors.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c1bf47 elementor-widget elementor-widget-text-editor\" data-id=\"3c1bf47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How do you connect a CFP panel to other systems?<\/h2>\n<p>The panel itself has a fire relay, a fault relay and two outputs for remote and reset functions. If you need more signals for HVAC, lifts, door release or a BMS, add a relay card inside the panel from the <a href=\"\/en\/sa\/products\/cfp-relay-output-zonal-relay-cards-cfp762-cfp766\/\">CFP762 to CFP766 relay cards<\/a> page:<\/p>\n<ul><li><strong>CFP762:<\/strong> four panel-controlled relays: reset, fault, auxiliary fire and remote.<\/li><li><strong>CFP763:<\/strong> the same four relays plus eight zonal relays.<\/li><li><strong>CFP764, CFP765 and CFP766:<\/strong> one relay per zone for the 8, 4 and 2 zone panels, changing over when its zone is in alarm.<\/li><\/ul>\n<p>The fault relay is fail-safe and normally energised, so it signals a fault if the panel loses power. The card outputs are not designed to switch mains voltage, so an interposing relay is needed for power loads. General interfacing with lifts and HVAC is covered in <a href=\"\/en\/sa\/media-center\/addressable-input-output-module-fire-alarm-interface\/\">fire alarm input\/output modules<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b12b616 elementor-widget elementor-widget-text-editor\" data-id=\"b12b616\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The CFP760\/CON repeater<\/h2>\n<p>The <a href=\"\/en\/sa\/products\/cfp-8-zone-repeater-panel-cfp760-con\/\">CFP760\/CON repeater<\/a> repeats the level 1 and level 2 functions of the main panel at another location, such as the fire brigade entrance or the security room. Up to eight repeaters can be connected to one CFP panel over screened two-wire fire resistant cable with a total length up to 1 km. Each repeater has its own power supply and batteries and comes with a CFP761 card, and one more CFP761 card is needed in the main panel. When a repeater is needed is covered in <a href=\"\/en\/sa\/media-center\/fire-alarm-repeater-panel-xfp-fp-cfp\/\">fire alarm repeater panels<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2270a4 elementor-widget elementor-widget-text-editor\" data-id=\"b2270a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>CFP, FP or MFP?<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>CFP<\/th><th>FP<\/th><th>MFP<\/th><\/tr><\/thead><tbody>\n<tr><td>Zones<\/td><td>2, 4 or 8<\/td><td>1 to 8, plus two models expandable from 4 to 6 and from 8 to 14<\/td><td>16, expandable to 20, 24 or 28<\/td><\/tr>\n<tr><td>Enclosure<\/td><td>Plastic, flush or surface<\/td><td>Metal with lift-off lid<\/td><td>Metal with lift-off lid<\/td><\/tr>\n<tr><td>Sounder circuits<\/td><td>4<\/td><td>2<\/td><td>4<\/td><\/tr>\n<tr><td>Stated approval or standard<\/td><td>EN54-2 and 4 by the LPCB<\/td><td>Designed to comply with BS 5839 Part 4<\/td><td>Designed to comply with BS 5839 Part 4<\/td><\/tr>\n<tr><td>Fire and fault outputs<\/td><td>Built in, more with cards<\/td><td>Through an optional expansion loom<\/td><td>Through the MFPX loom<\/td><\/tr>\n<tr><td>Repeaters<\/td><td>Up to 8 (CFP760)<\/td><td>FF396-2 and FF398-2 repeaters<\/td><td>Up to 8 (FF596 with FF596T)<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>FP figures are from the <a href=\"\/en\/sa\/products\/fp-1-14-zone-conventional-fire-alarm-panels\/\">FP 1 to 14 zone panels<\/a> page and MFP figures from the <a href=\"\/en\/sa\/products\/mfp-16-28-zone-conventional-fire-alarm-panel-ff516-con\/\">MFP 16 to 28 zone panel<\/a> page.<\/p>\n<ul><li><strong>Choose CFP<\/strong> when the building has 8 zones or fewer and will not grow, and you need four sounder circuits, zonal relays or a neat flush installation.<\/li><li><strong>Choose FP<\/strong> for a metal enclosure or if zones may be added later (4 to 6 or 8 to 14); see <a href=\"\/en\/sa\/media-center\/conventional-fire-alarm-panels-context-plus-fp\/\">Context Plus FP conventional panels<\/a>.<\/li><li><strong>Choose MFP<\/strong> when zones exceed 14; see <a href=\"\/en\/sa\/media-center\/context-plus-mfp-conventional-fire-alarm-panel\/\">the MFP panel<\/a>.<\/li><li>For a large building, or where the exact detector location must be shown, an addressable system fits better; see <a href=\"\/en\/sa\/media-center\/how-to-choose-fire-alarm-control-panel\/\">how to choose a fire alarm control panel<\/a>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d69cbe elementor-widget elementor-widget-text-editor\" data-id=\"3d69cbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes with CFP panels<\/h2>\n<ul><li>Choosing a CFP704 for a building that is expected to grow, then finding that CFP models cannot be expanded.<\/li><li>Connecting a mains load directly to the card relays.<\/li><li>Forgetting the CFP761 card in the main panel when adding a repeater.<\/li><li>Mixing detectors from incompatible series; see <a href=\"\/en\/sa\/media-center\/fire-alarm-spare-parts-compatibility\/\">fire alarm spare parts compatibility<\/a>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d98d474 elementor-widget elementor-widget-text-editor\" data-id=\"d98d474\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<h3>Can a CFP panel be expanded?<\/h3><p>No. All three models (2, 4 and 8 zones) are non-expandable, so fix the final zone count at the start or choose an expandable FP panel.<\/p>\n<h3>How many sounder circuits does a CFP panel have?<\/h3><p>Four conventional sounder circuits on every model.<\/p>\n<h3>How do I shut down HVAC on fire from a CFP panel?<\/h3><p>With the built-in fire relay or a CFP762 or CFP763 card inside the panel, plus an interposing relay if the load is at mains voltage.<\/p>\n<h3>Which detectors work with CFP?<\/h3><p>Context Plus Series 65A, Series 65E and ActiV conventional detectors; the difference is explained in <a href=\"\/en\/sa\/media-center\/conventional-smoke-heat-detectors-series-65a-65e-saudi\/\">Series 65A vs Series 65E detectors<\/a>.<\/p>\n<h3>Where is the datasheet?<\/h3><p>It is published on the AZEIDK site: <a href=\"\/wp-content\/uploads\/2026\/10\/context-plus-cfp-conventional-panels-datasheet.pdf\">CFP panels datasheet<\/a>.<\/p>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-112274b elementor-widget elementor-widget-text-editor\" data-id=\"112274b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>CFP is a small, fixed-size panel with features of a larger one: four sounder circuits, built-in relays, zonal relay cards and repeaters. Choose it when the building has 8 zones or fewer and will stay that way, and move to FP or MFP when you need expansion, a metal enclosure or more zones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7697d61 elementor-widget elementor-widget-text-editor\" data-id=\"7697d61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need the right conventional panel?<\/strong> Send the drawings, zone count and the systems to be interfaced, and the AZEIDK team will prepare the panel, cards and repeaters with supply, installation and testing. <a href=\"\/en\/sa\/contact\/\">Request a quote from AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Context Plus CFP conventional fire alarm panel: 2, 4 and 8 zone models, four sounder circuits, relay cards, the CFP760 repeater, and when to choose FP or MFP.<\/p>\n","protected":false},"author":0,"featured_media":33132,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-33176","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=33176"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33176\/revisions"}],"predecessor-version":[{"id":33184,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/33176\/revisions\/33184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/33132"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=33176"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=33176"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=33176"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=33176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}