{"id":30003,"date":"2026-11-27T12:19:46","date_gmt":"2026-11-27T09:19:46","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-27T12:19:47","modified_gmt":"2026-11-27T09:19:47","slug":"hitachi-vs-jianzhi-threaded-fire-fittings","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/hitachi-vs-jianzhi-threaded-fire-fittings\/","title":{"rendered":"Threaded Fittings for Fire Protection: Hitachi vs JIANZHI Malleable Iron, Thread Standards, Finish and Pressure"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"30003\" class=\"elementor elementor-30003 elementor-30002 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0660a42 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"0660a42\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0162de8 elementor-widget elementor-widget-text-editor\" data-id=\"0162de8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Threaded fittings for fire protection piping: Hitachi or JIANZHI?<\/strong> Malleable iron threaded fittings are the elbows, tees, sockets and nipples that join small-bore pipe in sprinkler branch lines and equipment connections. AZEIDK supplies two brands: Hitachi, under its Gourd Brand, and JIANZHI. This article compares them from the product pages on the AZEIDK site: material, thread standards, finish, pressure, approvals and when to choose each one.<\/p>\n<p>Both brands are part of the <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> materials AZEIDK provides through its <a href=\"\/en\/sa\/services\/technical-supply-of-fire-safety-systems\/\">technical supply service<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbfe40f elementor-widget elementor-widget-text-editor\" data-id=\"cbfe40f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>Both brands use blackheart malleable iron, in black or galvanized finish.<\/li><li>Hitachi: British, American or German threads to JIS B 2301, BS 21, ANSI B1.20.1 and DIN 2999.<\/li><li>JIANZHI: threads to EN 10226 and ISO 7-1, dimensions to EN 10242 and ISO 49, sizes from 1\/8 to 6 inches.<\/li><li>Working pressure: JIANZHI up to 25 bar (363 PSI) from -20 to 120\u00b0C; Hitachi about 300 PSI for non-shock water below 120\u00b0C.<\/li><li>The JIANZHI page lists UL and FM approvals, to be verified per fitting; the Hitachi page does not mention UL or FM approval.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-928daad elementor-widget elementor-widget-text-editor\" data-id=\"928daad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where threaded fittings are used in a fire network<\/h2>\n<p>Threaded fittings are mostly used at small sizes: sprinkler branch lines and drops, gauge and switch connections, test and drain valves, and joints around equipment that has to be removed for maintenance. Larger mains are usually joined with grooved couplings; joining methods are compared in <a href=\"\/en\/sa\/media-center\/fire-protection-piping-fittings-saudi-arabia\/\">fire protection piping and fittings<\/a>. For a threaded outlet on a grooved pipe there is the <a href=\"\/en\/sa\/media-center\/shurjoint-7721-mechanical-tee\/\">threaded-outlet mechanical tee<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d31d500 elementor-widget elementor-widget-text-editor\" data-id=\"d31d500\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Hitachi vs JIANZHI compared<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>Hitachi (Gourd Brand)<\/th><th>JIANZHI<\/th><\/tr><\/thead><tbody>\n<tr><td>Material<\/td><td>Blackheart malleable iron<\/td><td>Blackheart malleable iron to EN 1562 or ISO 5922; 350 MPa tensile strength, 10% elongation<\/td><\/tr>\n<tr><td>Thread standards<\/td><td>British, American or German: JIS B 2301, BS 21, ANSI B1.20.1, DIN 2999; taper or parallel<\/td><td>EN 10226 and ISO 7-1<\/td><\/tr>\n<tr><td>Dimension standards<\/td><td>Catalogue tables<\/td><td>EN 10242 and ISO 49<\/td><\/tr>\n<tr><td>Finish<\/td><td>Black or hot-dip galvanized (dipped in zinc before threading)<\/td><td>Black, hot-dip galvanized (about 70 \u00b5m zinc) or electrogalvanized<\/td><\/tr>\n<tr><td>Sizes<\/td><td>From 1\/8 inch, up to 10 inches in selected data<\/td><td>1\/8 to 6 inches depending on fitting type<\/td><\/tr>\n<tr><td>Pressure<\/td><td>About 300 PSI for non-shock water below 120\u00b0C, 200 PSI below 200\u00b0C, 150 PSI below 300\u00b0C<\/td><td>Up to 2.5 MPa (25 bar) from -20 to 120\u00b0C; about 2.0 MPa at 300\u00b0C<\/td><\/tr>\n<tr><td>Approvals stated<\/td><td>No UL or FM approval mentioned on the page<\/td><td>UL, FM, ISO 9001, ISO 14001; verify per fitting and size<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Figures are from the <a href=\"\/en\/sa\/products\/hitachi-malleable-iron-threaded-pipe-fittings\/\">Hitachi fittings<\/a> and <a href=\"\/en\/sa\/products\/jianzhi-malleable-iron-threaded-pipe-fittings\/\">JIANZHI fittings<\/a> pages. The final allowable pressure depends on fitting type, size, temperature and fluid.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49c8aab elementor-widget elementor-widget-text-editor\" data-id=\"49c8aab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Threads first: why the thread standard matters<\/h2>\n<p>The most costly mistake with threaded fittings is mixing thread standards. American NPT (ANSI B1.20.1) does not match British taper BSPT (ISO 7-1 or BS 21) even though the sizes look alike, and a mixed joint can feel tight yet leak under pressure. So the thread standard goes into the bill of quantities, matched to the project pipe and to the sprinkler and valve threads. Hitachi offers all three options; JIANZHI is listed with EN 10226 and ISO 7-1 threads.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ee7716 elementor-widget elementor-widget-text-editor\" data-id=\"3ee7716\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When to choose Hitachi or JIANZHI<\/h2>\n<ul><li><strong>Hitachi<\/strong> suits projects that need a specific thread standard (American, British or German) from one source, or special parts such as right- and left-hand thread sockets and ribbed sockets. See the <a href=\"\/en\/brand\/hitachi\/\">Hitachi page<\/a>.<\/li><li><strong>JIANZHI<\/strong> suits specifications that require UL Listed or FM Approved fittings, or a wide range including unions, bushings, nipples, caps and plugs in heavy, medium and light duty types. See the <a href=\"\/en\/brand\/jianzhi\/\">JIANZHI page<\/a>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edba3a4 elementor-widget elementor-widget-text-editor\" data-id=\"edba3a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes<\/h2>\n<ul><li>Using black, ungalvanized fittings in a wet or exposed location without checking the specification.<\/li><li>Ordering by size only, without the thread standard and type (taper or parallel).<\/li><li>Assuming every part from a brand is approved, instead of checking the approval of the exact part and size.<\/li><li>Over-tightening joints or using a thread sealant not suited to water networks.<\/li><\/ul>\n<p>For how fitting type affects cost without guide prices, see <a href=\"\/en\/sa\/media-center\/fire-pipes-price-cost-factors-saudi\/\">fire pipe cost factors<\/a>; for grooved fittings, see <a href=\"\/en\/sa\/media-center\/luyuan-vs-ding-liang-grooved-fittings\/\">LUYUAN vs Ding Liang grooved fittings<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-211b1a8 elementor-widget elementor-widget-text-editor\" data-id=\"211b1a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>Malleable iron vs ductile iron fittings: what is the difference?<\/h3><\/summary><p>These threaded fittings are blackheart malleable iron, while grooved fittings are usually ductile iron, as with LUYUAN.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Are galvanized fittings better for fire networks?<\/h3><\/summary><p>Galvanizing improves corrosion resistance; the choice between black and galvanized follows the project specification and installation environment.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is the maximum working pressure of JIANZHI fittings?<\/h3><\/summary><p>Up to 2.5 MPa (25 bar or 363 PSI) from -20 to 120\u00b0C per the catalogue.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Are Hitachi fittings UL listed?<\/h3><\/summary><p>The product page does not mention UL or FM approval, so ask for approval documents before ordering if the specification requires them.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9295790 elementor-widget elementor-widget-text-editor\" data-id=\"9295790\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>Start with the thread standard, then the approval the specification requires, then the finish. JIANZHI comes with stated UL and FM approvals and a wider range of parts; Hitachi offers three thread standards from one brand.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf0dc6c elementor-widget elementor-widget-text-editor\" data-id=\"cf0dc6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need threaded fittings for your project?<\/strong> Send the bill of quantities with sizes, thread standard, finish and required approval, and the AZEIDK team will prepare the offer in Hitachi or JIANZHI. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Hitachi vs JIANZHI malleable iron threaded fittings for fire piping: NPT and BSPT thread standards, black or galvanized finish, pressure ratings and UL\/FM status.<\/p>\n","protected":false},"author":0,"featured_media":29955,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-30003","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/30003","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=30003"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/30003\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29955"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=30003"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=30003"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=30003"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=30003"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}