{"id":29821,"date":"2026-11-23T16:49:58","date_gmt":"2026-11-23T13:49:58","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T16:49:59","modified_gmt":"2026-11-23T13:49:59","slug":"sffeco-fire-pumps-sfp-split-case-packages","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/sffeco-fire-pumps-sfp-split-case-packages\/","title":{"rendered":"SFFECO SFP Split Case Fire Pumps: Flows, Complete Diesel and Jockey Packages, and When to Choose Them"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29821\" class=\"elementor elementor-29821 elementor-29820 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-26a6b9b e-con-full az-el-article e-flex e-con e-parent\" data-id=\"26a6b9b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-610ca76 elementor-widget elementor-widget-text-editor\" data-id=\"610ca76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>SFFECO fire pumps<\/strong> in the SFP series are horizontal split case, single-stage centrifugal pumps with a double-suction impeller. AZEIDK&#8217;s product page lists the range from 150 to 3,500 GPM with an electric motor or diesel engine driver, and SFFECO states the series is UL Listed, FM Approved and designed to NFPA 20. AZEIDK GROUP supplies them as bare pumps or as complete skid-mounted packages.<\/p>\n<p>This article does not repeat the split case basics, which are covered in our <a href=\"\/en\/sa\/media-center\/split-case-fire-pump-saudi-en\/\">split case fire pump guide<\/a>. It focuses on the SFFECO range itself: what the maker publishes on flows, pressures and listings, what the <a href=\"\/en\/sa\/products\/sffeco-sfp-horizontal-split-case-fire-pumps\/\">SFFECO SFP split case fire pump page<\/a> and the package page show, and the questions to ask before approving a model.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ee8a9e elementor-widget elementor-widget-text-editor\" data-id=\"6ee8a9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>SFFECO SFP: horizontal split case pumps with double-suction impellers, models SFP150 to SFP3500 per AZEIDK&#8217;s product page.<\/li><li>Maximum working pressure 220 to 410 psi depending on model, per AZEIDK&#8217;s product page; SFFECO states a hydrostatic test at no less than 150% of maximum working pressure.<\/li><li>SFFECO states UL Listed and FM Approved. Listings apply to a specific model, speed and pressure range, not to the series as a whole.<\/li><li>SFFECO Certified Fire Pump Systems come on motor-driven or engine-driven skids and are performance and hydrostatically tested at the maker&#8217;s facility.<\/li><li>Spell out the controller and jockey pump in the purchase scope; do not assume they are included.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb2b492 elementor-widget elementor-widget-text-editor\" data-id=\"bb2b492\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What sets the SFFECO SFP design apart?<\/h2>\n<p>SFFECO&#8217;s official product page lists several construction details that matter to whoever runs and maintains the pump, not only to whoever approves it:<\/p>\n<ul><li><strong>Horizontally split volute casing:<\/strong> suction and discharge nozzles are cast into the lower half, so the top half lifts off to inspect the rotating assembly without disturbing piping or the driver.<\/li><li><strong>Dynamically balanced double-suction impeller:<\/strong> water enters from both sides, which balances axial forces.<\/li><li><strong>Renewable casing wear rings<\/strong> and heavy wall thickness for corrosion allowance and high pressure.<\/li><li><strong>Cartridge-type inboard and outboard bearings<\/strong> replaceable without disturbing the rotating assembly, grease lubricated with lip seals, and a fixed outboard bearing that takes end thrust.<\/li><li><strong>Rotation:<\/strong> clockwise viewed from the driver side, which must be checked against the pump room layout before suction and discharge sides are fixed.<\/li><li><strong>Standard accessories:<\/strong> suction and discharge pressure gauges with shut-off cocks.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d37a32b elementor-widget elementor-widget-text-editor\" data-id=\"d37a32b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>SFFECO fire pump flows and pressures<\/h2>\n<p>The <a href=\"\/en\/sa\/products\/sffeco-sfp-horizontal-split-case-fire-pumps\/\">AZEIDK product page<\/a> gives the following for the series, citing SFFECO&#8217;s official page and datasheet:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>Stated value<\/th><\/tr><\/thead><tbody><tr><td>Models<\/td><td>SFP150 to SFP3500<\/td><\/tr><tr><td>Rated capacity<\/td><td>150 to 3,500 GPM<\/td><\/tr><tr><td>Max working pressure<\/td><td>220 to 410 psi depending on model<\/td><\/tr><tr><td>Approx. speed<\/td><td>1,480 to 3,600 RPM<\/td><\/tr><tr><td>Suction \u00d7 discharge (in)<\/td><td>5\u00d73, 6\u00d74, 8\u00d75, 8\u00d76, 12\u00d710<\/td><\/tr><tr><td>Configuration<\/td><td>Horizontal, single-stage, double-suction impeller<\/td><\/tr><tr><td>Hydrostatic test<\/td><td>At least 150% of max working pressure<\/td><\/tr><tr><td>Driver<\/td><td>Electric motor or diesel engine<\/td><\/tr><tr><td>Model examples<\/td><td>SFP 1250-36SM-2G; 61SL5-2G and 61SL6-2G variants<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The model table on SFFECO&#8217;s own page shows the 150 GPM rows (6 in suction, 4 in discharge) and makes the role of speed clear. SFP150-25SH appears twice: at 3,500 RPM with a net pressure of 114 to 208 psi and at 3,600 RPM with 121 to 220 psi, both with a 300 psi maximum working pressure. SFP150-40SM is listed at 2,900 and 3,000 RPM with 385 psi maximum working pressure, and SFP150-SN31SH at 3,500 RPM with 226 to 316 psi net and 405 psi maximum working pressure.<\/p>\n<p>In practice, flow alone does not pick the model. The duty point (rated flow and net pressure) sets the model, speed and impeller diameter; see our <a href=\"\/en\/sa\/media-center\/fire-pump-calculation-sizing-nfpa-20\/\">NFPA 20 fire pump sizing guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-22dd1c8 elementor-widget elementor-widget-text-editor\" data-id=\"22dd1c8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>UL and FM: what SFFECO states and what you verify<\/h2>\n<p>SFFECO states the SFP pumps are UL Listed and FM Approved, and its table gives the UL-listed and FM-approved net pressure range for each model and speed. That detail is often missed: a listing is tied to model, speed and pressure range. A driver at another speed, or a duty point outside the listed range, should not be assumed to be covered.<\/p>\n<ul><li>Full model designation and speed on the datasheet, matched against UL Product iQ and the FM Approval Guide.<\/li><li>The certified performance curve at the required speed and where the duty point sits on it.<\/li><li>Saudi conformity: the SASO Technical Regulation for Fire Control Materials and Equipment requires a certificate of conformity for fire pumps through the SABER platform.<\/li><\/ul>\n<p>The step-by-step directory check is in our article on <a href=\"\/en\/sa\/media-center\/fire-pump-ul-fm-approval-check\/\">verifying UL and FM fire pump approvals<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b24218b elementor-widget elementor-widget-text-editor\" data-id=\"b24218b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Complete SFFECO packages: diesel, electric, jockey and controller<\/h2>\n<p>Beyond the bare pump, AZEIDK offers <a href=\"\/en\/sa\/products\/sffeco-certified-fire-pump-systems\/\">SFFECO certified fire pump systems<\/a>. According to SFFECO&#8217;s official package page:<\/p>\n<ul><li><strong>Skid types:<\/strong> motor driven and engine driven.<\/li><li><strong>Pump options:<\/strong> centrifugal end suction, horizontal split case or vertical turbine.<\/li><li><strong>Compliance stated:<\/strong> UL Listed, FM and NFPA.<\/li><li><strong>Testing:<\/strong> each system is performance tested before delivery and hydrostatically tested at SFFECO&#8217;s facility.<\/li><li><strong>Customisation:<\/strong> configured to project and local authority requirements.<\/li><\/ul>\n<h3>Fire pump controller<\/h3>\n<p>SFFECO&#8217;s controller page states its controllers are listed by UL to UL 218, approved by FM and built to NFPA 20 and NFPA 70, classified by full voltage or reduced voltage starting. Applications listed include electric pump, diesel pump and jockey pump control and alarm panels. Customers can choose the controller brand; otherwise the page names TORNATECH, FIRETROL, HUBBLE LEXINGTON and JOSLYN CLARKE. Starting-method selection is covered in our <a href=\"\/en\/sa\/media-center\/fire-pump-controller-selection\/\">fire pump controller guide<\/a>.<\/p>\n<h3>Jockey pump<\/h3>\n<p>SFFECO describes the jockey pump as a small motor-driven pump that makes up minor leakage and holds standby pressure, reducing main pump starts. A pressure switch starts it below a set pressure; its controller is across-the-line with a Hand-Off-Automatic selector and an optional minimum run timer of at least 3 minutes. No capacities are published, so size it from the project calculation as in our <a href=\"\/en\/sa\/media-center\/jockey-pump-sizing-pressure-settings\/\">jockey pump sizing article<\/a>.<\/p>\n<h3>Electric or diesel?<\/h3>\n<p>SFP pumps run with either driver. SFFECO notes a speed tolerance of \u00b14% from rated speed, so a 3,000 RPM pump can run with a 2,900 RPM driver. The driver choice itself depends on site power reliability and the designer&#8217;s and consultant&#8217;s requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04654b8 elementor-widget elementor-widget-text-editor\" data-id=\"04654b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When does an SFFECO split case pump make sense?<\/h2>\n<ul><li>Relatively high flow, such as sprinkler and hose networks in malls, hospitals, warehouses and factories.<\/li><li>Positive suction from a tank or main, not a deep well (wells need a vertical turbine pump).<\/li><li>A pump room long enough for a horizontal pump and driver, with clearance to lift the top casing half.<\/li><li>A specification calling for UL-listed or FM-approved pumps, with the selected model covering the duty point within its listed range.<\/li><\/ul>\n<p>For small flows and tight rooms an end suction pump may be enough. For all types, see <a href=\"\/en\/sa\/media-center\/fire-pump-types-selection-saudi\/\">fire pump types and NFPA 20 basics<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b20209 elementor-widget elementor-widget-text-editor\" data-id=\"6b20209\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Questions to ask before approving an SFFECO package<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Question<\/th><th>Why it matters<\/th><\/tr><\/thead><tbody><tr><td>Full model, speed and impeller diameter?<\/td><td>Listing and curve depend on all three<\/td><\/tr><tr><td>Is the duty point inside the listed net pressure range?<\/td><td>A point outside the range is not covered<\/td><\/tr><tr><td>Electric or diesel, and is there a standby pump?<\/td><td>Drives the controller, fuel tank and room ventilation<\/td><\/tr><tr><td>Are the controller, jockey pump and jockey controller in scope?<\/td><td>The package page does not itemise components, so write them into the quote<\/td><\/tr><tr><td>Suction and discharge sizes?<\/td><td>Sets valve, pipe and connection sizes in the room<\/td><\/tr><tr><td>SABER certificate of conformity for the model?<\/td><td>Required for fire pumps under the SASO regulation<\/td><\/tr><tr><td>Factory test documents?<\/td><td>Compared later with site acceptance test results<\/td><\/tr><\/tbody><\/table><\/div>\n<p>AZEIDK supplies fire pumps from SFFECO, WATEX and Jack Pump. When a project specification calls for another brand, AZEIDK&#8217;s supply team works on sourcing it to the required specification and approvals. See the other series in our <a href=\"\/en\/sa\/products\/?product_category=fire-pumps\">fire pumps category<\/a> and our <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems solutions<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-611d231 elementor-widget elementor-widget-text-editor\" data-id=\"611d231\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common ordering mistakes<\/h2>\n<ul><li><strong>Ordering by flow only:<\/strong> &#8220;a 1,000 GPM pump&#8221; with no net pressure produces a quote for a model that misses the duty point.<\/li><li><strong>Assuming the UL mark covers any speed:<\/strong> SFFECO&#8217;s own table shows different pressure ranges for one model at two speeds.<\/li><li><strong>Ignoring rotation:<\/strong> check it against suction and discharge routing on the shop drawing before casting the plinth.<\/li><li><strong>Leaving out support items:<\/strong> jockey pump and controller, pressure switches, test meter and relief valve belong as separate BOQ lines.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3be4c66 elementor-widget elementor-widget-text-editor\" data-id=\"3be4c66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>FAQ<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the largest SFFECO SFP pump?<\/h3><\/summary><p>AZEIDK&#8217;s page lists the series from SFP150 to SFP3500, that is 150 to 3,500 GPM. The model is chosen from the duty point, not the top of the range.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Are SFFECO fire pumps UL and FM approved?<\/h3><\/summary><p>SFFECO states the SFP series is UL Listed and FM Approved. Verify the exact model, speed and pressure range in each body&#8217;s official directory before approval.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Does an SFFECO package include the jockey pump and controller?<\/h3><\/summary><p>SFFECO publishes separate pages for controllers and jockey pumps, but the package page does not itemise contents, so state the scope explicitly in the request for quotation.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can an SFFECO split case pump run on diesel?<\/h3><\/summary><p>Yes. SFFECO states the series runs with an electric motor or diesel engine, and its packages come on motor-driven or engine-driven skids.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Bare SFP pump or certified package: what is the difference?<\/h3><\/summary><p>The bare pump is the pumping unit only. The package is skid mounted with its driver, can use an end suction, split case or vertical turbine pump, and is tested at the factory before delivery.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What is the hydrostatic test pressure for SFFECO SFP pumps?<\/h3><\/summary><p>SFFECO states at least 150% of maximum working pressure. A model with a 300 psi maximum working pressure is therefore tested at 450 psi or more.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cbcc78 elementor-widget elementor-widget-text-editor\" data-id=\"1cbcc78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>SFFECO SFP pumps cover a wide flow range in a design that is easy to service, and the maker&#8217;s UL and FM statements are a good starting point. A sound approval still takes three steps: a calculated duty point, a model and speed inside the listed range, and a written scope that names the driver, the controller and the jockey pump.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e05ce8 elementor-widget elementor-widget-text-editor\" data-id=\"0e05ce8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing a pump room BOQ?<\/strong> Send us the required flow and pressure, water source and driver type, and we will return a proposed SFFECO model with datasheet, performance curve and listing status. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK GROUP team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ca8dc0 elementor-widget elementor-widget-text-editor\" data-id=\"0ca8dc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/sffecoglobal.com\/sffeco-product\/centrifugal-horizontal-split-case-fire-pumps\/\" rel=\"noopener\" target=\"_blank\">Centrifugal Horizontal Split Case Fire Pumps<\/a> (SFFECO), <a href=\"https:\/\/sffecoglobal.com\/sffeco-product\/certified-fire-pump-systems\/\" rel=\"noopener\" target=\"_blank\">Certified Fire Pump Systems<\/a> (SFFECO), <a href=\"https:\/\/sffecoglobal.com\/?p=4624\" rel=\"noopener\" target=\"_blank\">Fire Pump Controllers<\/a> (SFFECO), <a href=\"https:\/\/sffecoglobal.com\/?p=4628\" rel=\"noopener\" target=\"_blank\">Jockey Pumps<\/a> (SFFECO), and AZEIDK&#8217;s product pages for the SFP series and SFFECO certified fire pump systems.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>SFFECO fire pumps, SFP split case series: models, pressures, UL and FM listing by model and speed, and diesel or electric packages with jockey and controller.<\/p>\n","protected":false},"author":0,"featured_media":29430,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-29821","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29821"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29821\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29430"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29821"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29821"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29821"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}