{"id":29815,"date":"2026-11-23T16:49:37","date_gmt":"2026-11-23T13:49:37","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T16:49:38","modified_gmt":"2026-11-23T13:49:38","slug":"victaulic-sprinkler-head-installation","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/victaulic-sprinkler-head-installation\/","title":{"rendered":"Victaulic Sprinkler Installation: The Right Wrench, Torque Limits, Thread Sealant and the Mistakes That Fail Acceptance"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29815\" class=\"elementor elementor-29815 elementor-29814 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-da78642 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"da78642\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e2ae6a elementor-widget elementor-widget-text-editor\" data-id=\"1e2ae6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Victaulic sprinkler installation<\/strong> follows the official FireLock Installation and Maintenance Instructions I-40: use the model&#8217;s own sprinkler wrench on the wrench boss only, apply two to three wraps of PTFE tape to the male threads only, stay within the maximum torque (19 N\u00b7m for 1\/2-inch NPT, 27 N\u00b7m for 3\/4-inch NPT), and leave the bulb protector on until just before the system goes into service.<\/p>\n<p>This article walks through those steps for the Victaulic FireLock models AZEIDK GROUP lists in Saudi Arabia: the V27 sprinklers V2703, V2704 and V2707, the K11.2 storage sprinklers V3403 and V3407, the V4702 ESFR, and the FL-QR\/SW horizontal sidewall range. The focus is on the details a consultant or owner checks at handover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4129784 elementor-widget elementor-widget-text-editor\" data-id=\"4129784\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key Takeaways<\/h2><ul><li>The reference is Victaulic I-40, Installation and Maintenance Instructions for FireLock Automatic Sprinklers (REV Y, updated 04\/2024), read together with each model&#8217;s datasheet.<\/li><li>Each family has its own wrench: V27 for V27 sprinklers and the V2710 sidewall, V34 for V3403, V3407 and V3410, V44\/V47 for the V4702, and V56 for the V2826 and V4226 sidewalls.<\/li><li>Maximum assembly torque in I-40: 14 ft-lbs (19 N\u00b7m) for 1\/2-inch NPT and 20 ft-lbs (27 N\u00b7m) for 3\/4-inch NPT.<\/li><li>Never install a sprinkler that was dropped or struck, even if it looks undamaged, and never paint or coat a sprinkler on site.<\/li><li>Bulb protectors are removed by hand, without tools, before the system is placed in service; the sprinkler cannot operate properly with the protector on.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89ea315 elementor-widget elementor-widget-text-editor\" data-id=\"89ea315\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which Official Document Governs Victaulic Sprinkler Installation?<\/h2>\n<p>Victaulic publishes a single installation and maintenance manual for its FireLock automatic sprinklers, I-40. It covers storage and handling, thread sealant, torque, the wrench table, bulb protectors, escutcheon hole sizes, painting and replacement.<\/p>\n<p>The manual does not replace the datasheet. Approved temperature ratings, deflector-to-ceiling distances, the approved escutcheon and UL\/FM status all vary by model and configuration. Start from the product page: <a href=\"\/en\/sa\/products\/victaulic-firelock-v27-k5-6-fire-sprinklers-v2703-v2704-v2707-and-v2708\/\">Victaulic FireLock V27 K5.6 sprinklers<\/a>, <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-sr-st-k11-2-storage-sprinklers-v3403-and-v3407\/\">FL-SR\/ST K11.2 storage sprinklers V3403 and V3407<\/a>, <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-qr-st-esfr-k16-8-pendent-storage-sprinkler-v4702\/\">V4702 ESFR pendent<\/a> and <a href=\"\/en\/sa\/products\/victaulic-firelock-fl-qr-sw-horizontal-sidewall-sprinklers-v2826-v4226-v2710-and-v3410\/\">FL-QR\/SW horizontal sidewall sprinklers<\/a>.<\/p>\n<p>I-40 requires FireLock sprinklers to be used in systems designed and installed to NFPA 13 or equivalent, FM or VdS standards where they apply, and local building and fire codes. In Saudi Arabia that means the Saudi Fire Protection Code SBC 801 and the approved project documents. Installers should be trained and experienced.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c8c828 elementor-widget elementor-widget-text-editor\" data-id=\"4c8c828\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Before Installation: Receiving, Storage and Handling<\/h2>\n<p>Most sprinkler rejections on site start before the sprinkler reaches the pipe. I-40 requires the following:<\/p>\n<ul><li>Store sprinklers in a cool, dry place in the original packaging; do not empty them into bags or buckets.<\/li><li>Do not handle a sprinkler by its deflector.<\/li><li>Do not install any sprinkler that has been dropped or struck by another object, even if it shows no damage.<\/li><li>Do not install a glass-bulb sprinkler with a cracked bulb or fluid loss; discard damaged or corroded sprinklers.<\/li><li>Verify model, orifice (K-factor) and temperature rating before installation.<\/li><\/ul>\n<p>Install each sprinkler only in its intended orientation. The V3403 is upright and the V3407 is pendent, even though both are K11.2.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fa437a elementor-widget elementor-widget-text-editor\" data-id=\"8fa437a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which Sprinkler Wrench Fits Each Model?<\/h2>\n<p>Victaulic sprinklers are not installed with an adjustable or pipe wrench. I-40 assigns each family a wrench that engages the wrench boss without loading the frame, deflector or bulb. For the models on the AZEIDK site:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Model<\/th><th>Type<\/th><th>Open-end wrench<\/th><th>Recessed wrench<\/th><\/tr><\/thead><tbody><tr><td>V2703 \/ V2704<\/td><td>Upright K5.6<\/td><td>V27 (ST01000000)<\/td><td>Not applicable<\/td><\/tr><tr><td>V2707<\/td><td>Pendent or recessed pendent K5.6<\/td><td>V27 (ST01000000)<\/td><td>V27-2 (ST12000002)<\/td><\/tr><tr><td>V3403<\/td><td>Upright storage K11.2<\/td><td>V34 (ST02000000)<\/td><td>Not applicable<\/td><\/tr><tr><td>V3407<\/td><td>Pendent storage K11.2<\/td><td>V34 (ST02000000)<\/td><td>V34 Recessed (ST22000000)<\/td><\/tr><tr><td>V4702<\/td><td>ESFR pendent K16.8<\/td><td>V44\/V47 (ST92000800)<\/td><td>Not applicable<\/td><\/tr><tr><td>V2826 \/ V4226<\/td><td>Horizontal sidewall K2.8 \/ K4.2<\/td><td>V56 (S325390000)<\/td><td>V56-2 (S325391000)<\/td><\/tr><tr><td>V2710<\/td><td>Horizontal sidewall K5.6<\/td><td>V27 (ST01000000)<\/td><td>V27-2 (ST12000002)<\/td><\/tr><tr><td>V3410<\/td><td>Horizontal sidewall K8.0<\/td><td>V34 (ST02000000)<\/td><td>V34 Recessed (ST22000000)<\/td><\/tr><\/tbody><\/table><\/div>\n<p>For models supplied with an IGS grooved inlet instead of a thread, the connection is made with the Style V9 coupling and its 3\/16-inch hex bit (J000V09000), following the V9 instructions. For grooved joints in general, see <a href=\"\/en\/sa\/media-center\/grooved-coupling-installation-roll-grooving\/\">grooved coupling installation<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47c89d7 elementor-widget elementor-widget-text-editor\" data-id=\"47c89d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Thread Sealant and Torque for Victaulic Sprinkler Installation<\/h2>\n<h3>How much PTFE tape goes on a sprinkler thread?<\/h3>\n<p>I-40 calls for two to three wraps of tape or a non-hardening pipe-joint compound on the male threads only. Sealant must not enter the orifice or touch the bulb or seal. Nothing goes on the fitting&#8217;s female thread, and any loose tape is trimmed before make-up.<\/p>\n<h3>What is the maximum torque for Victaulic sprinklers?<\/h3>\n<p>Thread the sprinkler in by hand, then finish with the correct wrench. I-40 sets these maximum assembly torques:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Thread (NPT)<\/th><th>Maximum torque<\/th><th>AZEIDK models with this thread<\/th><\/tr><\/thead><tbody><tr><td>1\/2-inch<\/td><td>14 ft-lbs \/ 19 N\u00b7m<\/td><td>V2703, V2704, V2707, V2826, V4226, V2710<\/td><\/tr><tr><td>3\/4-inch<\/td><td>20 ft-lbs \/ 27 N\u00b7m<\/td><td>V3403, V3407, V3410, V4702<\/td><\/tr><tr><td>1-inch<\/td><td>30 ft-lbs \/ 41 N\u00b7m<\/td><td>None of the listed models<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The instruction is to tighten securely enough to prevent leakage without exceeding these values. The table is written for NPT; for BSPT versions (15 or 20 mm) check the model datasheet. Over-torque distorts the frame or stresses the bulb; under-torque shows up as a leak during the hydrostatic test. For leak causes after commissioning, see <a href=\"\/en\/sa\/media-center\/fire-sprinkler-leak-accidental-discharge\/\">fire sprinkler leaks<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f0d161 elementor-widget elementor-widget-text-editor\" data-id=\"8f0d161\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation Steps in Order<\/h2>\n<ol><li>Depressurize and fully drain the piping, including any isolated branch or section, before installing, removing or adjusting.<\/li><li>Inspect the sprinkler: no cracked bulb, no fluid loss, no bent frame or deflector.<\/li><li>Recessed models: install the recess collar and tighten it fully against the wrench boss.<\/li><li>Apply sealant to the male threads only.<\/li><li>Hand-thread in the correct orientation, then tighten with the designated wrench on the wrench boss, within the maximum torque.<\/li><li>Recessed models: center the escutcheon and push it onto the collar until it contacts the ceiling or wall.<\/li><li>Where required, install the sprinkler guard after the sprinkler is installed and before the system is tested.<\/li><\/ol>\n<h3>What changes for horizontal sidewall sprinklers?<\/h3>\n<p>The FL-QR\/SW product page requires horizontal installation only, with the waterway axis perpendicular to the wall and the word TOP on the deflector facing up. The deflector-to-ceiling distance comes from the model&#8217;s approval table. For selection, see <a href=\"\/en\/sa\/media-center\/sidewall-sprinkler-victaulic-fl-qr-sw\/\">Victaulic sidewall sprinklers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ef3236 elementor-widget elementor-widget-text-editor\" data-id=\"7ef3236\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When Should the Bulb Protector Be Removed?<\/h2>\n<p>FireLock sprinklers ship with plastic bulb protectors. I-40 states that sprinklers cannot operate properly with protectors installed, so they must be removed from all sprinklers before the system is placed in service, carefully by hand and never with tools on glass-bulb sprinklers.<\/p>\n<p>The manual allows removal immediately after installation for all upright sprinklers and for any sprinkler more than 10 ft (3 m) above the floor. Lower pendent and sidewall sprinklers keep their protectors through ceiling and finishing work, followed by a dedicated removal round before commissioning. This item belongs on the snag list before handover.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b75b0a elementor-widget elementor-widget-text-editor\" data-id=\"4b75b0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Escutcheons, Ceiling Holes and Guards<\/h2>\n<p>A recessed or concealed sprinkler and its escutcheon are not chosen separately. As quoted in the QRFS references below, NFPA 13 (2022) requires escutcheons used with recessed, flush-type or concealed sprinklers to be part of a listed sprinkler assembly. NFPA 25 (2023) requires a missing listed escutcheon on these sprinklers to be replaced with the listed part, and the sprinkler to be replaced if that part is no longer available.<\/p>\n<p>I-40 also gives ceiling hole sizes per escutcheon style. For semi-recessed escutcheons the hole is 51 mm minimum and 60 mm maximum, matching the V27 product page for the recessed V2707 (51 to 60 mm hole, escutcheon about 75 mm in diameter). A larger hole leaves a gap around the sprinkler; a smaller one stops the escutcheon from seating.<\/p>\n<p>Guards go on after the sprinkler is seated and before testing: engage the guard tabs in the recess between the wrench boss and the threads, then tighten the two screws evenly without damaging the frame, deflector or bulb. For guard and escutcheon types, see <a href=\"\/en\/sa\/media-center\/sprinkler-head-guards-escutcheons\/\">sprinkler head guards and escutcheons<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73b3ea4 elementor-widget elementor-widget-text-editor\" data-id=\"73b3ea4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why Victaulic Sprinklers Must Not Be Painted or Cleaned with Chemicals<\/h2>\n<p>I-40 is explicit: do not paint, coat, plate or alter sprinklers. It states that alterations, including painting and coating, void the Victaulic warranty and impact system integrity. Protect sprinklers before ceilings are painted. If the project needs a colored finish, order a factory finish such as white or black polyester from the model&#8217;s options.<\/p>\n<p>Do not clean sprinklers with soapy water, detergents, ammonia or other chemicals; remove dust with a soft, dry cloth. Do not hang or attach anything to a sprinkler, and do not test sprinklers with a heat source.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1468b0 elementor-widget elementor-widget-text-editor\" data-id=\"d1468b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Installation Mistakes That Fail Acceptance<\/h2>\n<ul><li>Sprinklers installed with a pipe or adjustable wrench, leaving marks on the frame or deflector.<\/li><li>PTFE tape visible inside the orifice, or compound on the bulb.<\/li><li>Leaks at the hydrostatic test from under-torque, or a distorted frame from over-torque.<\/li><li>Upright sprinklers installed pendent or vice versa, or a sidewall with TOP facing down.<\/li><li>An escutcheon that does not match the model, or a ceiling hole outside the specified range.<\/li><li>Bulb protectors left on after commissioning.<\/li><li>Paint or overspray on sprinklers from finishing work.<\/li><li>Temperature rating or K-factor different from the approved drawings, especially in storage and ESFR areas.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0c3a25 elementor-widget elementor-widget-text-editor\" data-id=\"d0c3a25\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pre-Acceptance Checklist<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>What to check<\/th><th>Reference<\/th><\/tr><\/thead><tbody><tr><td>Match<\/td><td>Model, K-factor, temperature, response and finish as per drawings and submittal<\/td><td>Approved drawings and datasheet<\/td><\/tr><tr><td>Condition<\/td><td>No cracked bulbs, distortion, corrosion or paint<\/td><td>I-40<\/td><\/tr><tr><td>Orientation<\/td><td>Upright, pendent or sidewall as designed; TOP up on sidewalls<\/td><td>I-40 and datasheet<\/td><\/tr><tr><td>Escutcheon<\/td><td>Listed escutcheon for the model, in contact with ceiling or wall<\/td><td>Datasheet and NFPA 13<\/td><\/tr><tr><td>Protectors<\/td><td>Removed from every sprinkler before service<\/td><td>I-40<\/td><\/tr><tr><td>Leakage<\/td><td>No leaks at joints after testing<\/td><td>NFPA 13 and the AHJ<\/td><\/tr><\/tbody><\/table><\/div>\n<p>I-40 also reminds installers that the whole system is tested after installation per NFPA 13, NFPA 25 or equivalent and the authority having jurisdiction, and that a successful test does not replace correct installation and maintenance. For flushing, hydrostatic and main drain tests, see <a href=\"\/en\/sa\/media-center\/sprinkler-system-acceptance-tests-flushing-main-drain\/\">sprinkler system acceptance tests<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64f5b67 elementor-widget elementor-widget-text-editor\" data-id=\"64f5b67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Replacing a Victaulic Sprinkler After Operation or Damage<\/h2>\n<p>An operated sprinkler is never reassembled or reused. Replace it with a new sprinkler of the same type, orifice, temperature rating and response. Replacement starts by taking the system out of service and notifying the AHJ, then relieving pressure, removing the sprinkler with the correct wrench, installing the new one with the same steps and checking for leaks. After a fire, inspect the whole system and replace sprinklers exposed to corrosive products or high temperatures.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3092669 elementor-widget elementor-widget-text-editor\" data-id=\"3092669\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Victaulic FireLock Sprinklers from AZEIDK GROUP<\/h2>\n<p>AZEIDK GROUP supplies the Victaulic FireLock sprinklers listed on its Saudi product pages as part of its <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>, with the datasheet and installation instructions for each model, and provides <a href=\"\/en\/sa\/services\/testing-commissioning-handover\/\">testing, commissioning and handover<\/a>. Before final approval, check the latest Victaulic documents for the required configuration and its approval status. For details of the V27 models and their response types, see <a href=\"\/en\/sa\/media-center\/victaulic-v27-quick-response-sprinkler\/\">Victaulic V27 sprinklers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6b5fc0 elementor-widget elementor-widget-text-editor\" data-id=\"a6b5fc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently Asked Questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What torque should a 1\/2-inch sprinkler be tightened to?<\/h3><\/summary><p>Victaulic I-40 sets a maximum of 14 ft-lbs (19 N\u00b7m) for FireLock sprinklers with 1\/2-inch NPT threads. Tighten enough to prevent leakage without exceeding that value.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can PTFE tape be used on sprinkler threads?<\/h3><\/summary><p>Yes. I-40 allows two to three wraps of tape or a non-hardening pipe-joint compound on the male threads only, kept away from the orifice and bulb.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can a Victaulic sprinkler be installed with a pipe wrench?<\/h3><\/summary><p>No. Each family has a designated wrench, such as V27, V34 or V56, that engages the wrench boss without loading the frame, deflector or bulb.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When should the plastic bulb protector be removed?<\/h3><\/summary><p>Before the system is placed in service, by hand and without tools. It may be removed right after installation on upright sprinklers or on any sprinkler more than 3 m above the floor.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can sprinklers be painted with the ceiling?<\/h3><\/summary><p>No. Victaulic prohibits painting, coating or altering sprinklers; it voids the warranty and impacts system integrity. Order the required color as a factory finish.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can I install a sprinkler that was dropped but looks fine?<\/h3><\/summary><p>No. I-40 says not to install any sprinkler that has been dropped or struck, even if it does not appear damaged.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-507c4dc elementor-widget elementor-widget-text-editor\" data-id=\"507c4dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Installing a Victaulic sprinkler takes minutes, but the details are specific: the right wrench for the model, sealant on the male thread only, torque within the limit, correct orientation, a listed escutcheon and protectors removed at the right time. Checking these during installation costs far less than removing and reinstalling sprinklers after handover comments.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8892936 elementor-widget elementor-widget-text-editor\" data-id=\"8892936\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing to install Victaulic sprinklers on your project?<\/strong> Send us the models, quantities and approved drawings, and we will supply the sprinklers with the datasheets, installation instructions and the correct wrench for each model. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK GROUP team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3f7749 elementor-widget elementor-widget-text-editor\" data-id=\"c3f7749\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>Sources:<\/strong> <a href=\"https:\/\/assets.victaulic.com\/assets\/uploads\/literature\/I-40.pdf\" rel=\"noopener\" target=\"_blank\">Installation and Maintenance Instructions I-40, FireLock Automatic Sprinklers<\/a> (Victaulic, REV Y, 04\/2024), <a href=\"https:\/\/assets.victaulic.com\/assets\/uploads\/literature\/I-40_ESC.pdf\" rel=\"noopener\" target=\"_blank\">I-40.ESC FireLock Dry Sprinkler Sleeve and Skirt, Flush Plate, and Recessed Escutcheon Options<\/a> (Victaulic), <a href=\"https:\/\/blog.qrfs.com\/462-flush-vs-flush-sprinkler-escutcheons-what-must-be-listed\/\" rel=\"noopener\" target=\"_blank\">Flush vs Flush Sprinkler Escutcheons: What Must Be Listed?<\/a> (QRFS, quoting NFPA 13-2022), <a href=\"https:\/\/blog.qrfs.com\/424-missing-fire-sprinkler-escutcheons-the-real-impacts-on-performance\/\" rel=\"noopener\" target=\"_blank\">Missing Fire Sprinkler Escutcheons: The Real Impacts on Performance<\/a> (QRFS, quoting NFPA 25-2023), and the Victaulic FireLock product pages on the AZEIDK GROUP website<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Victaulic sprinkler installation per the official I-40 manual: the right wrench per model, PTFE tape, maximum torque, bulb protectors and acceptance checks.<\/p>\n","protected":false},"author":0,"featured_media":29429,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,329,322],"tags":[],"azeidk_region":[223],"class_list":["post-29815","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-operation-maintenance-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29815"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29815\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29429"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29815"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29815"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29815"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}