{"id":29794,"date":"2026-11-23T16:14:32","date_gmt":"2026-11-23T13:14:32","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T16:14:32","modified_gmt":"2026-11-23T13:14:32","slug":"fire-extinguisher-maintenance-contract-template","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-extinguisher-maintenance-contract-template\/","title":{"rendered":"Fire Extinguisher Maintenance Contract in Saudi Arabia: Clauses, Monthly and Annual Inspection Schedule, and Owner and Contractor Responsibilities"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29794\" class=\"elementor elementor-29794 elementor-29793 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a3439d4 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"a3439d4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99b1aa9 elementor-widget elementor-widget-text-editor\" data-id=\"99b1aa9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A good <strong>fire extinguisher maintenance contract<\/strong> names the number, type and location of every extinguisher, who does the monthly inspection, when annual maintenance, six-year maintenance and hydrostatic testing fall due, who supplies a temporary unit while one is out for recharge, and which report the owner receives after each visit. Without these clauses the contract is only a document shown at inspection time.<\/p>\n<p>This article is written for building owners and facility managers. It sets out the clauses to include, the inspection schedule as given in NFPA 10, and how responsibilities split between owner and contractor. It is a negotiation checklist, not a legal template. If you want the work done, extinguisher maintenance by AZEIDK GROUP&#8217;s own team is part of our <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance contracts<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8570c1a elementor-widget elementor-widget-text-editor\" data-id=\"8570c1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>NFPA 10 sets three levels of care: a monthly visual inspection, annual maintenance by a trained technician, and longer-cycle work such as six-year internal examination and hydrostatic testing every 5 or 12 years depending on type.<\/li><li>Monthly inspections can be done by the owner&#8217;s trained staff. Annual maintenance, recharging and testing need a trained technician with proper tools, parts and the manufacturer&#8217;s service manual.<\/li><li>When an extinguisher is removed for recharge or testing, a replacement suitable for the hazard and of at least equal rating must be provided. Write this into the contract.<\/li><li>The extinguisher contract belongs with the fire and life safety systems contract and stays separate from the low current and CCTV contract.<\/li><li>Records and tags belong to the owner and must be handed over up to date, because they are what inspectors and licence renewals look at.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b467556 elementor-widget elementor-widget-text-editor\" data-id=\"b467556\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why extinguishers need their own clauses<\/h2>\n<p>Most fire system maintenance contracts are built around fixed systems: the alarm panel, the fire pump, the sprinklers. Extinguishers often get a single line such as &#8220;extinguisher maintenance as required&#8221;. Extinguishers differ from fixed systems in three ways that matter for the contract:<\/p>\n<ul><li><strong>Quantity and variety:<\/strong> a mid-size building can hold dozens of dry powder, CO2, foam and wet chemical units, each with its own test cycle.<\/li><li><strong>Time out of service:<\/strong> recharging and hydrostatic testing mean taking the unit off the wall, leaving an empty bracket unless a replacement is agreed.<\/li><li><strong>Consumption:<\/strong> an extinguisher used on a small fire or discharged by tampering needs recharging straight away, outside the visit schedule.<\/li><\/ul>\n<p>So the contract needs an extinguisher annex, even inside a wider fire systems agreement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5223e56 elementor-widget elementor-widget-text-editor\" data-id=\"5223e56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fire extinguisher maintenance contract: monthly and annual schedule<\/h2>\n<p>NFPA 10 is the usual technical reference for portable extinguisher inspection and maintenance. The edition that applies to your facility is set by the Saudi Fire Protection Code (SBC 801) and Civil Defense requirements. The intervals below are as stated in the standard and apply together with the manufacturer&#8217;s instructions:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Task<\/th><th>Interval<\/th><th>Usually done by<\/th><th>What the contract should say<\/th><\/tr><\/thead><tbody><tr><td>Visual inspection (location, access, gauge, seal and pin, damage, corrosion)<\/td><td>Monthly<\/td><td>Owner&#8217;s trained staff or contractor&#8217;s technician<\/td><td>Who is responsible and how it is recorded (tag or electronic log)<\/td><\/tr><tr><td>Annual maintenance (mechanical parts, agent, expellant; new seal and maintenance tag)<\/td><td>Annually, or sooner if monthly checks show a need<\/td><td>Trained technician<\/td><td>Visit date and a per-unit report format<\/td><\/tr><tr><td>Internal examination of stored-pressure dry chemical units on a 12-year hydro cycle<\/td><td>Every 6 years<\/td><td>Trained technician<\/td><td>List of units due each year and pricing basis<\/td><\/tr><tr><td>Internal examination of CO2 and wet chemical units<\/td><td>Every 5 years<\/td><td>Trained technician<\/td><td>Tie to the hydrostatic test date<\/td><\/tr><tr><td>Hydrostatic test: water, CO2, wet chemical, foam, stainless steel dry chemical<\/td><td>Every 5 years<\/td><td>Facility with special equipment and training<\/td><td>Who does it, where, and who covers transport and replacement units<\/td><\/tr><tr><td>Hydrostatic test: mild steel or aluminium dry chemical, halon<\/td><td>Every 12 years<\/td><td>Facility with special equipment and training<\/td><td>As above<\/td><\/tr><tr><td>Non-rechargeable units<\/td><td>Removed from service 12 years after manufacture<\/td><td>Contractor flags them, owner approves replacement<\/td><td>Advance notice and replacement quote<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The six-year clock restarts when a unit is recharged or hydrostatically tested. That is why the contract needs an inventory holding each unit&#8217;s manufacture date, last recharge and last test, not just the visit date. To read this data on the cylinder, see our guide to the <a href=\"\/en\/sa\/media-center\/fire-extinguisher-label-inspection-tag\/\">fire extinguisher label and inspection tag<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79e632b elementor-widget elementor-widget-text-editor\" data-id=\"79e632b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Owner and contractor responsibilities<\/h2>\n<p>Most maintenance disputes come from a task nobody owned. The split below is a starting point; adjust it to your facility size and safety staff:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Task<\/th><th>Owner \/ facility manager<\/th><th>Maintenance contractor<\/th><\/tr><\/thead><tbody><tr><td>Initial inventory and location plan<\/td><td>Provides drawings and access<\/td><td>Verifies on site and builds the inventory<\/td><\/tr><tr><td>Monthly inspection<\/td><td>Trained staff, if agreed<\/td><td>Does it during visits if in scope, and trains owner&#8217;s staff<\/td><\/tr><tr><td>Annual maintenance, recharge, internal examination<\/td><td>Approves the report<\/td><td>Performs it with a trained technician and suitable parts<\/td><\/tr><tr><td>Hydrostatic testing<\/td><td>Approves the due list and cost<\/td><td>Coordinates testing at an equipped facility and records the result<\/td><\/tr><tr><td>Temporary replacement<\/td><td>Provides safe temporary storage<\/td><td>Supplies a unit of the same type and at least equal rating<\/td><\/tr><tr><td>Reporting a used or missing unit<\/td><td>Reports within the agreed time<\/td><td>Responds within the agreed response time<\/td><\/tr><tr><td>Records<\/td><td>Keeps the master copy<\/td><td>Hands over updated records after each visit<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4e4060 elementor-widget elementor-widget-text-editor\" data-id=\"f4e4060\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Contract clause checklist<\/h2>\n<p>Use this list to review any contractor&#8217;s draft. Clauses follow the order they usually take in a service contract:<\/p>\n<ol>\n<li><strong>Parties and site:<\/strong> facility name, address, activity type, and buildings or floors covered.<\/li>\n<li><strong>Inventory annex:<\/strong> each unit&#8217;s serial or asset number, type, capacity, location, manufacture date, last recharge and last hydrostatic test, updated with every addition or replacement.<\/li>\n<li><strong>Scope:<\/strong> whether monthly inspections are included or visits cover periodic maintenance only; number and timing of visits, including out-of-hours visits.<\/li>\n<li><strong>Annual maintenance:<\/strong> NFPA 10 and the manufacturer&#8217;s instructions as the procedure reference, with a new seal and a maintenance tag showing month, year, technician and company.<\/li>\n<li><strong>Long-cycle work:<\/strong> are six-year maintenance and hydrostatic testing in the contract price or priced per unit? Who performs the test and where? State it plainly, because testing needs special equipment and training.<\/li>\n<li><strong>Recharge after use:<\/strong> response time for recharge requests, and whether emergency recharges are included or charged separately.<\/li>\n<li><strong>Temporary replacement:<\/strong> the contractor places a unit of the same type and at least equal rating for the whole time a unit is away.<\/li>\n<li><strong>Agents and parts:<\/strong> as specified by the manufacturer for that unit; new replacement extinguishers must conform to the SASO Technical Regulation for Fire Control Materials and Equipment.<\/li>\n<li><strong>Replacement:<\/strong> when the contractor recommends replacement (failed test, damaged cylinder, non-rechargeable unit at end of life), with a written quote before any replacement.<\/li>\n<li><strong>Response time:<\/strong> for routine and urgent requests, and the agreed reporting channel. See our guide to <a href=\"\/en\/sa\/media-center\/sla-fire-system-maintenance-contract-response-time\/\">SLAs and response times<\/a>.<\/li>\n<li><strong>Reports and records:<\/strong> a report after every visit listing each unit&#8217;s condition, action taken and remarks, an updated maintenance log, and tag photos on request.<\/li>\n<li><strong>Exclusions:<\/strong> what is not covered, such as units damaged by misuse or new units for an extension.<\/li>\n<li><strong>Term, renewal and handover:<\/strong> contract term and renewal, and the contractor&#8217;s duty to hand over complete records to the owner or the next contractor at the end.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73b4310 elementor-widget elementor-widget-text-editor\" data-id=\"73b4310\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Tags and records: proof the work was done<\/h2>\n<p>An inspector does not see the visit, only its traces on the unit and in the log. NFPA 10 sets clear markings for each level:<\/p>\n<ul><li><strong>Monthly inspection:<\/strong> date and inspector&#8217;s initials on a tag, checklist or electronic record.<\/li><li><strong>Annual maintenance:<\/strong> a tag or label with month, year, technician name and company.<\/li><li><strong>Six-year maintenance:<\/strong> a label showing month and year, technician and company, with the old label removed when the new one is fitted.<\/li><li><strong>Verification-of-service collar:<\/strong> fitted around the cylinder neck after internal examination or recharge, punched with month and year and the service company&#8217;s name.<\/li><li><strong>Hydrostatic test:<\/strong> a metallic label on low-pressure cylinders with date, test pressure and tester; high-pressure cylinders such as CO2 are stamped.<\/li><\/ul>\n<p>Make these markings the contractor&#8217;s responsibility, and require a paper or electronic log after every visit. To organise the log itself, see the <a href=\"\/en\/sa\/media-center\/fire-safety-log-book-records-inspection\/\">fire safety log book guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23d9121 elementor-widget elementor-widget-text-editor\" data-id=\"23d9121\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Maintenance contracts, Salamah and Civil Defense<\/h2>\n<p>Salamah is the Civil Defense e-platform for safety licensing. It handles submission of technical reports and safety equipment installation certificates and lists accredited companies and offices. The documents needed at issue or renewal depend on the requirements for each activity, so check them for your activity before drafting the contract, and keep the contract outputs (reports, log, tags) ready to show.<\/p>\n<p>AZEIDK GROUP issues the safety equipment installation certificate itself and handles the technical report through an approved engineering consultancy office, as part of our <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8b81a3 elementor-widget elementor-widget-text-editor\" data-id=\"c8b81a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes in extinguisher maintenance contracts<\/h2>\n<ul><li>No inventory annex, so nobody knows which units were serviced.<\/li><li>&#8220;Comprehensive maintenance&#8221; with no statement on hydrostatic testing or emergency recharge.<\/li><li>Pulling all units for recharge at once and leaving corridors without cover.<\/li><li>Tracking visit dates instead of each unit&#8217;s manufacture and test dates, so six-year and hydro deadlines are missed.<\/li><li>Records kept by the contractor and lost when the contractor changes.<\/li><li>Combining extinguisher and fire system maintenance with CCTV and low current maintenance in one contract. Those systems normally run under a separate contract with its own scope and technicians.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e65e3f7 elementor-widget elementor-widget-text-editor\" data-id=\"e65e3f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How AZEIDK GROUP handles extinguisher maintenance<\/h2>\n<p>AZEIDK GROUP maintains fire extinguishers with its own maintenance team, within our <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">preventive and periodic maintenance<\/a> contracts for fire and life safety systems, and the service is also available without an annual contract. The work includes an agreed visit schedule, a report after each visit with findings and corrective actions, and an updated maintenance log. For faults between visits there is <a href=\"\/en\/sa\/services\/corrective-maintenance-technical-support\/\">corrective maintenance and technical support<\/a>.<\/p>\n<p>When a damaged or expired unit needs replacing, it can be supplied from the <a href=\"\/en\/sa\/products\/?product_category=fire-extinguishers\">fire extinguishers available from AZEIDK GROUP<\/a>, including Falcon Gold dry powder, CO2, foam and wet chemical units. For step-by-step service and recharge procedures, see our <a href=\"\/en\/sa\/media-center\/fire-extinguisher-maintenance-refill\/\">fire extinguisher maintenance and refill guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d8ad83 elementor-widget elementor-widget-text-editor\" data-id=\"3d8ad83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2><div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>How often should fire extinguishers be serviced?<\/h3><\/summary><p>Under NFPA 10: a monthly visual inspection, annual maintenance by a trained technician, six-yearly internal examination for stored-pressure dry chemical units, and hydrostatic testing every 5 or 12 years depending on type.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can facility staff do the monthly inspection?<\/h3><\/summary><p>Yes. The monthly check is visual and can be done by the owner&#8217;s trained staff, recording the date and initials. Annual maintenance and recharging need a trained technician.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is hydrostatic testing included in an extinguisher maintenance contract?<\/h3><\/summary><p>It depends on the wording. It may be in the contract price or priced per unit due, so the contract should say whether it is included, who performs it and where.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Who provides a replacement while an extinguisher is being recharged?<\/h3><\/summary><p>The contract should place this on the contractor. NFPA 10 requires the replacement to suit the hazard and have at least an equal rating.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>When should an extinguisher be replaced instead of recharged?<\/h3><\/summary><p>When it fails the hydrostatic test or the cylinder is damaged or corroded. Non-rechargeable units are removed from service 12 years after manufacture.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Can extinguisher and CCTV maintenance share one contract?<\/h3><\/summary><p>Keep them separate. Extinguishers belong to the fire and life safety contract; CCTV and low current systems have their own contract, scope and technicians.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86b9529 elementor-widget elementor-widget-text-editor\" data-id=\"86b9529\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>An extinguisher maintenance contract is measured by what it proves: a full inventory, a schedule tied to each unit&#8217;s dates, written responsibilities, cover while units are away, and a log that stays with the owner. Write these clauses before signing, and check every visit report against the inventory annex.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efcf138 elementor-widget elementor-widget-text-editor\" data-id=\"efcf138\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Preparing a maintenance contract for your extinguishers?<\/strong> Send us the number, types and locations of your units, and we will prepare the visit scope, inspection schedule and reporting format. <a href=\"\/en\/sa\/contact\/\">Contact the AZEIDK GROUP team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60b6c49 elementor-widget elementor-widget-text-editor\" data-id=\"60b6c49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.health.mn.gov\/facilities\/regulation\/engineering\/lscfireext24.pdf\" rel=\"noopener\" target=\"_blank\">Portable Fire Extinguishers: Inspection, Maintenance and Testing (NFPA 10)<\/a> (Minnesota Department of Health), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.157\" rel=\"noopener\" target=\"_blank\">29 CFR 1910.157 Portable fire extinguishers<\/a> (OSHA), <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/10\/10_SDR_A2025.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 10 Second Draft Report, Annual 2025 cycle<\/a> (NFPA), <a href=\"https:\/\/saso.gov.sa\/en\/Laws-And-Regulations\/Technical_regulations\/Documents\/TR%20-%20Fire%20Control%20Materials%20and%20Equipment.pdf\" rel=\"noopener\" target=\"_blank\">Technical Regulation for Fire Control Materials and Equipment<\/a> (SASO), <a href=\"https:\/\/elm.sa\/ar\/our-business\/digital-products\/Documents\/En\/Salamah%20EN.pdf\" rel=\"noopener\" target=\"_blank\">Salamah platform overview<\/a> (Elm)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire extinguisher maintenance contract checklist for Saudi buildings: clauses, NFPA 10 monthly, annual and hydrostatic test schedule, and who is responsible.<\/p>\n","protected":false},"author":0,"featured_media":29789,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,329,322],"tags":[],"azeidk_region":[223],"class_list":["post-29794","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-operation-maintenance-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29794"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29794\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29789"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29794"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29794"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}