{"id":29665,"date":"2026-11-23T13:12:49","date_gmt":"2026-11-23T10:12:49","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T13:12:51","modified_gmt":"2026-11-23T10:12:51","slug":"context-plus-addressable-loop-sounders-saudi","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/context-plus-addressable-loop-sounders-saudi\/","title":{"rendered":"Context Plus Addressable Sounders: Loop-Powered Sounders and Sounder Beacons, Models, Sound Levels and Where Each Goes"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29665\" class=\"elementor elementor-29665 elementor-29664 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cb778c4 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"cb778c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-051f414 elementor-widget elementor-widget-text-editor\" data-id=\"051f414\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">An <strong>addressable sounder<\/strong> takes its power and commands from the fire alarm loop itself, so it does not need a separate sounder circuit from the panel as a conventional system does. AZEIDK supplies the Context Plus range in Saudi Arabia: compact wall and ceiling sounders, 103 dB hi-output sounders, sounder beacons that combine sound and light, and IP65 open-area sounders. This guide sorts the models by location and sound level, from the product pages and catalogue.<\/p>\n<p>The devices are part of <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">AZEIDK fire alarm systems<\/a>. For the general picture of bells, sounders and strobes see <a href=\"\/en\/sa\/media-center\/fire-alarm-bell-sounder-strobe-saudi\/\">fire alarm bells, sounders and strobes<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59c5259 elementor-widget elementor-widget-text-editor\" data-id=\"59c5259\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>An addressable sounder runs from the loop; most Context Plus models include a short-circuit isolator and group addressing to operate several devices together.<\/li><li>For offices and corridors: the compact CON450A\/CX\/SR at 91 dB(A) at one metre.<\/li><li>For large or noisy spaces: the CON430A\/CX\/DR wall sounder at 103 dB(A) with 7 volume levels.<\/li><li>Where a visual alarm is needed: CON451A\/CX\/SR and CON433A\/CX\/DR with EN54-23 beacons.<\/li><li>For warehouses, car parks and exposed areas: 55000-001 and 55000-005IMC at 100 dB(A) with IP65 protection.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cf6978 elementor-widget elementor-widget-text-editor\" data-id=\"4cf6978\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Addressable vs conventional sounders<\/h2>\n<p>In a conventional system the panel provides separate sounder circuits, each with its own cable and end-of-line resistor, and every sounder on the circuit operates together. An addressable sounder sits on the same loop cable as the detectors and call points and has an address the panel knows, so the panel monitors it and operates it according to the cause and effect matrix. Group addressing lets a whole group operate at once. To drive conventional sounders from an addressable panel there is the <a href=\"\/en\/sa\/media-center\/sounder-control-unit-55000-852imc-addressable\/\">55000-852IMC sounder control unit<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4945901 elementor-widget elementor-widget-text-editor\" data-id=\"4945901\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Context Plus models from the product pages<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Model<\/th><th>Type<\/th><th>Sound at 1 m<\/th><th>Product page notes<\/th><\/tr><\/thead><tbody>\n<tr><td><a href=\"\/en\/sa\/products\/compact-91dba-wall-ceiling-sounder-con450a-cx-sr\/\">CON450A\/CX\/SR<\/a><\/td><td>Compact wall\/ceiling sounder<\/td><td>91 dB(A)<\/td><td>Onboard isolator, third-party certified to EN54-3 and EN54-17, IP21C, 5 mA alarm current<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/compact-wall-ceiling-sounder-beacon-beacon-only-con451a-cx-sr-con458a-cx-sr\/\">CON451A\/CX\/SR<\/a><\/td><td>Compact sounder beacon<\/td><td>91 dB(A)<\/td><td>EN54-3, EN54-17 and EN54-23; C-3-8 on ceiling, W-3-2.1 on wall; 14 mA alarm current<\/td><\/tr>\n<tr><td>CON458A\/CX\/SR<\/td><td>Beacon only<\/td><td>No sound<\/td><td>EN54-17 and EN54-23; 10 mA alarm current<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/hi-output-103dba-wall-sounders-con430a-cx-dr-con430a-cx-dr-65\/\">CON430A\/CX\/DR<\/a><\/td><td>Hi-output wall sounder<\/td><td>103 dB(A)<\/td><td>7 volume levels, up to 15 tone pairs, LPCB certified to EN54-3 and EN54-17, 5 mA alarm current; IP65 version available<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/hi-output-wall-beacon-with-103dba-sounder-deep-base-con433a-cx-dr\/\">CON433A\/CX\/DR<\/a><\/td><td>Hi-output wall beacon sounder<\/td><td>103 dB(A)<\/td><td>LPCB certified to EN54-3, EN54-17 and EN54-23; W-2.4-8.2; IP65 version available<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/intelligent-open-area-sounder-55000-001\/\">55000-001<\/a><\/td><td>Open-area sounder<\/td><td>100 dB(A) at 90\u00b0<\/td><td>Loop powered, IP65, isolating base supplied, EN54-3:2001<\/td><\/tr>\n<tr><td><a href=\"\/en\/sa\/products\/open-area-sounder-beacon-red-lens-ip65-55000-005imc\/\">55000-005IMC<\/a><\/td><td>Open-area sounder beacon<\/td><td>100 dB(A)<\/td><td>Red lens, built-in isolator, IP65, EN 54-3 and LPCB approved, typically about 15 per loop subject to loading<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Approvals differ by model: some pages name the LPCB, others state third-party certification without naming the body. Submittals should quote only what is written for each model.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb76960 elementor-widget elementor-widget-text-editor\" data-id=\"cb76960\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where each type goes<\/h2>\n<ul>\n<li><strong>Offices, hotels, corridors and classrooms:<\/strong> the compact CON450A, or the CON451A sounder beacon where a visual alarm is also needed, for example for people with hearing impairment.<\/li>\n<li><strong>Factories, plant rooms and large halls:<\/strong> the 103 dB(A) CON430A or CON433A, set to one of 7 volume levels so the alarm stands above ambient noise. See <a href=\"\/en\/sa\/media-center\/industrial-fire-alarm-systems-high-noise-factories\/\">industrial fire alarm systems<\/a>.<\/li>\n<li><strong>Warehouses, car parks and exposed areas:<\/strong> 55000-001 or 55000-005IMC with IP65, or the IP65 versions of the wall sounders. For outdoor devices generally see <a href=\"\/en\/sa\/media-center\/weatherproof-outdoor-fire-alarm-sounder-ip65\/\">IP65 outdoor fire alarm sounders<\/a>.<\/li>\n<li><strong>Hotel and hospital rooms:<\/strong> a sounder in the detector base may suit better; see <a href=\"\/en\/sa\/media-center\/smoke-detector-bases-sounder-isolator-relay\/\">smoke detector bases<\/a>.<\/li>\n<li><strong>Where a spoken evacuation message is needed:<\/strong> choose a <a href=\"\/en\/sa\/media-center\/addressable-voice-sounder-context-plus\/\">voice sounder<\/a> instead of a tone.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c550e2f elementor-widget elementor-widget-text-editor\" data-id=\"c550e2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Loop loading: why sounder current matters<\/h2>\n<p>Every addressable sounder draws loop current in alarm, and the models differ widely: 5 mA for the CON450A or CON430A and 14 mA for the CON451A or CON433A sounder beacons, per the product pages. That is why the 55000-005IMC page gives a typical figure of about 15 units per loop and requires a loop-loading calculation. Many visual devices on one loop can exceed what the loop can supply, so the load is spread over more loops or handled another way in the design. For device and isolator distribution see <a href=\"\/en\/sa\/media-center\/addressable-fire-alarm-loop-design\/\">addressable loop design<\/a> and <a href=\"\/en\/sa\/media-center\/loop-isolator-addressable-fire-alarm-55000-720\/\">loop isolators<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe9ccbc elementor-widget elementor-widget-text-editor\" data-id=\"fe9ccbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>EN54-23 beacon coverage codes<\/h2>\n<p>Devices with a beacon carry a light distribution code such as C-3-8 for ceiling mounting and W-3-2.1 or W-2.4-8.2 for wall mounting. The letter shows the mounting type and the numbers describe the size of the covered space in metres. See <a href=\"\/en\/sa\/media-center\/fire-alarm-flasher-en-54-23-visual-alarm-devices\/\">EN 54-23 visual alarm devices<\/a> for how to read them.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9dd3bab elementor-widget elementor-widget-text-editor\" data-id=\"9dd3bab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>What is an addressable sounder?<\/h3><\/summary><p>An audible alarm device on the addressable loop that takes power and commands from it and has an address the panel monitors.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How loud are Context Plus addressable sounders?<\/h3><\/summary><p>By model: 91 dB(A) for the compact CON450A, 103 dB(A) for the CON430A wall sounder and 100 dB(A) for the open-area units.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does an addressable sounder need its own cable?<\/h3><\/summary><p>No, it sits on the loop cable, but the loop load must be calculated because each device draws current in alarm.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How many sounder beacons per loop?<\/h3><\/summary><p>The 55000-005IMC page gives about 15 per loop as a typical value; the final number comes from the design&#8217;s loading calculation.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is there an addressable sounder for outdoor use?<\/h3><\/summary><p>Yes, such as the 55000-001 and 55000-005IMC with IP65, and IP65 versions of the CON430A and CON433A.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What does the built-in isolator do?<\/h3><\/summary><p>It isolates the affected section when a cable short occurs, so the rest of the loop keeps working.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da06637 elementor-widget elementor-widget-text-editor\" data-id=\"da06637\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Specifying sounders for an addressable project?<\/strong> Send the drawing and the type of each space, and the AZEIDK team will propose the model and sound level and calculate the loop load. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17c7562 elementor-widget elementor-widget-text-editor\" data-id=\"17c7562\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> Context Plus product pages on the AZEIDK site: <a href=\"\/en\/sa\/products\/compact-91dba-wall-ceiling-sounder-con450a-cx-sr\/\">CON450A<\/a>, <a href=\"\/en\/sa\/products\/compact-wall-ceiling-sounder-beacon-beacon-only-con451a-cx-sr-con458a-cx-sr\/\">CON451A and CON458A<\/a>, <a href=\"\/en\/sa\/products\/hi-output-103dba-wall-sounders-con430a-cx-dr-con430a-cx-dr-65\/\">CON430A<\/a>, <a href=\"\/en\/sa\/products\/hi-output-wall-beacon-with-103dba-sounder-deep-base-con433a-cx-dr\/\">CON433A<\/a>, <a href=\"\/en\/sa\/products\/intelligent-open-area-sounder-55000-001\/\">55000-001<\/a> and <a href=\"\/en\/sa\/products\/open-area-sounder-beacon-red-lens-ip65-55000-005imc\/\">55000-005IMC<\/a>, and the <a href=\"\/wp-content\/uploads\/2026\/07\/Contextplus_addressable_sounders_beacons.pdf\" rel=\"noopener\" target=\"_blank\">Context Plus addressable sounders and beacons catalogue<\/a>.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Context Plus addressable fire alarm sounders: CON450A, CON430A, CON451A, CON433A and 55000-001 models, 91 to 103 dB(A), loop loading and where each fits.<\/p>\n","protected":false},"author":0,"featured_media":29663,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,325,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-29665","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-buyers-guide-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29665","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29665"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29665\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29663"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29665"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29665"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29665"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29665"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}