{"id":29649,"date":"2026-11-23T13:06:56","date_gmt":"2026-11-23T10:06:56","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T13:06:57","modified_gmt":"2026-11-23T10:06:57","slug":"fire-check-valve-brands-afc-shurjoint-ubw","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-check-valve-brands-afc-shurjoint-ubw\/","title":{"rendered":"Fire Protection Check Valves Compared: AFC, Shurjoint and United Brass Works by Type, Size and Approval"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29649\" class=\"elementor elementor-29649 elementor-29648 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a66bece e-con-full az-el-article e-flex e-con e-parent\" data-id=\"a66bece\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2ab448a elementor-widget elementor-widget-text-editor\" data-id=\"2ab448a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">A <strong>fire protection check valve<\/strong> lets water flow one way and closes automatically when flow stops or reverses. AZEIDK supplies four models from three brands in Saudi Arabia, and each has its own place in the system: the AFC A-3150 (flanged) and A-3500 (grooved) for 2 to 12 in lines, the Shurjoint RCV grooved riser check valve for wet sprinkler risers, and the United Brass Works 99S threaded bronze valve for small-bore lines. This comparison uses AZEIDK&#8217;s product pages only.<\/p>\n<p>All four sit within AZEIDK&#8217;s <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a> scope, alongside the gate, butterfly and alarm valves AZEIDK supplies and installs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b65f96f elementor-widget elementor-widget-text-editor\" data-id=\"b65f96f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>AFC A-3150: flanged swing check, 2 to 12 in, 300 psi working pressure, UL listed and FM approved per the catalogue.<\/li><li>AFC A-3500: grooved swing check with spring-assisted closing, 2 to 12 in, 350 psi, horizontal or vertical.<\/li><li>Shurjoint RCV: grooved riser check for wet systems, single clapper with dual springs for non-slam closing, tested to UL 312, 300 psi, 2\u00bd in and up.<\/li><li>United Brass Works 99S: threaded bronze, 1\/4 to 2 in, 200 WOG, for small lines such as jockey pump discharge, trim piping and test connections.<\/li><li>Selection starts with the valve&#8217;s position, line size and end type, then working pressure and the required approval.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e49e79 elementor-widget elementor-widget-text-editor\" data-id=\"1e49e79\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Check valve comparison table<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Item<\/th><th>AFC A-3150<\/th><th>AFC A-3500<\/th><th>Shurjoint RCV<\/th><th>UBW 99S<\/th><\/tr><\/thead><tbody>\n<tr><td>Type<\/td><td>Swing<\/td><td>Swing, spring assisted<\/td><td>Single clapper, dual springs (non-slam)<\/td><td>Swing, soft disc<\/td><\/tr>\n<tr><td>Ends<\/td><td>Flanged, ANSI B16.1 Class 125 \/ B16.42 Class 150<\/td><td>Grooved (AWWA C606 or metric)<\/td><td>Grooved, NPT or BSP side ports<\/td><td>Threaded<\/td><\/tr>\n<tr><td>Sizes<\/td><td>2 to 12 in<\/td><td>2 to 12 in<\/td><td>2\u00bd in and up<\/td><td>1\/4 to 2 in<\/td><\/tr>\n<tr><td>Max working pressure<\/td><td>300 psi (21 bar)<\/td><td>350 psi (24 bar)<\/td><td>300 psi (20 bar)<\/td><td>200 WOG at 180\u00b0F<\/td><\/tr>\n<tr><td>Test pressure<\/td><td>600 psi<\/td><td>700 psi<\/td><td>Not stated<\/td><td>100% pressure tested<\/td><\/tr>\n<tr><td>Published approval<\/td><td>UL and FM per catalogue<\/td><td>UL and FM per catalogue<\/td><td>Tested to UL 312<\/td><td>Not stated on the page<\/td><\/tr>\n<tr><td>Body<\/td><td>Epoxy-coated ductile iron<\/td><td>Epoxy-coated ductile iron, stainless disc and spring<\/td><td>Ductile iron<\/td><td>Bronze<\/td><\/tr>\n<tr><td>Orientation<\/td><td>Not stated<\/td><td>Horizontal or vertical<\/td><td>Horizontal or vertical<\/td><td>Per datasheet; not on its side<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a98c19c elementor-widget elementor-widget-text-editor\" data-id=\"a98c19c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>AFC A-3150 and A-3500: main line valves<\/h2>\n<p>The <a href=\"\/en\/sa\/products\/american-afc-flanged-swing-check-valve-a-3150\/\">AFC A-3150<\/a> is a flanged swing check with ductile iron body and disc, EPDM seal, bronze seat ring and 304 stainless hinge pin, epoxy coated inside and out to AWWA C550 and meeting AWWA C508. The <a href=\"\/en\/sa\/products\/american-afc-grooved-swing-check-valve-a-3500\/\">AFC A-3500<\/a> is grooved, with stainless disc, spring and fasteners, a C95400 bronze seat and a higher 350 psi rating, installed horizontally or vertically. In practice the choice between them is the end type: flanged for pump rooms and flanged mains, grooved for grooved networks. Where each goes is covered in our article on the <a href=\"\/en\/sa\/media-center\/afc-swing-check-valve-fire-network\/\">AFC swing check valve<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be33360 elementor-widget elementor-widget-text-editor\" data-id=\"be33360\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Shurjoint RCV: a riser check valve<\/h2>\n<p>The <a href=\"\/en\/sa\/products\/shurjoint-rcv-grooved-riser-check-valve\/\">Shurjoint RCV<\/a> is designed for wet sprinkler risers, with a single clapper and dual springs that close without slamming, a streamlined low-loss body and vertical or horizontal installation. It is tested to UL 312 and rated 300 psi, with NPT or BSP side ports for trim. More in our article on the <a href=\"\/en\/sa\/media-center\/shurjoint-rcv-riser-check-valve\/\">Shurjoint RCV riser check valve<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e698c4a elementor-widget elementor-widget-text-editor\" data-id=\"e698c4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>United Brass Works 99S: for small-bore lines<\/h2>\n<p>The <a href=\"\/en\/sa\/products\/united-brass-works-model-99s-swing-check-valve\/\">UBW 99S<\/a> is a bronze swing check with a soft Buna-N disc, stainless hinge and threaded ends from 1\/4 to 2 in, rated 200 WOG at 180\u00b0F and 100% pressure tested. Listed uses are back-flow prevention on small lines such as jockey pump discharge, trim piping and test connections. The manufacturer notes it is not recommended for pulsating or vibrating service, must not be installed on its side, and contains lead, so it is not for potable water. It also appears in our article on <a href=\"\/en\/sa\/media-center\/osy-gate-ball-valves-ubw-apollo-saudi\/\">UBW and Apollo valves<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a77ded elementor-widget elementor-widget-text-editor\" data-id=\"4a77ded\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Which check valve should you choose?<\/h2>\n<ol><li><strong>Fix its position:<\/strong> fire pump discharge and mains, a sprinkler riser, or a small line such as jockey pump discharge or the fire department connection.<\/li><li><strong>Match the size:<\/strong> small threaded lines up to 2 in suit the 99S; 2 to 12 in lines point to AFC or RCV depending on the ends.<\/li><li><strong>Match the ends:<\/strong> flanged (A-3150) or grooved (A-3500 or RCV).<\/li><li><strong>Check working pressure:<\/strong> in towers and high-pressure systems the difference between 300 and 350 psi can matter.<\/li><li><strong>Read the required approval<\/strong> and match it to each product page and datasheet.<\/li><\/ol>\n<p>At the fire department connection the check valve is part of the assembly; see our <a href=\"\/en\/sa\/media-center\/fire-department-connection-guide\/\">fire department connection guide<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-504df4d elementor-widget elementor-widget-text-editor\" data-id=\"504df4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common mistakes<\/h2>\n<ul><li>Installing a check valve against the flow arrow cast on the body.<\/li><li>Using a small threaded bronze valve on a main line beyond its range.<\/li><li>Installing a valve vertically when its datasheet does not allow it, or fitting the 99S on its side.<\/li><li>Ignoring water hammer when flow stops in a riser; the Shurjoint RCV is designed to close without slamming for this reason.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9944b19 elementor-widget elementor-widget-text-editor\" data-id=\"9944b19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>What does a check valve do in a fire protection system?<\/h3><\/summary><p>It lets water flow one way and closes automatically when flow stops or reverses, protecting pumps and piping from back-flow.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is the difference between the AFC A-3150 and A-3500?<\/h3><\/summary><p>The A-3150 is flanged and rated 300 psi; the A-3500 is grooved with spring-assisted closing and rated 350 psi. Both cover 2 to 12 in.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Which check valve suits a sprinkler riser?<\/h3><\/summary><p>The Shurjoint RCV is designed for wet system risers, closes without slamming and is tested to UL 312.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Which check valve suits a jockey pump discharge?<\/h3><\/summary><p>The line is usually small, and the threaded bronze UBW 99S (1\/4 to 2 in) lists this use among its applications.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Can a check valve be installed vertically?<\/h3><\/summary><p>The AFC A-3500 and Shurjoint RCV can be installed horizontally or vertically per their pages; for the others, follow the datasheet.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85388c2 elementor-widget elementor-widget-text-editor\" data-id=\"85388c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Summary<\/h2>\n<p>There is no single check valve for every position. The AFC A-3150 and A-3500 serve main lines by end type, the Shurjoint RCV serves sprinkler risers, and the UBW 99S serves small-bore lines. Fix the position, size, ends, pressure and approval, then choose. The AZEIDK team handles supply, installation and testing.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72a2528 elementor-widget elementor-widget-text-editor\" data-id=\"72a2528\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Need check valves for a project?<\/strong> Send your drawings or BOQ with sizes and end types, and the AZEIDK team will recommend the right model for each position. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire protection check valves compared from the product pages: AFC A-3150 and A-3500, Shurjoint RCV and UBW 99S by type, ends, sizes, pressure and approval.<\/p>\n","protected":false},"author":0,"featured_media":29647,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-29649","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29649"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29649\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29647"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29649"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29649"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29649"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}