{"id":29555,"date":"2026-11-23T12:38:39","date_gmt":"2026-11-23T09:38:39","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T12:38:40","modified_gmt":"2026-11-23T09:38:40","slug":"fire-pumps-riyadh","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-pumps-riyadh\/","title":{"rendered":"Fire Pumps in Riyadh: Choosing Pumps for Towers, Warehouses and Factories, Supplied by AZEIDK"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29555\" class=\"elementor elementor-29555 elementor-29554 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5704085 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"5704085\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cadeb09 elementor-widget elementor-widget-text-editor\" data-id=\"cadeb09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Fire pumps in Riyadh<\/strong> are usually ordered by contractors on towers and compounds, owners of warehouses and factories in the industrial cities, and owners of existing buildings replacing an old pump. The right question is not &#8220;what does a pump cost?&#8221; but: what flow and pressure does the design need, where is the water level relative to the pump, and does the consultant require a UL listed or FM approved unit? Once those are answered, choosing the model is straightforward.<\/p>\n<p>AZEIDK supplies fire pumps from SFFECO, WATEX and Jack Pump, plus non-listed 3PUMP packages, shown in the <a href=\"\/en\/sa\/products\/?product_category=fire-pumps\">fire pumps section<\/a> under <a href=\"\/en\/sa\/solutions\/fire-fighting-systems\/\">fire fighting systems<\/a>. If the consultant specifies another brand, the supply team works to source it to the required approvals. For a detailed comparison of pump types see <a href=\"\/en\/sa\/media-center\/fire-pump-types-selection-saudi\/\">fire pump types and selection<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a19b09 elementor-widget elementor-widget-text-editor\" data-id=\"3a19b09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>Pump size comes from the hydraulic calculations of the approved design, not from floor area alone.<\/li><li>The water source decides the type: a tank above the pump suits end suction or split case; water below the pump usually needs a vertical turbine.<\/li><li>The SASO technical regulation requires a certificate of conformity for fire pumps, issued through the SABER platform.<\/li><li>Riyadh heat and dust make pump room ventilation and the care of batteries and filters part of design and maintenance.<\/li><li>AZEIDK has a Riyadh office, two showrooms and a warehouse in Al Yasmin.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a506856 elementor-widget elementor-widget-text-editor\" data-id=\"a506856\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What do Riyadh facilities need from a fire pump?<\/h2>\n<p>Riyadh mixes office and residential towers, warehouses, factories and hospitals, and each needs something different from the pump set:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Facility<\/th><th>What drives pump selection<\/th><th>Practical note<\/th><\/tr><\/thead><tbody>\n<tr><td>Office and residential towers<\/td><td>Pressure needed at the top floor<\/td><td>Pressure zones or pressure reducing valves may be used per design<\/td><\/tr>\n<tr><td>Warehouses and logistics<\/td><td>Storage height and commodity in the sprinkler design<\/td><td>High-piled storage pushes required flow up sharply<\/td><\/tr>\n<tr><td>Factories in industrial cities<\/td><td>Largest water demand across sprinklers, hydrants and any foam system<\/td><td>Often an electric pump, a standby diesel pump and a jockey pump<\/td><\/tr>\n<tr><td>Hospitals<\/td><td>Sprinklers in every department and continuity during maintenance<\/td><td>Any pump shutdown is planned in advance with hospital management<\/td><\/tr>\n<tr><td>Residential compounds<\/td><td>Sprinklers, hose cabinets and hydrants across separate buildings<\/td><td>Usually a shared ground tank and a single pump room<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>For towers see <a href=\"\/en\/sa\/media-center\/high-rise-building-fire-pumps-saudi-en\/\">fire pumps for high-rise buildings<\/a>, and for PRVs see <a href=\"\/en\/sa\/media-center\/fire-pressure-reducing-valve-prv\/\">fire pressure reducing valves<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ac1d65 elementor-widget elementor-widget-text-editor\" data-id=\"6ac1d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Choosing a fire pump in Riyadh by water source and flow<\/h2>\n<p>Start with three numbers from the designer: flow in gallons per minute (GPM), required pressure, and water level relative to the pump centreline. Then pick the type:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Pump type<\/th><th>When it fits<\/th><th>Available from AZEIDK<\/th><\/tr><\/thead><tbody>\n<tr><td>End suction<\/td><td>Small to medium flows, water above the pump<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-end-suction-fire-pump-ves-series\/\">Jack Pump VES series<\/a> (UL listed) and <a href=\"\/en\/sa\/products\/watex-we-end-suction-fire-pump-ul-fm\/\">WATEX WE series<\/a><\/td><\/tr>\n<tr><td>Split case<\/td><td>Larger flows for big factories and warehouses<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-split-case-fire-pump-msc-series\/\">Jack Pump MSC series<\/a> and <a href=\"\/en\/sa\/products\/watex-ws-split-case-fire-pump-ul\/\">WATEX WS series<\/a><\/td><\/tr>\n<tr><td>Vertical turbine<\/td><td>Water below the pump, such as deep ground tanks<\/td><td><a href=\"\/en\/sa\/products\/jack-pump-ul-listed-vertical-turbine-fire-pump-vtp-series\/\">Jack Pump VTP series<\/a> and <a href=\"\/en\/sa\/products\/watex-vertical-turbine-fire-pump-ul\/\">WATEX vertical turbine<\/a><\/td><\/tr>\n<tr><td>Non-UL packages<\/td><td>Projects whose specification does not require a listing<\/td><td><a href=\"\/en\/sa\/products\/3pump-fire-pump-packages\/\">3PUMP packages<\/a>: electric, diesel and jockey<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>We do not quote a size before the calculations. The method is in <a href=\"\/en\/sa\/media-center\/fire-pump-calculation-sizing-nfpa-20\/\">fire pump sizing to NFPA 20<\/a>, and a brand comparison in <a href=\"\/en\/sa\/media-center\/jack-pump-vs-watex-fire-pumps-saudi\/\">Jack Pump vs WATEX<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6d84a3 elementor-widget elementor-widget-text-editor\" data-id=\"e6d84a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Documents and approvals in Riyadh<\/h2>\n<ul><li><strong>Calculations and drawings:<\/strong> the engineering office sets flow, pressure, tank size and the pump room.<\/li><li><strong>Submittal:<\/strong> the supplier provides the datasheet, performance curve and listing certificate (UL 448 or FM) where specified, plus controller and driver details.<\/li><li><strong>SABER conformity:<\/strong> the SASO <a href=\"https:\/\/saso.gov.sa\/en\/Laws-And-Regulations\/Technical_regulations\/Documents\/TR%20-%20Fire%20Control%20Materials%20and%20Equipment.pdf\" rel=\"noopener\" target=\"_blank\">technical regulation for fire control materials and equipment<\/a> requires a certificate of conformity for fire pumps.<\/li><li><strong>Testing and commissioning:<\/strong> an on-site performance test witnessed by the consultant before handover, under <a href=\"\/en\/sa\/services\/testing-commissioning-handover\/\">testing, commissioning and handover<\/a>.<\/li><li><strong>Salamah licence:<\/strong> AZEIDK handles the technical report through an approved engineering consultancy office and issues the safety equipment installation certificate for the systems it installs. See <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5844a18 elementor-widget elementor-widget-text-editor\" data-id=\"5844a18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pump rooms in Riyadh heat and dust<\/h2>\n<ul><li><strong>Ventilation and heat:<\/strong> a diesel pump needs enough combustion and cooling air, and summer heat builds up quickly in a poorly ventilated room.<\/li><li><strong>Batteries:<\/strong> diesel starting batteries age faster in heat and need regular checks.<\/li><li><strong>Dust:<\/strong> it collects on air filters and panels, so cleaning is part of routine maintenance.<\/li><li><strong>Fuel:<\/strong> diesel tank level and condition are checked on each visit.<\/li><\/ul>\n<p>Diesel pump components are covered in <a href=\"\/en\/sa\/media-center\/diesel-fire-pump-components-nfpa20\/\">diesel fire pump components and NFPA 20<\/a>, and controller service in <a href=\"\/en\/sa\/media-center\/fire-pump-controller-maintenance-testing\/\">fire pump controller maintenance<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cea62f elementor-widget elementor-widget-text-editor\" data-id=\"9cea62f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>AZEIDK branches in Riyadh<\/h2>\n<p>Details as shown on the contact page:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Branch<\/th><th>Address<\/th><th>Phone<\/th><\/tr><\/thead><tbody>\n<tr><td>Riyadh office<\/td><td>Salah Al Din Street, Al Malaz<\/td><td><a href=\"tel:+966543760300\">+966 543760300<\/a><\/td><\/tr>\n<tr><td>Riyadh showroom, Salah Al Din Street<\/td><td>Salah Al Din Street, Al Malaz<\/td><td><a href=\"tel:+966543647373\">+966 543647373<\/a><\/td><\/tr>\n<tr><td>Riyadh showroom, Al Dhahran Street<\/td><td>Al Dhahran Street<\/td><td><a href=\"tel:+966543667373\">+966 543667373<\/a><\/td><\/tr>\n<tr><td>Riyadh warehouse<\/td><td>Al Yasmin<\/td><td>\u2013<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Project pump orders usually start at the office with the calculations or bill of quantities. Spare parts and accessories can be checked at the nearest showroom. If the existing pump is old, see <a href=\"\/en\/sa\/media-center\/fire-pump-replacement-existing-building-en\/\">replacing a fire pump in an existing building<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a86838 elementor-widget elementor-widget-text-editor\" data-id=\"5a86838\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>Where can I buy a fire pump in Riyadh?<\/h3><\/summary><p>AZEIDK supplies Jack Pump, WATEX and SFFECO pumps and 3PUMP packages; project orders start at the Riyadh office.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What size fire pump does a Riyadh building need?<\/h3><\/summary><p>The designer sets it from the hydraulic calculations: required flow, pressure and water source, not floor area alone.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Does a fire pump need a SABER certificate?<\/h3><\/summary><p>Yes. The SASO technical regulation for fire control materials and equipment requires a certificate of conformity for fire pumps through SABER.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Do I need a diesel pump as well as an electric one?<\/h3><\/summary><p>The design decides, based on power supply reliability and project requirements; many factories and large facilities use a standby diesel pump.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89e238c elementor-widget elementor-widget-text-editor\" data-id=\"89e238c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Have pump calculations for a Riyadh project?<\/strong> Send the flow, pressure and drawings and AZEIDK will propose the right pump set. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7327057 elementor-widget elementor-widget-text-editor\" data-id=\"7327057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> NFPA 20, the SASO technical regulation for fire control materials and equipment, and Riyadh branch details from the AZEIDK contact page.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire pumps in Riyadh: choosing by flow and water source, Jack Pump, WATEX and 3PUMP options, SABER conformity, and AZEIDK branches in Riyadh.<\/p>\n","protected":false},"author":0,"featured_media":29508,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-29555","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29555"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29555\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29508"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29555"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}