{"id":29553,"date":"2026-11-23T12:38:32","date_gmt":"2026-11-23T09:38:32","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T12:38:33","modified_gmt":"2026-11-23T09:38:33","slug":"fire-rated-doors-jeddah","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/fire-rated-doors-jeddah\/","title":{"rendered":"Fire Doors in Jeddah: Supply and Installation of Fire Rated Doors for Towers, Hotels and Warehouses"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29553\" class=\"elementor elementor-29553 elementor-29552 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cbed617 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"cbed617\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b2ff67 elementor-widget elementor-widget-text-editor\" data-id=\"5b2ff67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Fire doors in Jeddah<\/strong> are mostly ordered by contractors on residential and hotel towers, warehouse owners in Al Khumra and the industrial areas, and owners of existing buildings after a Civil Defense inspector flags a stair or electrical room door. A fire-rated door is not just a heavy steel door. It is a complete tested assembly of leaf, frame, hinges, closer and lock, and its rating in minutes comes from the approved building design.<\/p>\n<p>This guide covers where Jeddah buildings need fire doors, how to choose the door and its hardware, what the humid coastal climate affects, and where to find the AZEIDK branches in Jeddah. AZEIDK supplies <a href=\"\/en\/sa\/products\/fire-rated-steel-doors\/\">fire-rated steel doors<\/a> and installs them as part of its <a href=\"\/en\/sa\/solutions\/fire-rated-doors-emergency-exit-solutions\/\">fire doors and emergency exit solutions<\/a>, and the company&#8217;s head office is in Jeddah.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9c440f elementor-widget elementor-widget-text-editor\" data-id=\"e9c440f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>A fire door is tested and rated as a complete assembly: leaf, frame and hardware together.<\/li><li>The rating for each opening is set by the Saudi Building Code and the approved design, and AZEIDK confirms it with the consultant before supply.<\/li><li>Jeddah&#8217;s humidity affects hinges, closers and locks, so routine cleaning and adjustment are part of maintenance.<\/li><li>Common inspection findings: a stair door wedged open, a failed closer, or a lock that blocks exit.<\/li><li>Jeddah hosts the AZEIDK head office, three safety product showrooms and the main warehouse in Al Khumra.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b6ddbc elementor-widget elementor-widget-text-editor\" data-id=\"6b6ddbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where do Jeddah buildings need fire doors?<\/h2>\n<p>The rule is the same everywhere: a door that separates a hazard or protects an escape route must be fire-rated and self-closing. The character of Jeddah makes some cases more frequent:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Facility in Jeddah<\/th><th>Typical fire door locations<\/th><th>What needs attention<\/th><\/tr><\/thead><tbody>\n<tr><td>Residential and hotel towers<\/td><td>Protected stair doors on every floor, electrical, generator and pump rooms, refuse rooms<\/td><td>Heavy daily use, so closers and hinges must stand up to traffic<\/td><\/tr>\n<tr><td>Warehouses in Al Khumra and industrial areas<\/td><td>Separations between warehouse and offices, electrical and charging rooms<\/td><td>Large openings, plus dust and heat that affect closing if maintenance slips<\/td><\/tr>\n<tr><td>Hospitals and medical centres<\/td><td>Stair doors, cross-corridor doors between departments, electrical rooms<\/td><td>Double doors for bed movement, magnetic holders that release on alarm<\/td><\/tr>\n<tr><td>Malls and commercial buildings<\/td><td>Emergency exit doors, service rooms, back-of-house stores<\/td><td>Panic bars on exit routes, no key needed to get out<\/td><\/tr>\n<tr><td>Residential blocks<\/td><td>Stair door on each floor, meter and tank rooms<\/td><td>Residents wedge doors open, a recurring inspection finding<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The table is a guide; the final reference for each opening is the approved fire protection drawing, which sets the separating walls and their rating, and the door rating follows from it. See also <a href=\"\/en\/sa\/media-center\/fire-door-rating-by-location-saudi\/\">fire door ratings by location<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2258a5b elementor-widget elementor-widget-text-editor\" data-id=\"2258a5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to choose fire doors for a Jeddah project<\/h2>\n<p>Before asking for a quotation, collect this for each door:<\/p>\n<ul><li><strong>Required rating:<\/strong> written in minutes on the approved drawing, never chosen by price.<\/li><li><strong>Clear opening size:<\/strong> width and height after finishes, single or double leaf.<\/li><li><strong>Swing direction:<\/strong> escape route doors usually open in the direction of travel, as the drawing shows.<\/li><li><strong>Glazing:<\/strong> any vision panel must be tested as part of the same assembly.<\/li><li><strong>Hardware:<\/strong> closer, hinges, standard lock or panic bar, coordinator for double doors, and magnetic holder if required.<\/li><li><strong>Interfaces:<\/strong> does the door connect to the fire alarm or the access control system?<\/li><\/ul>\n<p>Fitting untested hardware to a tested door, such as an off-the-shelf lock or handle, voids the assembly rating and shows up at consultant review or inspection. AZEIDK asks for the hardware schedule with the door from the start and reviews <a href=\"\/en\/sa\/services\/drawings-specifications-review\/\">drawings and specifications<\/a> before supply. For closers in particular see <a href=\"\/en\/sa\/media-center\/fire-door-closer-saudi\/\">fire door closers<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab22c3a elementor-widget elementor-widget-text-editor\" data-id=\"ab22c3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>The coastal climate: what it does to a fire door<\/h2>\n<p>Jeddah is hot and humid for most of the year, and that shows in the moving parts more than in the leaf:<\/p>\n<ul><li><strong>Hinges and closers:<\/strong> humidity, salt and dust add friction, so the door closes slowly or not fully. Adjustment and cleaning restore self-closing.<\/li><li><strong>Locks and panic bars:<\/strong> check that the door latches on closing and opens from inside with a single push.<\/li><li><strong>External and roof doors:<\/strong> more exposed to moisture and sun, so they are checked more often.<\/li><li><strong>Paint and frame:<\/strong> any corrosion at the bottom of the frame is treated to the manufacturer&#8217;s instructions without modifying the leaf.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74f52c4 elementor-widget elementor-widget-text-editor\" data-id=\"74f52c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How a fire door gets accepted<\/h2>\n<p>There is no separate approval for the door alone; it passes through the building&#8217;s stages:<\/p>\n<ul><li><strong>Design approval:<\/strong> the engineering office sets door locations and ratings on the fire protection drawing.<\/li><li><strong>Material submittal:<\/strong> the supplier submits the datasheet and the assembly test certificate to the consultant before supply.<\/li><li><strong>Installation and checks:<\/strong> the door goes into a wall of matching rating, and self-closing, latching and gaps are checked.<\/li><li><strong>Salamah licence:<\/strong> the inspector reviews emergency exits and their doors. AZEIDK handles the technical report through an approved engineering consultancy office and issues the safety equipment installation certificate for the work it carries out.<\/li><\/ul>\n<p>Details are on the <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> page, and ordering and receiving steps are in <a href=\"\/en\/sa\/media-center\/fire-rated-doors-saudi\/\">fire-rated doors: how to order and receive them<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40973aa elementor-widget elementor-widget-text-editor\" data-id=\"40973aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>AZEIDK branches in Jeddah<\/h2>\n<p>Details as shown on the contact page:<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Branch<\/th><th>Address<\/th><th>Phone<\/th><\/tr><\/thead><tbody>\n<tr><td>Head office<\/td><td>Jeddah<\/td><td><a href=\"tel:+966581444606\">+966 581444606<\/a> | <a href=\"tel:+966569374142\">+966 569374142<\/a><\/td><\/tr>\n<tr><td>Jeddah showroom, Al Baladiya Street (Al Aziziyah)<\/td><td>Al Baladiya Street, Al Aziziyah<\/td><td><a href=\"tel:+966549294109\">+966 549294109<\/a><\/td><\/tr>\n<tr><td>Jeddah showroom, Al Baladiya Street (next to Raya)<\/td><td>Al Baladiya Street<\/td><td><a href=\"tel:+966543617373\">+966 543617373<\/a><\/td><\/tr>\n<tr><td>Jeddah showroom, Al Sabeen Street<\/td><td>Al Sabeen Street<\/td><td><a href=\"tel:+966543607373\">+966 543607373<\/a><\/td><\/tr>\n<tr><td>Main warehouse<\/td><td>Al Khumra, Jeddah<\/td><td>\u2013<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>For projects, send the door schedule and drawing to the head office and the quotation follows a review of ratings and sizes. For small orders, such as one electrical room door or a stair door in a residential block, visit the nearest showroom.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35c1a14 elementor-widget elementor-widget-text-editor\" data-id=\"35c1a14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Maintenance after handover<\/h2>\n<p>NFPA 80, as an international reference, calls for annual inspection of fire door assemblies with documented results, and doors are part of <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a> along with the fire systems. Inspection items are in <a href=\"\/en\/sa\/media-center\/fire-rated-doors-inspection-maintenance\/\">fire door inspection and maintenance to NFPA 80<\/a>, and cost drivers in <a href=\"\/en\/sa\/media-center\/fire-rated-doors-cost-factors-saudi\/\">fire door cost factors<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8826e10 elementor-widget elementor-widget-text-editor\" data-id=\"8826e10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>Where can I buy fire doors in Jeddah?<\/h3><\/summary><p>AZEIDK supplies and installs fire-rated steel doors. Projects go through the Jeddah head office, and small orders through the nearest showroom.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What fire rating does my door need?<\/h3><\/summary><p>The approved drawing sets it, based on the wall the door sits in and the building type. It is not chosen from the catalogue alone.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Can I fit a standard lock to a fire door?<\/h3><\/summary><p>No. Hardware must be tested with the assembly; an untested lock voids the door&#8217;s rating.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Why has my fire door stopped closing by itself?<\/h3><\/summary><p>Usually closer adjustment or hinge friction from humidity and dust. Adjustment and cleaning during maintenance restore self-closing.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6058cb2 elementor-widget elementor-widget-text-editor\" data-id=\"6058cb2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Have a door schedule for a Jeddah project?<\/strong> Send the drawing and schedule and AZEIDK will check ratings, sizes and hardware before quoting. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2535d8e elementor-widget elementor-widget-text-editor\" data-id=\"2535d8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> Saudi Building Code (SBC 201 and SBC 801), NFPA 80 for periodic inspection, and Jeddah branch details from the AZEIDK contact page.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire doors in Jeddah: where towers, hotels and warehouses need them, choosing doors and hardware, humidity and closers, and AZEIDK branches in Jeddah.<\/p>\n","protected":false},"author":0,"featured_media":29507,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,327,322],"tags":[],"azeidk_region":[223],"class_list":["post-29553","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-by-facility-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29553"}],"version-history":[{"count":0,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29553\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29507"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29553"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29553"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29553"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}