{"id":29540,"date":"2026-05-08T10:00:00","date_gmt":"2026-05-08T07:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T12:35:42","modified_gmt":"2026-11-23T09:35:42","slug":"hikvision-poe-switch-cve-2026-3828-news-en","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/hikvision-poe-switch-cve-2026-3828-news-en\/","title":{"rendered":"Hikvision PoE Switch Vulnerability CVE-2026-3828: Affected Discontinued Models and the Fix"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29540\" class=\"elementor elementor-29540 elementor-29539 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6c5942d e-con-full az-el-article e-flex e-con e-parent\" data-id=\"6c5942d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-24d829e elementor-widget elementor-widget-text-editor\" data-id=\"24d829e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-head\"><div class=\"azn-brand\"><span class=\"azn-tag\">AZEIDK Radar<\/span><span class=\"azn-line\">We track the update before it reaches your site<\/span><\/div><div class=\"azn-meta\"><span>Cybersecurity<\/span><span>National Cybersecurity Authority<\/span><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c06c0a9 elementor-widget elementor-widget-text-editor\" data-id=\"c06c0a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">On 8 May 2026 Hikvision&#8217;s Security Response Center (HSRC) published advisory HSRC-202605-02 on <strong>CVE-2026-3828<\/strong>, a flaw in some <strong>Hikvision PoE switches<\/strong> that the company discontinued in December 2023. On the same date, the national CERT of Saudi Arabia&#8217;s National Cybersecurity Authority (NCA) issued high-severity alert 2026-7462. The news matters because these older switches are still running in many CCTV systems installed years ago.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-571762b elementor-widget elementor-widget-text-editor\" data-id=\"571762b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>CVE-2026-3828 lets an attacker who holds valid credentials execute commands on the switch remotely, due to insufficient input validation.<\/li><li>It scores 7.2 under CVSS v3.1; the NCA alert is classed as high severity.<\/li><li>Three affected models: DS-3E1310P-SI, DS-3E1318P-SI and DS-3E1326P-SI, all discontinued since December 2023.<\/li><li>Hikvision has released fixed firmware for these models despite their discontinued status.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65a1bb7 elementor-widget elementor-widget-text-editor\" data-id=\"65a1bb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Affected models and fixed firmware<\/h2><table><thead><tr><th>Model<\/th><th>Affected version<\/th><th>Fixed version<\/th><\/tr><\/thead><tbody><tr><td>DS-3E1310P-SI<\/td><td>V1.2.4_210623 and earlier<\/td><td>V1.2.5_260309<\/td><\/tr><tr><td>DS-3E1318P-SI<\/td><td>V1.2.0_210823 and earlier<\/td><td>V1.2.1_260309<\/td><\/tr><tr><td>DS-3E1326P-SI<\/td><td>V1.2.0_210823 and earlier<\/td><td>V1.2.1_260309<\/td><\/tr><\/tbody><\/table><p>Source: Hikvision advisory HSRC-202605-02. The affected releases date from 2021, so any of these switches that has not been updated since installation is very likely running an affected version.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6443fa6 elementor-widget elementor-widget-text-editor\" data-id=\"6443fa6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What about current Hikvision switches?<\/h2><p>The advisory names only the three SI models above. The Hikvision PoE switches AZEIDK lists, such as the <a href=\"\/en\/sa\/products\/hikvision-ds-3e1309p-ei-9-port-poe-network-switch\/\">DS-3E1309P-EI<\/a> and <a href=\"\/en\/sa\/products\/hikvision-ds-3e1510p-ei-10-port-poe-network-switch\/\">DS-3E1510P-EI<\/a>, do not appear in this advisory. Keeping any managed switch on current firmware is still good practice, because security advisories keep coming.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1b1f15 elementor-widget elementor-widget-text-editor\" data-id=\"c1b1f15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What it means for facilities in Saudi Arabia<\/h2><p>In a CCTV system the PoE switch powers the cameras and carries their video, so control of the switch means the ability to cut cameras or tamper with network traffic. Because the flaw requires credentials, the switches most at risk are those still on the default password or managed from an open network. Steps: list the Hikvision switches on site and their models, update affected units to the fixed firmware, change the admin password, and separate the CCTV network from guest and user networks. As these models are discontinued, plan to replace them at the next system upgrade.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f22ca7 elementor-widget elementor-widget-text-editor\" data-id=\"5f22ca7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-take\"><h2>AZEIDK view<\/h2><p>The switch is the device everyone forgets after installation, which is exactly why it becomes a weak point. We recommend adding switches to the <a href=\"\/en\/sa\/media-center\/cctv-security-systems-maintenance\/\">CCTV maintenance<\/a> schedule alongside cameras and recorders. If you are planning a replacement, our <a href=\"\/en\/sa\/media-center\/network-switch-types-guide\/\">network switch types guide<\/a> explains managed, unmanaged and PoE options, and <a href=\"\/en\/sa\/solutions\/network-communication-systems\/\">network and communication systems<\/a> covers complete solutions. Our reports on the <a href=\"\/en\/sa\/media-center\/hikvision-wireless-ap-cve-2026-16843-firmware-news-en\/\">Hikvision access point vulnerability<\/a> and <a href=\"\/en\/sa\/media-center\/hikvision-cameras-cve-2026-57600-firmware-update-news-en\/\">vulnerabilities in some Hikvision cameras<\/a> complete the picture for the rest of the network. Inspection and updates can be covered under our <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a>, or you can <a href=\"\/en\/sa\/contact\/\">contact the AZEIDK team<\/a>.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0b0bf9 elementor-widget elementor-widget-text-editor\" data-id=\"f0b0bf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-sources\"><h2>Sources<\/h2><ol><li><a href=\"https:\/\/www.hikvision.com\/en\/support\/cybersecurity\/security-advisory\/command-execution-vulnerability-in-some-hikvision-switch-product\/\" rel=\"nofollow noopener\" target=\"_blank\">Command Execution Vulnerability in Some Hikvision Switch Products (HSRC-202605-02)<\/a>, Hikvision, 8 May 2026<\/li><li><a href=\"https:\/\/nca.gov.sa\/en\/cert\/7582\/\" rel=\"nofollow noopener\" target=\"_blank\">Hikvision Alert 2026-7462<\/a>, National Cybersecurity Authority CERT, 8 May 2026<\/li><\/ol><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Hikvision disclosed CVE-2026-3828 on 8 May 2026 in discontinued PoE switches DS-3E1310P-SI, DS-3E1318P-SI and DS-3E1326P-SI; Saudi NCA issued an alert.<\/p>\n","protected":false},"author":0,"featured_media":29533,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[258],"tags":[],"azeidk_region":[223],"class_list":["post-29540","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29540"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29540\/revisions"}],"predecessor-version":[{"id":29547,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29540\/revisions\/29547"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29533"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29540"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}