{"id":29538,"date":"2026-06-10T10:00:00","date_gmt":"2026-06-10T07:00:00","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-23T12:35:33","modified_gmt":"2026-11-23T09:35:33","slug":"dahua-dhcc-sa-202606-001-cve-2026-29116-news-en","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/dahua-dhcc-sa-202606-001-cve-2026-29116-news-en\/","title":{"rendered":"Dahua Vulnerabilities June 2026 (DHCC-SA-202606-001): CVE-2026-29116 Reaches Cameras, Recorders and Intercoms"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29538\" class=\"elementor elementor-29538 elementor-29537 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2c16f9 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"d2c16f9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f41c433 elementor-widget elementor-widget-text-editor\" data-id=\"f41c433\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-head\"><div class=\"azn-brand\"><span class=\"azn-tag\">AZEIDK Radar<\/span><span class=\"azn-line\">We track the update before it reaches your site<\/span><\/div><div class=\"azn-meta\"><span>Cybersecurity<\/span><span>Dahua<\/span><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d51933e elementor-widget elementor-widget-text-editor\" data-id=\"d51933e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\">On 10 June 2026 the Dahua Product Security Incident Response Team (Dahua PSIRT) published advisory <strong>DHCC-SA-202606-001<\/strong> covering three vulnerabilities in some Dahua products. The most serious, <strong>CVE-2026-29116<\/strong>, scores 8.7 under CVSS v4.0 and lets an attacker with no credentials force the device to reboot by sending a crafted packet. What matters for Saudi sites is the scope: this flaw is not limited to cameras but also reaches NVRs, XVRs, video intercom units and access control devices.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9c8a07 elementor-widget elementor-widget-text-editor\" data-id=\"d9c8a07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key points<\/h2><ul><li>Three CVEs: CVE-2026-29114, CVE-2026-29115 and CVE-2026-29116.<\/li><li>The most serious, CVE-2026-29116 (8.7), is an unauthenticated denial of service that reboots the device.<\/li><li>Affected: parts of the IPC, SD, NVR, XVR, EVS, VTO, VTH, ASI and TPC categories; the exact model list is linked from the advisory.<\/li><li>Dahua defines affected versions by firmware build date; the fix is an update from the official download center, or a cloud upgrade where supported.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-875fcbd elementor-widget elementor-widget-text-editor\" data-id=\"875fcbd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What are the three vulnerabilities?<\/h2><table><thead><tr><th>CVE<\/th><th>Description, per Dahua<\/th><th>Score (CVSS v4.0)<\/th><th>Affected categories<\/th><th>Affected builds<\/th><\/tr><\/thead><tbody><tr><td>CVE-2026-29114<\/td><td>An attacker may obtain the device&#8217;s CA root certificate; if that CA is trusted on client systems, fraudulent certificates could be issued that those clients trust<\/td><td>2.3<\/td><td>Part of IPC<\/td><td>Build date before 15 April 2026<\/td><\/tr><tr><td>CVE-2026-29115<\/td><td>An authenticated attacker sends a crafted packet that makes the system reboot unexpectedly (denial of service)<\/td><td>6.9<\/td><td>Part of IPC, SD<\/td><td>Build date before 26 March 2026<\/td><\/tr><tr><td>CVE-2026-29116<\/td><td>An unauthenticated attacker sends a crafted packet that makes the system reboot unexpectedly (denial of service)<\/td><td>8.7<\/td><td>Part of IPC, SD, NVR, XVR, EVS, VTO, VTH, ASI, TPC<\/td><td>Build date before 26 March 2026<\/td><\/tr><\/tbody><\/table><p>Source: Dahua advisory DHCC-SA-202606-001. Dahua notes that the build date is shown in the device web interface under Settings, System Information, Version Information.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa335a4 elementor-widget elementor-widget-text-editor\" data-id=\"fa335a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why a reboot flaw matters in CCTV<\/h2><p>A reboot bug can look minor next to flaws that hand over control of a device, but in a surveillance system it means gaps in recording. A camera or recorder that keeps restarting leaves minutes with no footage, which is exactly what a shop, warehouse or residential compound owner cannot afford when an incident happens. And with VTO and VTH (video intercom units) and ASI (access control terminals) on the list, the entrances themselves may be affected too.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-44fd84c elementor-widget elementor-widget-text-editor\" data-id=\"44fd84c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What it means for facilities in Saudi Arabia<\/h2><p>Dahua cameras and recorders are widely installed across the Kingdom, and many systems have not had a firmware update since commissioning. The most serious flaw needs no password, so devices exposed directly to the internet through port forwarding are the most at risk. Practical steps: list every Dahua device on site (cameras, recorders, intercoms, access units), check each build date, compare models with Dahua&#8217;s list, update, close any port forwarded to the devices from the internet, and replace direct exposure with secure remote access.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c1830c elementor-widget elementor-widget-text-editor\" data-id=\"3c1830c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-take\"><h2>AZEIDK view<\/h2><p>This is not the first time we have covered Dahua firmware: our report on <a href=\"\/en\/sa\/media-center\/dahua-cameraswarm-cctv-compromise-firmware-news-en\/\">more than 14,000 compromised Dahua devices<\/a> showed what outdated firmware and weak passwords lead to. The advice does not change: firmware updates belong in <a href=\"\/en\/sa\/media-center\/cctv-security-systems-maintenance\/\">CCTV maintenance<\/a>, with a record of each device&#8217;s version. For the Dahua range we supply see <a href=\"\/en\/sa\/media-center\/dahua-brand-cctv-saudi-arabia\/\">Dahua cameras in Saudi Arabia<\/a> and <a href=\"\/en\/sa\/media-center\/dahua-cameras-agent-saudi-arabia\/\">Dahua camera supply in Saudi Arabia<\/a>, and general hardening in <a href=\"\/en\/sa\/media-center\/cctv-hacking-protection\/\">how to protect CCTV cameras from hacking<\/a>. For complete solutions visit <a href=\"\/en\/sa\/solutions\/security-surveillance-systems\/\">security and surveillance systems<\/a>; the device audit and updates can run under our <a href=\"\/en\/sa\/services\/annual-maintenance-contracts\/\">annual maintenance contracts<\/a>, or you can <a href=\"\/en\/sa\/contact\/\">contact the AZEIDK team<\/a>.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a633687 elementor-widget elementor-widget-text-editor\" data-id=\"a633687\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"azn-sources\"><h2>Sources<\/h2><ol><li><a href=\"https:\/\/www.dahuasecurity.com\/about-dahua\/trust-center\/dahua-psirt\/dhcc-sa-202606-001:-security-advisory-%E2%80%93-vulnerabilities-found-in-some-dahua-products\" rel=\"nofollow noopener\" target=\"_blank\">DHCC-SA-202606-001: Security Advisory, Vulnerabilities found in some Dahua products<\/a>, Dahua, 10 June 2026<\/li><\/ol><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Dahua disclosed three vulnerabilities on 10 June 2026; CVE-2026-29116 scores 8.7 and reaches cameras, NVRs, XVRs and intercoms. Affected categories and update steps.<\/p>\n","protected":false},"author":0,"featured_media":29532,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[258],"tags":[],"azeidk_region":[223],"class_list":["post-29538","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29538"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29538\/revisions"}],"predecessor-version":[{"id":29545,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29538\/revisions\/29545"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29532"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29538"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}