{"id":29403,"date":"2026-11-22T18:41:23","date_gmt":"2026-11-22T15:41:23","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-22T18:41:28","modified_gmt":"2026-11-22T15:41:28","slug":"smoke-detector-placement-ceiling-void","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/smoke-detector-placement-ceiling-void\/","title":{"rendered":"Smoke Detector Placement: AC Diffusers, Beams, High Ceilings, Ceiling Voids and Raised Floors"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"29403\" class=\"elementor elementor-29403 elementor-29402 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e7489d6 e-con-full az-el-article e-flex e-con e-parent\" data-id=\"e7489d6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5817a76 elementor-widget elementor-widget-text-editor\" data-id=\"5817a76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Smoke detector placement<\/strong> follows the smoke. Smoke rises to the ceiling and spreads beneath it, so a spot-type detector goes on the ceiling or high on the wall in that path, away from the air thrown by supply diffusers, and in every concealed space that holds combustibles and falls under the required coverage, such as the void above a suspended ceiling or below a raised floor.<\/p>\n<p>Detector quantities and spacing are covered in our guide to <a href=\"\/en\/sa\/media-center\/smoke-heat-detector-spacing-calculation\/\">smoke and heat detector spacing calculation<\/a>. This article answers where the detector goes, and where it must not.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5edc7 elementor-widget elementor-widget-text-editor\" data-id=\"ef5edc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>NFPA 72 allows a spot-type smoke detector on the ceiling, or on the sidewall with the top of the detector within 300 mm (12 in) of the ceiling.<\/li><li>Keep detectors away from HVAC openings and never in the direct air stream. The Honeywell summary of BS 5839-1:2017 gives at least 1 m; confirm the value in the edition your project adopts.<\/li><li>Total coverage under NFPA 72 includes spaces above suspended ceilings, with specific exceptions for certain noncombustible or small concealed spaces.<\/li><li>According to the Honeywell summary of BS 5839-1:2017, voids less than 800 mm deep generally do not need detectors unless the fire risk assessment says otherwise.<\/li><li>Every detector hidden above a ceiling or below a floor needs a remote indicator, such as the Context Plus BF318, and a marked access tile.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64bab49 elementor-widget elementor-widget-text-editor\" data-id=\"64bab49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Smoke detector placement: where do you start?<\/h2>\n<p>In Saudi Arabia the project is governed by the Saudi Fire Code, SBC 801, whose 2024 edition has been mandatory since 30 June 2025. The detailed detector locations usually come from NFPA 72 as the technical reference the designer adopts, or from BS 5839-1 where the project specification calls for it. Confirm the edition with the code&#8217;s reference standards and Civil Defense, and do not mix the two standards on one drawing.<\/p>\n<p>A note on editions: the BS 5839-1 values in this article come from the Notifier UK guide published by Honeywell, which summarises the 2017 edition; they are not quoted from the standard itself. On 30 April 2025 BSI announced publication of BS 5839-1:2025 as a revision of the 2017 edition. We have not reviewed the new text, so check every value against the edition your project specification adopts.<\/p>\n<p>The basic NFPA 72 rule, as listed in the fire alarm shop drawing checklist of the Tennessee State Fire Marshal&#8217;s Office (revised April 2025): a spot-type smoke detector is mounted on the ceiling, or on the sidewall between the ceiling and 300 mm below it, measured to the top of the detector. NFPA 72 also requires the design to account for ceiling shape and height, contents and ventilation.<\/p>\n<p>For the <a href=\"\/en\/sa\/solutions\/fire-alarm-systems\/\">fire alarm systems<\/a> AZEIDK designs, supplies and installs, this review starts on the coordinated reflected ceiling plan (RCP) before the fire alarm drawings are approved, because moving a detector after the ceiling is installed is far harder than moving it on paper.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be9e71b elementor-widget elementor-widget-text-editor\" data-id=\"be9e71b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How far should a smoke detector be from an AC diffuser?<\/h2>\n<p>Supply diffusers spoil more detector locations in Saudi offices, hotels and malls than anything else. Their air pushes smoke away and dilutes it and carries dust into the chamber, raising false alarm risk.<\/p>\n<ul><li><strong>BS 5839-1:2017 (per the Honeywell summary):<\/strong> at least 1 m between a smoke detector and an air conditioning inlet or outlet, and further if possible.<\/li><li><strong>NFPA 72:<\/strong> a March 2005 Security Sales &amp; Integration article, citing the NFPA 72-2002 handbook (section 5.7.4), gave 3 ft (0.9 m) between detectors and air registers or diffusers. That figure belongs to an old edition and we have not verified the equivalent clause in current editions, so do not treat it as a requirement until you have checked your adopted edition.<\/li><\/ul>\n<p>In practice, take 1 m from supply and return openings unless your adopted edition says otherwise, and watch the throw of four-way diffusers.<\/p>\n<p>Where airflow is high, NFPA 72 adjusts smoke detector spacing from a dedicated table first; the table is not to be used for under-floor or above-ceiling spaces. The phrase &#8220;unaffected by wind&#8221; in the datasheet of the <a href=\"\/en\/sa\/products\/addressable-optical-smoke-detector-55000-685imc\/\">Context Plus 55000-685IMC<\/a> optical detector means the sensor reading does not drift with air speed. It does not mean smoke will reach it inside the throw.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-795bf7d elementor-widget elementor-widget-text-editor\" data-id=\"795bf7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Beams, walls and sloped ceilings: where exactly does the detector go?<\/h2>\n<p>NFPA 72 spacing for beams, joists and peaked ceilings is in our <a href=\"\/en\/sa\/media-center\/smoke-heat-detector-spacing-calculation\/\">detector spacing guide<\/a>. Here we cover the detector position itself:<\/p>\n<ul><li><strong>Between beams:<\/strong> a deep beam traps smoke in the pocket where the fire starts. BS 5839-1:2017 treats a beam deeper than 10% of the ceiling height as a wall, so each pocket needs its own coverage. Where the beam is under 10% but deeper than 250 mm, keep the detector at least 500 mm from it.<\/li><li><strong>Near obstructions:<\/strong> the same guide says to keep 500 mm from an obstruction such as a duct or cable tray near the ceiling; obstructions under 250 mm deep need twice their depth.<\/li><li><strong>Near walls:<\/strong> under BS 5839-1:2017 a detector on a flat ceiling sits at least 0.5 m from the wall. NFPA 72 allows wall mounting within 300 mm of the ceiling. Never put it in the wall-ceiling corner.<\/li><li><strong>Sloped and peaked ceilings:<\/strong> BS 5839-1:2017 places a row of smoke detectors within 600 mm vertically of the apex. Under NFPA 72 the first row is measured horizontally from the peak, as shown in the spacing guide.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5389de elementor-widget elementor-widget-text-editor\" data-id=\"b5389de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>High ceilings: why smoke sometimes never reaches the detector<\/h2>\n<p>In atriums, halls and warehouses, smoke can cool and stall below the ceiling. NFPA 72 calls this stratification. Its annex suggests detectors on sidewalls or below the ceiling, and beam detectors at different levels in high spaces.<\/p>\n<p>Height limits differ by standard. NFPA 72 applies its spot-type smoke detector spacing up to a 12.2 m (40 ft) ceiling, while the BS 5839-1:2017 table limits a point smoke detector to EN 54-7 to 10.5 m. Above that, designers usually move to beam detectors such as the <a href=\"\/en\/sa\/media-center\/context-plus-reflective-beam-detectors\/\">Context Plus reflective beam detectors<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16c1a48 elementor-widget elementor-widget-text-editor\" data-id=\"16c1a48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>When do you need detectors above a suspended ceiling?<\/h2>\n<p>Coverage and void contents decide this, not the ceiling alone. Under NFPA 72, total coverage includes rooms, halls, storage areas, basements, attics, spaces above suspended ceilings, closets, elevator shafts and enclosed stairs. NFPA&#8217;s revision reports for the 2025 edition carry these related rules:<\/p>\n<ul><li>An inaccessible area built of, or containing, combustible material is to be made accessible and provided with detection.<\/li><li>Detectors are not required in a combustible concealed space where the ceiling is attached directly to the underside of the supporting beams, where the space is entirely filled with noncombustible insulation, or where facing studs or solid joists are less than 150 mm apart.<\/li><li>Where the space above a suspended ceiling is used as a return air plenum under NFPA 90A, detection is required in one of two ways: detectors in the plenum per the relevant clause, or a detector at each connection from the plenum to the central air handling unit.<\/li><\/ul>\n<p>Under BS 5839-1:2017, voids less than 800 mm deep generally need no detectors unless the fire risk assessment says otherwise. Where a detector is fitted in a void, its sensing element sits within the top 10% of the void depth or the top 125 mm, whichever is greater.<\/p>\n<p>NFPA 72 does not accept a duct detector as a substitute for open area detection; see our article on the <a href=\"\/en\/sa\/media-center\/duct-smoke-detector-context-plus-53546\/\">duct smoke detector<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c58f76 elementor-widget elementor-widget-text-editor\" data-id=\"0c58f76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Detectors below raised floors<\/h2>\n<p>Raised floors in server and control rooms carry cables, a hidden fire load. The same logic applies: coverage, contents and depth decide whether detectors are needed. If they are:<\/p>\n<ul><li>Coordinate each detector with cable trays so it stays reachable.<\/li><li>Mark the tile above the detector, and record its address on the as-built drawing.<\/li><li>If the void distributes conditioned air, follow the manufacturer&#8217;s instructions and the detector&#8217;s listing for air velocity, because the NFPA 72 airflow spacing table is not used for these spaces.<\/li><li>Connect the detector to a remote indicator visible in the same room.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f3e245 elementor-widget elementor-widget-text-editor\" data-id=\"8f3e245\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Remote indicators for concealed detectors<\/h2>\n<p>A concealed detector needs a visible remote indicator. The <a href=\"\/en\/sa\/products\/remote-led-indicator-bf318\/\">Context Plus BF318 remote LED indicator<\/a> is designed for hidden or out-of-sight detectors. It has a high-intensity wide-angle red LED and a write-on label, and fits 16 mm surface or flush back boxes.<\/p>\n<p>From the datasheets: the 55000-685IMC addressable detector has +R and -R remote indicator terminals, with a maximum remote LED current of 5 mA. The <a href=\"\/en\/sa\/products\/series-65a-ul-conventional-smoke-detectors-55000-326imc-and-55000-226imc\/\">Series 65A UL conventional detectors<\/a> have an R- output current-limited to 17 mA, and the catalogue notes that a current-limiting series resistor may be required with a remote indicator. For what the detector&#8217;s own LED means, see <a href=\"\/en\/sa\/media-center\/smoke-detector-red-light\/\">smoke detector red light<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1702ed elementor-widget elementor-widget-text-editor\" data-id=\"e1702ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Quick reference: where to put a smoke detector and where to avoid<\/h2>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Location<\/th><th>Requirement<\/th><th>Reference<\/th><\/tr><\/thead><tbody><tr><td>Ceiling or wall<\/td><td>On the ceiling, or on the wall with the detector top within 300 mm of the ceiling<\/td><td>NFPA 72<\/td><\/tr><tr><td>Near HVAC openings<\/td><td>At least 1 m, and out of the air throw<\/td><td>BS 5839-1:2017 (Honeywell summary)<\/td><\/tr><tr><td>Between deep beams<\/td><td>Each pocket covered as a separate area where the beam exceeds 10% of ceiling height<\/td><td>BS 5839-1:2017; NFPA 72 spacing in the spacing guide<\/td><\/tr><tr><td>High ceiling<\/td><td>Spot detectors up to 12.2 m (NFPA) or 10.5 m (BS), then beam detectors or detectors at lower levels<\/td><td>NFPA 72; BS 5839-1:2017<\/td><\/tr><tr><td>Above suspended ceiling<\/td><td>Part of total coverage, with defined exceptions<\/td><td>NFPA 72<\/td><\/tr><tr><td>Void under 800 mm deep<\/td><td>Generally not required unless the risk assessment says otherwise<\/td><td>BS 5839-1:2017<\/td><\/tr><tr><td>Concealed detector<\/td><td>Visible remote indicator and marked access tile<\/td><td>Context Plus datasheets<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a79c6c0 elementor-widget elementor-widget-text-editor\" data-id=\"a79c6c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Common placement mistakes on drawings<\/h2>\n<ul><li>Laying out detectors before diffuser and light positions are fixed.<\/li><li>Leaving a cable-packed ceiling void undecided when the specification calls for total coverage.<\/li><li>Installing a detector in a ceiling or floor void with no remote indicator and no tile marking.<\/li><li>Relying on a duct detector instead of detection in a void used as a return air plenum.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5093b8 elementor-widget elementor-widget-text-editor\" data-id=\"c5093b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently asked questions<\/h2>\n<div class=\"az-faq\"><details class=\"az-faq__item\"><summary><h3>What is the best location for a smoke detector in a room?<\/h3><\/summary><p>On the ceiling, in the path of smoke spread, away from HVAC openings (at least 1 m under BS 5839-1:2017) and clear of obstructions near the ceiling. NFPA 72 also allows the wall if the detector top is within 300 mm of the ceiling.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>How far should a smoke detector be from an AC vent?<\/h3><\/summary><p>Above all, it must never sit in the direct air stream. The Honeywell summary of BS 5839-1:2017 gives at least 1 m from supply and return openings; confirm the value in your adopted edition.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Is a smoke detector required above a suspended ceiling?<\/h3><\/summary><p>For total coverage under NFPA 72, yes, apart from defined exceptions. Under BS 5839-1:2017 it is generally not required where the void is less than 800 mm deep, unless the risk assessment says otherwise.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>Do I need detectors under the raised floor of a server room?<\/h3><\/summary><p>The required coverage, the contents and depth of the void, and the project requirements decide. If fitted, they need remote indicators and coordination with cable trays.<\/p><\/details><details class=\"az-faq__item\"><summary><h3>What does a smoke detector remote indicator do?<\/h3><\/summary><p>It shows the alarm of a detector hidden above a ceiling or below a floor, so the team finds it at once. A unit such as the BF318 is mounted on a visible wall or ceiling.<\/p><\/details><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cbe459 elementor-widget elementor-widget-text-editor\" data-id=\"1cbe459\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Conclusion<\/h2>\n<p>Detector location is decided on the coordinated ceiling plan: smoke path, AC throw, void contents and the governing standard. Settling these on paper cuts false alarms and handover snags.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e216f9 elementor-widget elementor-widget-text-editor\" data-id=\"9e216f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Reviewing a detector layout before approval?<\/strong> Send us the ceiling plan, diffuser locations and required coverage, and we will review detector positions and propose Context Plus detectors and remote indicators with datasheets. <a href=\"\/en\/sa\/contact\/\">Talk to the AZEIDK team<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ba57b1 elementor-widget elementor-widget-text-editor\" data-id=\"2ba57b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/72\/72_A2024_SIG_IDS_FD_FRreport.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 72 First Draft Report, Initiating Devices (SIG-IDS)<\/a> (NFPA, 2025 edition cycle); <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/72\/72_A2024_SIG_IDS_SD_SRreport.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 72 Second Draft Report, Initiating Devices (SIG-IDS)<\/a> (NFPA); <a href=\"https:\/\/www.tn.gov\/content\/dam\/tn\/commerce\/documents\/fire_prevention\/posts\/AlarmShopDrawings.pdf\" rel=\"noopener\" target=\"_blank\">2021 Fire Alarm Shop Drawings<\/a> (Tennessee State Fire Marshal&#8217;s Office, revised April 2025); <a href=\"https:\/\/buildings.honeywell.com\/content\/dam\/hbtbt\/en\/documents\/downloads\/NotifierUK_Black-Book-2021.pdf\" rel=\"noopener\" target=\"_blank\">Notifier UK Black Book 2021<\/a> (Honeywell, summary of BS 5839-1:2017); <a href=\"https:\/\/www.bsigroup.com\/en-GB\/insights-and-media\/media-centre\/press-releases\/2025\/april\/bsi-announces-updated-fire-safety-standard-for-fire-alarm-systems-for-non-domestic-premises\" rel=\"noopener\" target=\"_blank\">BSI announces updated fire safety standard for fire alarm systems<\/a> (BSI, 30 April 2025); <a href=\"https:\/\/www.securitysales.com\/news\/avoiding-smoke-detector-installation-problems\/44216\/\" rel=\"noopener\" target=\"_blank\">Avoiding Smoke Detector Installation Problems<\/a> (Security Sales &amp; Integration, March 2005, on NFPA 72-2002); <a href=\"https:\/\/www.ecmag.com\/magazine\/articles\/article-detail\/integrated-systems-special-applications-partial-selective-and-other-coverage-requirements\" rel=\"noopener\" target=\"_blank\">Special applications: partial, selective and other coverage requirements<\/a> (Electrical Contractor, March 2021); <a href=\"https:\/\/www.ecmag.com\/magazine\/articles\/article-detail\/smoke-detector-placement-know-what-is-expected-of-you-and-the-installed-hardware\" rel=\"noopener\" target=\"_blank\">Smoke Detector Placement<\/a> (Electrical Contractor, May 2025); Context Plus datasheets for 55000-685IMC, Series 65A and BF318 published on the product pages.<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Smoke detector placement per NFPA 72 and BS 5839-1: AC diffuser and beam clearances, high ceilings, and when ceiling voids and raised floors need detectors.<\/p>\n","protected":false},"author":0,"featured_media":29395,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,323,322],"tags":[],"azeidk_region":[223],"class_list":["post-29403","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-systems-guides-en","category-systems-guides-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=29403"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29403\/revisions"}],"predecessor-version":[{"id":29439,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/29403\/revisions\/29439"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/29395"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=29403"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=29403"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=29403"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=29403"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}