{"id":28828,"date":"2026-11-21T17:08:48","date_gmt":"2026-11-21T14:08:48","guid":{"rendered":"https:\/\/azeidkgroup.com\/sa\/media-center\/"},"modified":"2026-11-21T17:08:59","modified_gmt":"2026-11-21T14:08:59","slug":"clean-agent-system-listings-ul-2166-ul-2127-fm-5600","status":"publish","type":"post","link":"https:\/\/azeidkgroup.com\/en\/sa\/media-center\/clean-agent-system-listings-ul-2166-ul-2127-fm-5600\/","title":{"rendered":"Clean Agent System Approval: UL 2166, UL 2127, FM 5600 and ISO 14520, and What Saudi Consultants Ask For"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28828\" class=\"elementor elementor-28828 elementor-28827 elementor-bc-flex-widget\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7cc54ec e-con-full az-el-article e-flex e-con e-parent\" data-id=\"7cc54ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b57fabc elementor-widget elementor-widget-text-editor\" data-id=\"b57fabc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-intro\"><strong>Clean agent system approval<\/strong> is not a certificate on the cylinder alone. A listing or approval covers the complete system as the laboratory tested it: the agent, cylinders, valves, piping, nozzles, the hydraulic flow calculation method and the design manual. Under the US laboratory standards, halocarbon systems are tested to UL 2166, inert gas systems to UL 2127, and both types to FM 5600. NFPA 2001 and ISO 14520 are design, installation and maintenance standards, not product certifications.<\/p>\n<p>This article separates the listing standard from the design standard and sets out what a consultant in Saudi Arabia checks in a clean agent submittal for a server, electrical or archive room. AZEIDK GROUP supplies clean agent systems within its <a href=\"\/en\/sa\/solutions\/special-fire-suppression-systems\/\">special fire suppression systems<\/a>, including the <a href=\"\/en\/sa\/products\/sffeco-1230-clean-agent-fire-suppression-system\/\">SFFECO 1230 system<\/a> and the <a href=\"\/en\/sa\/products\/context-plus-227-hfc-227ea-clean-agent\/\">Context Plus 227 system<\/a>. The approvals mentioned here belong to the manufacturers of those systems.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5e8b12 elementor-widget elementor-widget-text-editor\" data-id=\"c5e8b12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-keybox\"><h2>Key takeaways<\/h2><ul><li>UL 2166 covers halocarbon clean agent system units such as HFC-227ea and FK-5-1-12.<\/li><li>UL 2127 covers inert gas clean agent system units such as IG-541, IG-55 and IG-100.<\/li><li>FM 5600 (dated January 2023) covers both types and does not approve incomplete systems.<\/li><li>NFPA 2001 (2025 edition) and ISO 14520 are design standards and do not certify a product.<\/li><li>Mixing cylinders, valves and nozzles from different listed systems takes the installation outside its listing.<\/li><\/ul><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59b3b53 elementor-widget elementor-widget-text-editor\" data-id=\"59b3b53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Listing standard or design standard?<\/h2>\n<p>Many submittals mix two kinds of reference. The first is a test standard that UL or FM Approvals uses to decide whether a product goes into its directory. The second is the standard the designer and contractor use to size the agent quantity, set the discharge time and install and test the system.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Reference<\/th><th>Type<\/th><th>What it covers<\/th><\/tr><\/thead><tbody>\n<tr><td>UL 2166<\/td><td>Product listing standard (UL)<\/td><td>Construction and operation of halocarbon clean agent extinguishing system units<\/td><\/tr>\n<tr><td>UL 2127<\/td><td>Product listing standard (UL)<\/td><td>Construction and operation of inert gas clean agent extinguishing system units; Edition 4 published 14 March 2024<\/td><\/tr>\n<tr><td>FM 5600<\/td><td>Approval standard (FM Approvals)<\/td><td>Vaporizing liquid and inert gas clean agent systems for total flooding<\/td><\/tr>\n<tr><td>NFPA 2001<\/td><td>Design, installation and maintenance standard<\/td><td>Total flooding and local application clean agent systems, engineered and pre-engineered<\/td><\/tr>\n<tr><td>ISO 14520<\/td><td>International design standard series<\/td><td>Part 1 general requirements (4th edition, February 2023) plus a separate part for each agent<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>In practice, &#8220;complies with NFPA 2001&#8221; on a datasheet does not mean the system is listed. The system itself must appear in the UL or FM directory, and it is then designed and installed to NFPA 2001 or ISO 14520 as the consultant specifies. For the general difference between the two marks, see <a href=\"\/en\/sa\/media-center\/ul-listed-vs-fm-approved\/\">UL Listed vs FM Approved<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5d5a28 elementor-widget elementor-widget-text-editor\" data-id=\"a5d5a28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What does UL 2166 test in a halocarbon system?<\/h2>\n<p>As published, the scope of UL 2166 covers the construction and operation of halocarbon clean agent extinguishing system units intended to be installed, inspected, tested and maintained to NFPA 2001. HFC-227ea (sold as FM-200) and FK-5-1-12 fall in this group.<\/p>\n<p>The standard also covers automatic extinguisher units, but it states that these units are not a substitute for engineered or pre-engineered systems and must not be combined to protect a hazard larger than the manufacturer allows for one unit. Consultants check this when several standalone units are offered in place of a piped system.<\/p>\n<p>The published historical edition of UL 2166 requires a design manual for engineered systems, evaluates the flow calculation method in a dedicated test, and runs Class A fire tests (wood crib and plastics) and Class B fire tests with heptane. That is why a listing is tied to the manufacturer&#8217;s design manual and calculation software.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-627fc77 elementor-widget elementor-widget-text-editor\" data-id=\"627fc77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>UL 2127 for inert gas systems<\/h2>\n<p>UL 2127 is the counterpart for inert gas systems such as IG-541, IG-55 and IG-100. Edition 4 was published on 14 March 2024, and its scope is the construction and operation of inert gas clean agent system units installed and maintained to NFPA 2001. These systems store gas at high pressure and work by lowering oxygen concentration, so their cylinders, valves and calculation method differ from halocarbon systems. A UL 2166 listing cannot be submitted for an inert gas system, or the other way round.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7274cc elementor-widget elementor-widget-text-editor\" data-id=\"d7274cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What FM 5600 covers<\/h2>\n<p>FM Approvals Class 5600 is the approval standard for clean agent extinguishing systems; the version published on the FM Approvals website is dated January 2023. It covers vaporizing liquid (halocarbon) and inert gas systems for total flooding, under Class 5611 (inert gas extinguishing systems), 5612 (liquefied gas extinguishing systems) and 5613 (clean agents).<\/p>\n<ul>\n<li><strong>System components in scope:<\/strong> agent storage containers, discharge control valves, lockout valves where required, piping and discharge nozzles.<\/li>\n<li><strong>Detection and release controls:<\/strong> required for automatic operation and must be compatible and certified, but they sit outside the scope of FM 5600.<\/li>\n<li><strong>Complete systems only:<\/strong> systems are submitted with design, installation, operation and maintenance instructions, and the standard states that incomplete systems shall not be certified.<\/li>\n<li><strong>Purchased devices:<\/strong> items such as releases and timers are submitted by the system manufacturer for evaluation as part of the system, even if they are already certified on their own.<\/li>\n<li><strong>Design instructions:<\/strong> evaluated against NFPA 2001 and relevant local standards; the standard includes Class A and B fire tests and verification of the flow calculation method.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db1005a elementor-widget elementor-widget-text-editor\" data-id=\"db1005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Where NFPA 2001 and ISO 14520 fit<\/h2>\n<p>NFPA 2001 (2025 edition) sets design concentration, discharge time, hold time, enclosure integrity and safety in occupied spaces; see our <a href=\"\/en\/sa\/media-center\/nfpa-2001-clean-agent-standard-guide\/\">NFPA 2001 guide<\/a>. ISO 14520 is an international series with a general Part 1 and agent-specific parts, such as Part 5 for FK-5-1-12 and Part 15 for IG-541. Part 1 states that it is not intended to indicate approval of the extinguishants it lists by the appropriate authorities.<\/p>\n<p>Neither standard certifies a product. The designer applies them to a listed system and takes the extinguishing concentration, safety factor and piping limits from that listed system&#8217;s design manual.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65e5fe0 elementor-widget elementor-widget-text-editor\" data-id=\"65e5fe0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Why mixing components voids clean agent system approval<\/h2>\n<p>The tests were run on one defined combination. A cylinder from one system, a valve from another and nozzles from a third supplier make a system nobody tested. The effect shows up in the hydraulic calculation, because the software is verified only for the manufacturer&#8217;s own components, and nozzle and valve coefficients are part of the calculation.<\/p>\n<div class=\"az-table-wrap\"><table><thead><tr><th>Site situation<\/th><th>Problem<\/th><th>Action<\/th><\/tr><\/thead><tbody>\n<tr><td>Nozzles replaced with another supplier&#8217;s nozzles<\/td><td>Flow coefficient and coverage not tested within the system<\/td><td>Nozzles from the same listed system<\/td><\/tr>\n<tr><td>Agent from a source not named in the listing<\/td><td>The agent is part of the tested system<\/td><td>Fill with the agent named in the system manual<\/td><\/tr>\n<tr><td>Flow calculation in generic software<\/td><td>Software not verified for this system<\/td><td>Manufacturer&#8217;s software and listed version<\/td><\/tr>\n<tr><td>Actuator or selector valve from another system<\/td><td>Not on the system&#8217;s component list<\/td><td>Components from the same system list<\/td><\/tr>\n<tr><td>UL 2166 listing offered for an inert gas system<\/td><td>Wrong standard for the agent type<\/td><td>UL 2127 or FM 5600 for the proposed system<\/td><\/tr>\n<\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c278dd7 elementor-widget elementor-widget-text-editor\" data-id=\"c278dd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>What consultants ask for in a clean agent submittal<\/h2>\n<p>Requirements vary by consultant, but these items come up repeatedly in reviews for server, electrical and archive rooms:<\/p>\n<ol>\n<li><strong>Proof of listing:<\/strong> the system page from UL Product iQ or the FM Approval Guide with the holder name and file number, not a logo image. See <a href=\"\/en\/sa\/media-center\/verify-ul-fm-lpcb-listing-steps\/\">how to verify UL, FM and LPCB listings<\/a>.<\/li>\n<li><strong>Standard matched to agent:<\/strong> UL 2166 for halocarbons, UL 2127 for inert gases, FM 5600 for either.<\/li>\n<li><strong>Datasheet for each component:<\/strong> cylinder, valve, actuator, nozzle and pressure switch, with model numbers matching the system listing.<\/li>\n<li><strong>Design and installation manual:<\/strong> the revision covered by the listing.<\/li>\n<li><strong>Hydraulic calculation:<\/strong> in the manufacturer&#8217;s software, with agent quantity per NFPA 2001 or ISO 14520 according to the design basis.<\/li>\n<li><strong>Release panel and detectors:<\/strong> a release panel compatible with the system, such as the <a href=\"\/en\/sa\/products\/context-plus-ep203-con-automatic-extinguisher-control-panel\/\">Context Plus EP203 panel<\/a> for Context Plus systems.<\/li>\n<li><strong>Room integrity:<\/strong> a door fan test plan and pressure relief venting.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b99af9 elementor-widget elementor-widget-text-editor\" data-id=\"1b99af9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Reading the approvals of the systems AZEIDK supplies<\/h2>\n<p>The approvals below are stated on AZEIDK product pages and belong to the manufacturers, not to AZEIDK:<\/p>\n<ul>\n<li><strong><a href=\"\/en\/sa\/products\/sffeco-1230-clean-agent-fire-suppression-system\/\">SFFECO 1230<\/a>:<\/strong> FK-5-1-12 agent; the page states UL 2166, FM 5600 and design to NFPA 2001. Details in our <a href=\"\/en\/sa\/media-center\/sffeco-1230-clean-agent-system-saudi-en\/\">SFFECO 1230 article<\/a>.<\/li>\n<li><strong><a href=\"\/en\/sa\/products\/context-plus-227-hfc-227ea-clean-agent\/\">Context Plus 227<\/a>:<\/strong> HFC-227ea agent; the page states UL Listed, FM Approved and compliance with NFPA 2001.<\/li>\n<li><strong><a href=\"\/en\/sa\/products\/american-afc-fm-200-fire-suppression-system\/\">American Fire Control FM-200 system<\/a>:<\/strong> the page states a UL listing with its file number and FM approval, and design with approved hydraulic calculation software and manufacturer data.<\/li>\n<\/ul>\n<p>Before supply, the <a href=\"\/en\/sa\/services\/technical-supply-of-fire-safety-systems\/\">technical supply<\/a> team checks that the file number on the datasheet appears in the certifier&#8217;s directory under the same manufacturer, and that every item on the bill of materials belongs to the listed system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-412f868 elementor-widget elementor-widget-text-editor\" data-id=\"412f868\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Does a UL or FM approval replace Saudi requirements?<\/h2>\n<p>No. A laboratory listing proves performance in testing; it does not replace Saudi requirements. The SASO Technical Regulation for Fire Control Materials and Equipment covers extinguishing equipment, devices, substances and parts, and requires a Certificate of Conformity before they are placed on the market, while fire alarm and firefighting systems are excluded from its scope and referred to the requirements of the Saudi fire protection code. Its annex lists Saudi standards adopted from the ISO 14520 series for several agents, including SASO-ISO-14520-5 for FK-5-1-12 and SASO-ISO-14520-15 for IG-541. Check the scope of each item on SABER before shipping; the steps are in <a href=\"\/en\/sa\/media-center\/saber-conformity-certificate-fire-equipment-steps\/\">SABER conformity certificate for fire equipment<\/a>. Project approval by Civil Defense is a separate track, supported by our <a href=\"\/en\/sa\/services\/civil-defense-approval-support\/\">Civil Defense approval support<\/a> team.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1537241 elementor-widget elementor-widget-text-editor\" data-id=\"1537241\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-faq\"><h2>Frequently asked questions<\/h2>\n<details class=\"az-faq__item\"><summary><h3>What is UL 2166?<\/h3><\/summary><p>The UL standard for halocarbon clean agent extinguishing system units such as FM-200 and FK-5-1-12 systems, which are installed to NFPA 2001.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is the difference between UL 2166 and UL 2127?<\/h3><\/summary><p>UL 2166 is for halocarbon agents; UL 2127 is for inert gases such as IG-541 and IG-55. One cannot stand in for the other.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Is NFPA 2001 a certification?<\/h3><\/summary><p>No. NFPA 2001 is a design, installation, testing and maintenance standard; listing comes from a body such as UL or FM Approvals.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>What is FM 5600?<\/h3><\/summary><p>The FM Approvals standard for halocarbon and inert gas clean agent systems. It tests the complete system and does not approve incomplete systems.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>Can I fit another brand&#8217;s nozzles or cylinders on an FM-200 system?<\/h3><\/summary><p>Not unless they are on the component list of the same listed system, because the listing and the flow calculation are based on the manufacturer&#8217;s components.<\/p><\/details>\n<details class=\"az-faq__item\"><summary><h3>How does ISO 14520 relate to gas suppression in Saudi Arabia?<\/h3><\/summary><p>ISO 14520 is an international design series, and the annex of the SASO regulation for fire control equipment lists Saudi standards adopted from it for several agents.<\/p><\/details>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1027f1 elementor-widget elementor-widget-text-editor\" data-id=\"c1027f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"az-cta\"><strong>Reviewing a clean agent submittal for a server or electrical room?<\/strong> Send the agent type, room dimensions and the consultant&#8217;s requirements, and AZEIDK will propose the matching listed system and its documents. <a href=\"\/en\/sa\/contact\/\">Contact AZEIDK<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc56bfa elementor-widget elementor-widget-text-editor\" data-id=\"fc56bfa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"az-source\"><strong>References:<\/strong> <a href=\"https:\/\/www.osha.gov\/nationally-recognized-testing-laboratory-program\/fm\" rel=\"noopener\" target=\"_blank\">FM Approvals, NRTL Program<\/a> (OSHA), <a href=\"https:\/\/www.fmapprovals.com\/-\/media\/Feature\/Approval-Standards\/5600-pdf.pdf\" rel=\"noopener\" target=\"_blank\">Approval Standard for Clean Agent Extinguishing Systems, Class 5600<\/a> (FM Approvals), <a href=\"https:\/\/law.resource.org\/pub\/us\/cfr\/ibr\/inc\/ul\/ul.s2166.1.2001.pdf\" rel=\"noopener\" target=\"_blank\">UL 2166 (historical edition)<\/a>, <a href=\"https:\/\/webstore.ansi.org\/standards\/ul\/ul2127ed2024\" rel=\"noopener\" target=\"_blank\">UL 2127 Ed. 4 (2024)<\/a> (ANSI Webstore), <a href=\"https:\/\/webstore.ansi.org\/standards\/nfpa\/nfpa20012025\" rel=\"noopener\" target=\"_blank\">NFPA 2001-2025<\/a> (ANSI Webstore), <a href=\"https:\/\/www.iso.org\/standard\/79444.html\" rel=\"noopener\" target=\"_blank\">ISO 14520-1:2023<\/a> (ISO), <a href=\"https:\/\/saso.gov.sa\/en\/Laws-And-Regulations\/Technical_regulations\/Documents\/TR%20-%20Fire%20Control%20Materials%20and%20Equipment.pdf\" rel=\"noopener\" target=\"_blank\">Technical Regulation for Fire Control Materials and Equipment<\/a> (SASO)<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Clean agent system approval explained: UL 2166, UL 2127 and FM 5600 listings vs NFPA 2001 and ISO 14520 design standards, and what Saudi consultants check.<\/p>\n","protected":false},"author":0,"featured_media":28813,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221,321,320],"tags":[],"azeidk_region":[223],"class_list":["post-28828","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-azeidk-articles","category-codes-certifications-en","category-codes-certifications-ar"],"acf":[],"_links":{"self":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28828","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/comments?post=28828"}],"version-history":[{"count":1,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28828\/revisions"}],"predecessor-version":[{"id":28859,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/posts\/28828\/revisions\/28859"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media\/28813"}],"wp:attachment":[{"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/media?parent=28828"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/categories?post=28828"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/tags?post=28828"},{"taxonomy":"azeidk_region","embeddable":true,"href":"https:\/\/azeidkgroup.com\/en\/wp-json\/wp\/v2\/azeidk_region?post=28828"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}